Siemens 7KT1670 SENTRON PAC1100 Three-Phase Power Meter

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:7KT1670
  • HS: 9028301300
Availability:In Stock
Price Fluctuations
zhongpingtech

The Siemens 7KT1670 SENTRON PAC1600 is a sophisticated three-phase power meter designed for precise energy measurement and monitoring in industrial and commercial applications. This device offers a robust solution for understanding energy consumption, optimizing power distribution, and ensuring system efficiency. Its key advantages lie in its accuracy, reliability, and seamless integration capabilities within broader energy management systems. The PAC1600 provides comprehensive data on active, reactive, and apparent energy, alongside critical electrical parameters.


Product Specifications


| Feature                   | Specification                                      |

| :------------------------ | :------------------------------------------------- |

| Product Brand Name        | SENTRON                                            |

| Product Designation       | Measuring instrument / Energy counter              |

| Model Number              | 7KT1670                                            |

| Voltage (L-L)             | 400 V                                              |

| Voltage (L-N)             | 230 V                                              |

| Rated Current             | 80 A                                               |

| Phases                    | Three-phase                                        |

| Energy Measurement        | Apparent, Active, Reactive                         |

| Power Supply              | Self-powered                                       |

| Mounting Type             | Standard mounting rail device                      |

| Display                   | LCD                                                |

| Protection Class (Front)  | IP40                                               |

| Protection Class (Rear)   | IP20                                               |

| Communication Interface   | S0                                                 |

| Operating Frequency       | 45 Hz - 65 Hz                                      |

| Pulse Duration            | 30 ms                                              |

| Dimensions (H x W x D)    | 92.00 x 77.00 x 55.00 mm                           |

| Net Weight                | 0.360 Kg                                           |

| Temperature Range         | -25 °C to +55 °C                                   |

| Metering Accuracy         | Acc. to IEC62053-21 and IEC62053-23                |

| Digital Inputs            | 1                                                  |

| Digital Outputs           | 2 (solid state switching)                          |


Core Features & Market Positioning


The Siemens 7KT1670 SENTRON PAC1600 positions itself as a highly reliable and accurate energy measurement solution within the SENTRON portfolio, renowned for its precision and robust performance in demanding industrial environments. Its core strength lies in the comprehensive measurement of all relevant electrical variables, providing a clear view of energy consumption and power quality. This capability differentiates it in the market, offering users detailed insights beyond simple energy counting, enabling proactive management of power distribution and plant capacity utilization. The device is designed for straightforward integration into existing automation and energy management systems, supported by Siemens' comprehensive SENTRON ecosystem, including configuration software like powerconfig. This focus on integration and advanced diagnostics underscores its value proposition for businesses seeking to enhance operational efficiency and reduce energy costs.


Key Application Scenarios


The Siemens 7KT1670 SENTRON PAC1600 is ideally suited for a wide array of applications, primarily focusing on precise energy monitoring in three-phase systems. It is extensively deployed in industrial plants for monitoring energy consumption of machinery and production lines, helping to identify areas for efficiency improvements and cost reduction. In commercial buildings, it serves to track energy usage across different zones or departments, facilitating better resource allocation and cost center accounting. It is also a valuable tool in distribution boards, providing detailed insights into the power flow for individual feeders or loads, thereby enabling better capacity planning and load management. Furthermore, its ability to measure apparent, active, and reactive energy makes it indispensable for power quality analysis and ensuring compliance with energy regulations in various sectors.


Practical System Integration Guidance


Integrating the Siemens 7KT1670 SENTRON PAC1600 into existing systems is streamlined through its communication capabilities and the support of Siemens' SENTRON software tools. The device features an S0 pulse output for basic data logging, with optional communication interfaces like RS 485 and M-Bus available on other models within the PAC1600 series, enabling seamless integration into SCADA, building management, or energy management systems. For commissioning and parameterization, Siemens offers the SENTRON powerconfig software, a PC-based tool that simplifies setup and configuration, even for multiple devices, saving significant engineering time. When establishing Modbus RTU communication, it is crucial to note that RS 485 termination with a 120 Ohm resistor at both ends of the bus cable is recommended to prevent signal reflection. Ensuring correct voltage connections and performing a temperature balance of at least two hours before connecting to the power supply are critical steps to prevent device damage.


Operation and Risk Mitigation


Operating the Siemens 7KT1670 SENTRON PAC1600 requires adherence to safety protocols typical for electrical installations. The device is designed for standard mounting rail installation and is self-powered, simplifying its setup. Its front-side IP40 protection and rear-side IP20 rating offer adequate defense against dust and accidental contact, but it should be installed in an environment protected from excessive moisture or extreme temperatures. A critical aspect of risk mitigation is ensuring proper fusing of the voltage measuring inputs to prevent equipment damage. The device’s operational voltage range for line-to-line connections is up to 400V, and line-to-neutral is up to 230V, with an operating frequency range of 45 Hz to 65 Hz. In case of any damage or fault, it is crucial to consult the equipment manual and contact Siemens for repair or replacement, avoiding the operation of compromised units to prevent potential injury or property damage.


Scalability & Long-Term Value


The Siemens 7KT1670 SENTRON PAC1600 contributes to long-term value through its integration within the broader, scalable SENTRON ecosystem. While the 7KT1670 itself is a foundational device, Siemens offers a range of SENTRON PAC measuring devices and expansion modules that allow for system growth and enhanced functionality. This scalability is further supported by Siemens' energy management software, such as SENTRON powermanager, which can be integrated with existing hardware to provide advanced data analysis, reporting, and visualization capabilities. The compatibility with these software solutions ensures that the data collected by the PAC1600 can be leveraged for continuous improvement in energy efficiency, compliance with standards like ISO 50001, and optimization of energy procurement contracts. This integrated approach ensures the device remains a valuable asset throughout a facility's evolving energy management strategy, offering a clear path towards digitalized power monitoring and IIoT integration.


