OULU EV510A-1850G/2000P-T4 High Performance VFD Drive 340A 200kW

stars
  • Availability:In Stock
  • Brand: OULU
  • Model:EV510A-1850G/2000P-T4
  • HS: 8504409999
Availability:In Stock
$2700.00
zhongpingtech

The OULU EV510A-1850G/2000P-T4 High Performance VFD Drive, a robust 340A, 200kW variable frequency drive, delivers exceptional motor control for demanding industrial applications. Its advanced design ensures superior energy efficiency, precise speed regulation, and enhanced system reliability, making it a premier choice for sectors requiring high-performance motor operation. Key advantages include its compact footprint, robust thermal management, and sophisticated control algorithms that optimize performance across a wide load spectrum.


Product Specifications


| Parameter                   | Value                                   |

| :-------------------------- | :-------------------------------------- |

| Model Number                | EV510A-1850G/2000P-T4                   |

| Rated Current (Amps)        | 340A                                    |

| Rated Power (kW)            | 200kW                                   |

| Input Voltage (V)           | 400V Class (typical, specific range varies) |

| Output Voltage (V)          | 0-400V (adjustable)                     |

| Control Method              | Vector Control, V/f Control             |

| Protection Rating           | IP20 (standard, higher available)       |

| Dimensions (H x W x D, mm)  | Specific dimensions to be confirmed     |

| Operating Temperature (°C)  | -10°C to +50°C (derating may apply)      |

| Braking Unit                | Integrated/Optional (depending on variant) |


Core Features & Market Positioning


The OULU EV510A-1850G/2000P-T4 distinguishes itself through its advanced sensorless vector control, providing precise torque and speed responsiveness even under dynamic load conditions. This drive is engineered for superior thermal dissipation, utilizing an optimized heatsink design and intelligent fan control to ensure reliable operation in harsh environments and extended duty cycles. Its market positioning centers on delivering high-performance, energy-efficient motor control solutions for critical industrial processes where uptime and precision are paramount. The drive's robust build quality and comprehensive protection features also contribute to its reputation for longevity and reduced maintenance requirements.


Key Application Scenarios


This high-performance VFD is ideally suited for a broad array of industrial applications demanding precise motor control and high power output. Its capabilities are particularly valuable in applications such as heavy-duty pump and fan systems in HVAC and water treatment, complex conveyor systems in logistics and manufacturing, and high-torque motor drives for extruders and mixers in the plastics and chemical industries. The EV510A-1850G/2000P-T4 excels in scenarios requiring rapid acceleration/deceleration, stable low-speed operation, and efficient energy savings, directly impacting operational efficiency and cost reduction.


Practical System Integration Guidance


Integrating the OULU EV510A-1850G/2000P-T4 into existing industrial systems is streamlined through its flexible configuration options and robust communication protocols. Proper installation involves ensuring adequate ventilation, adhering to wiring best practices for high-power VFDs, and correctly grounding all components to prevent electrical interference. The drive supports various digital and analog I/O for seamless integration with PLCs and other control systems, and its parameter programming interface allows for detailed customization of motor performance characteristics, ramp times, and protective functions. Attention to input power quality and output load matching is crucial for optimal performance and longevity.


Operation and Risk Mitigation


Safe and effective operation of the OULU EV510A-1850G/2000P-T4 mandates adherence to electrical safety standards and manufacturer guidelines. Before initial startup, a thorough review of the user manual, particularly sections on wiring, parameter setup, and emergency stop procedures, is essential. Critical fault codes, such as overcurrent (OC), overvoltage (OV), undervoltage (UV), and overheating (OH), should be understood to enable swift troubleshooting. Implementing appropriate braking resistors for high-inertia loads or frequent stops can prevent overvoltage during deceleration, thereby mitigating risks of component damage and ensuring operational continuity.


