Siemens 7KT1668 SENTRON PAC1100 Compact Single Phase Energy Meter

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:7KT1668
  • HS: 9028301300
Availability:In Stock
Price Fluctuations
zhongpingtech

The Siemens 7KT1668 SENTRON PAC1100 Compact Single Phase Energy Meter stands as a robust solution for precise energy monitoring in demanding industrial environments. This meter excels in delivering accurate measurements for single-phase loads, offering critical advantages such as high accuracy, compact design, and seamless integration capabilities. Its core features include a clear digital display for real-time data visualization, robust construction for durability, and advanced communication options for sophisticated data management. Key technical parameters include a rated voltage of 230V AC, a rated current range of 5-60A, and an accuracy class of 1.0, ensuring reliable performance for a variety of applications.


Product Specifications


| Parameter           | Specification               |

| :------------------ | :-------------------------- |

| Product Type        | Compact Single Phase Energy Meter |

| Model Number        | 7KT1668                     |

| Brand | SENTRON |

| Rated Voltage       | 230V AC                     |

| Rated Current       | 5 - 60A                     |

| Accuracy Class      | 1.0                         |

| Frequency           | 50/60 Hz                    |

| Display             | Digital LCD                 |

| Communication       | Modbus RTU (optional)       |

| Mounting            | DIN Rail                    |

| Dimensions (H x W x D) | 100mm x 75mm x 65mm         |

| Operating Temperature | -25°C to +55°C              |

| Protection Class    | IP51 (Enclosure), IP20 (Terminals) |


Core Features & Market Positioning


The Siemens 7KT1668 SENTRON PAC1100 distinguishes itself through its exceptional accuracy and compact form factor, making it ideal for applications where space is at a premium. Its positioning in the market is driven by Siemens' reputation for quality and reliability in industrial automation and energy management solutions. The optional Modbus RTU communication interface is a significant differentiator, enabling seamless integration into larger SCADA systems and energy management platforms, providing valuable data for cost allocation, load balancing, and efficiency analysis. This focus on connectivity and precise measurement underscores its value for industrial clients seeking to optimize energy consumption and operational costs.


Key Application Scenarios


This compact energy meter is exceptionally well-suited for sub-metering in commercial and industrial facilities, allowing for granular tracking of energy usage by specific equipment, production lines, or tenant spaces. Its accuracy and single-phase capability make it a prime choice for monitoring critical loads in manufacturing plants, such as individual machine tools, pumps, or conveyor systems. Furthermore, it finds application in building management systems for monitoring energy consumption in individual offices or common areas, contributing to overall energy efficiency strategies. The Siemens 7KT1668 is also relevant for renewable energy installations, such as monitoring the output of smaller solar inverters.


Practical System Integration Guidance


Integrating the Siemens 7KT1668 into existing systems is straightforward, primarily involving DIN rail mounting and direct wiring to the single-phase load. The meter features clear terminal markings for line and neutral connections, ensuring correct installation. For systems utilizing the Modbus RTU communication option, standard RS485 wiring practices should be followed, connecting the meter's communication terminals to the master controller or gateway. Configuration of the Modbus address and communication parameters is typically performed via a local interface or dedicated software, ensuring compatibility within the network architecture. Proper insulation and adherence to local electrical codes are paramount during installation to ensure safety and operational integrity.


Operation and Risk Mitigation


Operating the Siemens 7KT1668 SENTRON PAC1100 is primarily focused on reading the displayed energy consumption values and, if equipped, monitoring data transmitted via the communication interface. The meter's robust design incorporates overcurrent protection mechanisms within its rated parameters, but external circuit protection, such as fuses or circuit breakers, must be correctly sized and installed according to local regulations to prevent damage and ensure safety. Users should always ensure the power is de-energized before performing any wiring or maintenance. While the device itself has a high degree of internal fault tolerance, users should consult the Siemens documentation for specific error codes that might be displayed, although these are rare in normal operation.


Scalability & Long-Term Value


The Siemens 7KT1668 SENTRON PAC1100 offers significant long-term value through its potential for scalability and integration into evolving energy management architectures. Its compatibility with the broader Siemens SENTRON protection and switching devices allows for cohesive system design. For facilities aiming to embrace Industrial IoT (IIoT) and digital transformation, the optional Modbus RTU communication provides a vital gateway for integrating real-time energy data into cloud-based analytics platforms or advanced building management systems. This capability allows for predictive maintenance, optimized energy procurement, and sophisticated demand-side management, thereby enhancing operational efficiency and reducing long-term energy expenditure.


Frequently Asked Questions


What is the primary function of the Siemens 7KT1668 SENTRON PAC1100?

The Siemens 7KT1668 SENTRON PAC1100 is a compact single-phase energy meter designed for precise measurement of electricity consumption. It provides accurate data on energy usage for various applications. This meter is essential for sub-metering and load monitoring in industrial and commercial settings, enabling better cost allocation.


What are the key technical specifications of this energy meter?

This meter operates at 230V AC with a rated current range of 5-60A and boasts an accuracy class of 1.0. It supports 50/60 Hz frequencies and features a clear digital LCD display. The device is designed for DIN rail mounting and has dimensions of 100mm x 75mm x 65mm, with an operating temperature range of -25°C to +55°C.


Can the Siemens 7KT1668 be integrated with other systems?

Yes, the 7KT1668 offers an optional Modbus RTU communication interface, allowing seamless integration into SCADA systems and energy management platforms. This connectivity enables sophisticated data analysis and remote monitoring. Proper wiring and configuration are essential for successful integration into existing networks.


What types of applications is the Siemens 7KT1668 best suited for?

This meter is ideal for sub-metering in commercial and industrial facilities, such as monitoring individual machine tools or production lines. It's also effective for building management systems, tracking energy in specific zones or tenant spaces. Its single-phase capability makes it suitable for a wide array of localized energy monitoring needs.


How is the Siemens 7KT1668 installed in a system?

Installation involves mounting the meter on a standard DIN rail and connecting the single-phase load through its clearly marked terminals. For Modbus communication, standard RS485 wiring is required. Always ensure power is disconnected before installation and adhere to all local electrical codes for safety.


What are the benefits of using the Modbus RTU communication option?

The Modbus RTU option allows for remote data acquisition and integration into advanced energy management systems. It facilitates real-time monitoring, data logging, and analysis for optimizing energy consumption and costs. This feature enhances the meter's utility in smart building and IIoT applications.


What is the accuracy class of the Siemens 7KT1668, and why is it important?

The meter has an accuracy class of 1.0, meaning its measurement error is within 1% of the actual energy consumed. This high accuracy is crucial for precise billing, fair cost allocation, and effective energy efficiency monitoring in commercial and industrial environments. It ensures reliable data for decision-making.


What safety precautions should be taken when installing or operating this meter?

Always de-energize the circuit before installation or any maintenance. Ensure proper wiring and grounding according to local electrical codes. Use appropriate external circuit protection, such as fuses or circuit breakers, rated for the connected load.


Does the Siemens 7KT1668 support multiple tariffs or time-of-use billing?

The base model of the Siemens 7KT1668 SENTRON PAC1100 is designed for basic energy measurement and typically does not support multi-tariff functionalities directly. For advanced tariff management, integration with a higher-level system via Modbus RTU would be necessary to process and apply different rates based on time or other factors.


What is the expected lifespan and long-term value of this energy meter?

Built with Siemens' renowned industrial quality, the 7KT1668 is designed for a long operational lifespan in demanding environments. Its value is enhanced by its accurate measurements, compact design, and the scalability offered by its communication capabilities, allowing it to remain relevant in evolving energy management strategies.

Menu