Frequently Asked Questions (FAQs)


Q1: What are the primary benefits of using the Siemens 7KT1670 SENTRON PAC1600?

The 7KT1670 provides highly accurate measurement of active, reactive, and apparent energy. It offers valuable insights into power distribution and system status. Its integration capabilities simplify data analysis for energy management.


This device enhances operational efficiency by providing crucial data for optimizing plant capacity utilization. It helps in identifying potential issues and preventing peak loads, ensuring system reliability.


The SENTRON PAC1600 is designed for easy integration into existing automation and energy management systems. It supports standards like S0 and can be expanded with other communication modules for advanced data exchange.


Q2: How is the Siemens 7KT1670 SENTRON PAC1600 installed and commissioned?

Installation involves mounting the device on a standard DIN rail. Ensure correct wiring for three-phase connections according to the manual's diagrams. Always follow electrical safety guidelines during installation.


Commissioning is simplified with Siemens' SENTRON powerconfig software. This PC-based tool allows for efficient parameterization and configuration, saving time, especially for multiple device setups.


Before connecting to power, allow the device to acclimate to the ambient temperature for at least two hours to prevent condensation damage. Properly fuse the voltage measuring inputs as a safety measure.


Q3: What technical specifications define the Siemens 7KT1670 SENTRON PAC1600's performance?

This meter measures voltage up to 400V (L-L) and 230V (L-N), with a rated current of 80A. It operates across a frequency range of 45Hz to 65Hz.


It accurately captures apparent, active, and reactive energy with metering accuracy compliant to IEC standards. The LCD display provides clear readings of measured values.


The device features an IP40 front protection rating and operates reliably within a temperature range of -25°C to +55°C. It is self-powered for simplified integration.


Q4: What are the communication capabilities of the Siemens 7KT1670 SENTRON PAC1600?

The standard 7KT1670 model is equipped with an S0 pulse output for basic data transmission. This interface is suitable for direct connection to data loggers or PLC inputs.


While the 7KT1670 has S0, other models in the PAC1600 series offer optional interfaces like RS 485 and M-Bus. These allow for more advanced communication protocols for system integration.


For enhanced data exchange, integration with Siemens' SENTRON powermanager software is possible. This enables comprehensive energy data acquisition and analysis in a centralized system.


Q5: Can the Siemens 7KT1670 SENTRON PAC1600 be used for billing purposes?

The 7KT1670 is designed for energy measurement and monitoring, providing accurate data for internal analysis. For direct billing applications, official certification might be required depending on local regulations.


Some Siemens PAC devices, like the 7KT1671, feature MID certification, making them suitable for revenue metering. Always check the specific model's certification for billing accuracy requirements.


The REST API on PAC devices is generally not approved for billing purposes. It is intended for experienced users for internal applications and data visualization, not official financial reporting.


Q6: What kind of power can the Siemens 7KT1670 SENTRON PAC1600 measure?

The 7KT1670 accurately measures apparent power, which is the total power in an AC circuit. This includes both real power and reactive power.


It also precisely measures active power (real power), representing the power that does work and is consumed by the load. This is crucial for understanding energy consumption costs.


Additionally, the device measures reactive power, which is power that oscillates between the source and inductive or capacitive loads. Monitoring reactive power is important for power factor correction and system efficiency.


Q7: What are the typical applications for the Siemens 7KT1670 SENTRON PAC1600 in industrial settings?

In industrial settings, the 7KT1670 is used to monitor the energy consumption of individual machines and production lines. This helps in identifying inefficiencies and optimizing operational costs.


It aids in load management by providing real-time data on power usage, allowing for better planning and avoiding demand charges. Its comprehensive data helps in assessing plant capacity utilization.


The meter supports detailed energy analysis, including active, reactive, and apparent energy measurement. This is vital for industrial facilities that need to manage their power factor and ensure grid stability.


Q8: How does the Siemens 7KT1670 SENTRON PAC1600 contribute to energy efficiency?

By providing detailed energy consumption data, the 7KT1670 allows facilities to identify areas of high usage or waste. This enables targeted measures for reducing overall energy consumption.


The device's ability to measure reactive power helps in monitoring and improving the power factor. Optimizing the power factor can lead to reduced energy losses and lower electricity bills.


Integration with energy management software like SENTRON powermanager allows for advanced analysis and reporting. This data-driven approach supports continuous improvement in energy efficiency and compliance with standards like ISO 50001.


Q9: What is the role of SENTRON powerconfig software with the 7KT1670?

SENTRON powerconfig is a PC-based tool designed for the easy commissioning and parameterization of Siemens SENTRON devices. It significantly reduces setup time, especially when configuring multiple meters.


The software facilitates parameterization, documentation, operation, and monitoring of the 7KT1670. It offers a user-friendly interface for accessing device settings and measured values.


This tool ensures consistent device configuration and supports efficient maintenance by allowing for easy storage and retrieval of project settings. It streamlines the integration of the 7KT1670 into larger energy management systems.


Q10: What are the safety considerations when working with the Siemens 7KT1670 SENTRON PAC1600?

Always ensure that the power supply is disconnected before performing any wiring or installation. Qualified personnel should carry out electrical installations due to the presence of hazardous voltages.


The device should be installed in an environment protected from excessive moisture and dust, adhering to its IP40/IP20 ratings. Always use appropriate fuses for the voltage measuring inputs to prevent equipment damage.


Do not operate the device if it appears damaged. Refer to the equipment manual for detailed safety instructions and troubleshooting, and contact Siemens support for any repair or replacement needs.