Scalability & Long-Term Value


The OULU EV510A-1850G/2000P-T4 offers significant long-term value through its inherent scalability and compatibility with modern industrial automation trends. Its modular design and support for standard industrial communication protocols (e.g., Modbus RTU, optional fieldbus modules) facilitate seamless integration into Industrial Internet of Things (IIoT) platforms and supervisory control and data acquisition (SCADA) systems. This enables advanced monitoring, diagnostics, and predictive maintenance capabilities. Furthermore, the drive's robust construction and energy-saving features contribute to reduced operational expenditure, extending the return on investment and ensuring sustained operational efficiency over the product's lifecycle.


*


Frequently Asked Questions


What is the primary function of the OULU EV510A-1850G/2000P-T4 VFD?

The OULU EV510A-1850G/2000P-T4 VFD's main role is to control the speed and torque of AC electric motors with high precision. It achieves this by varying the frequency and voltage supplied to the motor. This control leads to significant energy savings and improved process performance in industrial settings.


This variable frequency drive is essential for optimizing motor performance in applications requiring precise speed adjustment. Its advanced vector control technology ensures accurate torque delivery, crucial for dynamic loads and demanding industrial processes. The drive's ability to adapt motor output to the actual demand minimizes energy waste.


Ultimately, this VFD enhances operational efficiency, reduces mechanical stress on equipment, and lowers overall energy consumption. Its robust design ensures reliability and longevity, providing a cost-effective solution for sophisticated motor control needs.


What are the key technical specifications of this high-performance VFD?

This VFD boasts a 340A current rating and supports a 200kW motor power output. It operates on a 400V class input voltage and provides an adjustable output voltage range from 0 to 400V. The drive supports both sensorless vector control and V/f control methods for versatile application compatibility.


Its standard protection rating is IP20, suitable for controlled environments, with options for higher ingress protection. The operating temperature range is typically -10°C to +50°C, though derating may apply at higher temperatures. Integrated or optional braking units are available depending on specific model variants.


The OULU EV510A-1850G/2000P-T4 is designed for robust performance, featuring advanced thermal management and precise motor control algorithms. These specifications make it suitable for demanding industrial applications where reliability and efficiency are paramount.


In which industrial sectors is the OULU EV510A-1850G/2000P-T4 VFD most commonly applied?

This VFD finds extensive application in heavy industries such as manufacturing, water treatment, and logistics. Its high power output and precise control are ideal for driving large pumps, fans, compressors, and complex conveyor systems. Applications requiring precise speed regulation and high starting torque, like extruders and mixers, also benefit greatly.


Sectors like HVAC, mining, and chemical processing commonly utilize this drive for applications demanding consistent performance under varying load conditions. Its ability to optimize energy consumption makes it a valuable asset in industries focused on operational efficiency and cost reduction.


The robustness and advanced control features of the EV510A-1850G/2000P-T4 ensure reliable operation in harsh environments, making it a preferred choice for critical industrial processes where downtime is not an option.


How does the OULU EV510A-1850G/2000P-T4 ensure energy efficiency?

The drive achieves energy efficiency by precisely matching motor speed to the required load, rather than running motors at full speed constantly. Its advanced control algorithms minimize energy losses during acceleration, deceleration, and steady-state operation. This results in significant power savings compared to traditional motor control methods.


By utilizing sophisticated techniques like sensorless vector control, the drive optimizes motor torque output, reducing unnecessary power draw. This precise control prevents over-application of power, directly translating into lower electricity bills and a reduced carbon footprint for the facility.


Furthermore, features such as intelligent fan control and effective thermal management ensure the drive itself operates efficiently, dissipating heat effectively without consuming excessive auxiliary power. This holistic approach to efficiency makes it a sustainable choice for modern industrial operations.


What are the advantages of using sensorless vector control in this VFD?

Sensorless vector control provides highly accurate motor speed and torque regulation without the need for external motor encoders. This simplifies installation and reduces costs by eliminating the encoder and its associated wiring. It delivers performance comparable to closed-loop systems for many demanding applications.


This control method ensures excellent dynamic response, allowing the motor to react quickly to changes in load. It also enables precise speed holding capabilities, even at low speeds or under fluctuating torque demands, which is critical for many industrial processes.


The OULU EV510A-1850G/2000P-T4's implementation of sensorless vector control enhances overall system reliability by reducing potential points of failure, making it a robust and cost-effective solution.


Can this VFD be integrated with existing automation systems like PLCs?

Yes, the OULU EV510A-1850G/2000P-T4 is designed for seamless integration with PLC systems and other industrial automation platforms. It typically supports standard industrial communication protocols such as Modbus RTU. Optional fieldbus modules for popular networks like Profibus, Profinet, or Ethernet/IP can also be integrated.


The drive features configurable digital and analog inputs/outputs (I/O). These I/O points allow for straightforward connection to PLCs for receiving control commands, sending status feedback, and triggering alarms. This ensures flexible and robust system architecture design.


Proper integration involves configuring the communication parameters on both the VFD and the PLC, as well as mapping the relevant data registers for efficient data exchange. This ensures reliable operation and centralized control of the motor within the overall automation scheme.


What type of motor is compatible with the OULU EV510A-1850G/2000P-T4?

This VFD is designed to control standard three-phase AC induction motors. It is compatible with both standard efficiency and high-efficiency (IE3, IE4) motors within its rated power and current range. The drive's flexible parameter settings allow for optimization of performance for a wide variety of motor types and characteristics.


While primarily designed for induction motors, the advanced control capabilities might also support other motor types with appropriate parameter configuration. Always consult the product manual to confirm compatibility with specific motor technologies or specialized motor designs.


Ensuring the motor's nameplate data (voltage, current, frequency, power rating) aligns with the VFD's capabilities and the application's load requirements is crucial for optimal performance and longevity of both the motor and the drive.


What are common troubleshooting steps for issues with this VFD?

When encountering issues, the first step is to check the VFD's display for any active fault codes. Referencing the user manual for the specific code will provide insight into the nature of the problem, such as overcurrent, overvoltage, or overheating. Basic checks include verifying input power supply stability and ensuring all wiring connections are secure and correctly terminated.


Secondly, examine environmental factors. Ensure the drive is operating within its specified temperature and humidity range and that ventilation is unobstructed. Dust accumulation on heatsinks or cooling fans can impede performance and lead to faults. Check that the motor is properly connected and has no internal faults or short circuits.


Finally, review the drive's programmed parameters. Incorrect settings for motor data, acceleration/deceleration ramps, or protection thresholds can cause unexpected behavior or faults. Resetting parameters to factory defaults (after documenting current settings) can sometimes resolve configuration-related issues, but always proceed with caution.


How is the OULU EV510A-1850G/2000P-T4 installed and commissioned?

Installation requires mounting the VFD in a well-ventilated area, adhering to minimum clearance distances specified in the manual to ensure proper heat dissipation. Ensure the power supply is correctly connected, with appropriate circuit protection (fuses or breakers). Motor wiring must be robust and properly shielded to minimize electrical noise, and grounding must be meticulously applied according to standards.


Commissioning begins with initial parameter setup, which includes inputting motor nameplate data (voltage, current, frequency, RPM, power factor) to allow the VFD to tune its control algorithms. Basic parameter configuration such as acceleration/deceleration times, speed references, and I/O assignments should be performed. Safety functions, including emergency stop connections, must be verified.


After initial setup, perform a low-speed test run to check motor rotation direction and basic operation. Gradually increase speed while monitoring motor performance, current draw, and any fault indications. Fine-tuning of parameters like current limits and torque boost may be necessary to achieve optimal performance for the specific application.


What safety precautions should be taken when operating this VFD?

Always disconnect power and wait for the internal DC bus capacitors to discharge fully before performing any electrical work or maintenance on the VFD. Ensure that all personnel working with or around the VFD are properly trained in electrical safety procedures and lockout/tagout protocols. Never operate the drive without a proper motor and load connected.


The VFD enclosure should be securely mounted and grounded. Avoid exposing the drive to excessive moisture, dust, or extreme temperatures outside of its specified operating range. Ensure that all protective covers are in place during operation to prevent accidental contact with live electrical components.


Implement emergency stop functionality that reliably disconnects power to the motor and drive in critical situations. Regularly inspect wiring and connections for signs of wear or damage. Understand the drive's fault codes and their implications to respond appropriately to any anomalies during operation.