INVT GD270-022-4 Special VFD for Water Pump & Fan Drive

stars
  • Availability:In Stock
  • Brand:INVT
  • Model:GD270-022-4
  • HS: 8504409999
Availability:In Stock
$465.80
zhongpingtech

The INVT GD270-022-4, a specialized Variable Frequency Drive (VFD), stands out as a robust solution engineered specifically for water pump and fan applications. This VFD boasts a power rating of 22 kW (30 HP) and operates on a three-phase 380V/400V/415V input, delivering exceptional performance and energy efficiency. Its core advantages lie in its advanced control algorithms, designed to optimize motor speed for varying load conditions, thereby significantly reducing energy consumption and extending equipment lifespan. Key technical parameters include an output frequency range of 0-300 Hz, overload capacity of 150% for 60 seconds, and integrated protection features safeguarding against common electrical faults. The GD270 series excels in delivering precise speed control and enhanced system reliability for critical fluid and air movement operations.


Product Specifications


| Feature                 | Specification                               |

| :---------------------- | :------------------------------------------ |

| Model                   | GD270-022-4                                 |

| Rated Power             | 22 kW (30 HP)                               |

| Input Voltage           | 3-Phase 380V/400V/415V                      |

| Output Frequency        | 0 - 300 Hz                                  |

| Overload Capacity       | 150% of rated current for 60 seconds        |

| Control Method          | V/f Control, Vector Control (Sensorless)    |

| Protection Features     | Over-voltage, Under-voltage, Over-current, Overload, Overheating, Short-circuit |

| Communication Interface | RS485 (Modbus RTU)                          |

| Ambient Temperature     | -10°C to +40°C                              |

| Protection Rating       | IP20                                        |


Core Features & Market Positioning


The INVT GD270-022-4 distinguishes itself in the competitive VFD market through its specialized design for pump and fan duties, offering superior energy savings and operational efficiency compared to general-purpose drives. Its advanced sensorless vector control provides precise torque and speed regulation, crucial for maintaining system performance under dynamic load changes. The integrated PID controller allows for closed-loop system management without external controllers, simplifying system architecture and reducing installation costs. Market positioning is reinforced by its robust build quality, comprehensive protection functions, and reliable performance in demanding industrial environments, making it a cost-effective and dependable choice for optimizing water and air handling systems.


Key Application Scenarios


This specialized VFD is ideally suited for a wide array of water pump and fan applications. In municipal water supply and wastewater treatment plants, the GD270-022-4 efficiently manages centrifugal pumps, ensuring consistent pressure and flow rates while minimizing energy expenditure. For HVAC systems in commercial and industrial buildings, it precisely controls fan speeds to optimize air circulation and maintain desired temperature and humidity levels, leading to significant energy savings. Furthermore, it finds application in irrigation systems, industrial process cooling, and building ventilation, wherever variable speed control of pumps and fans is required to match operational demands and reduce power consumption.


Practical System Integration Guidance


Integrating the INVT GD270-022-4 into existing systems is streamlined due to its user-friendly interface and comprehensive connectivity options. For wiring, ensure the input power terminals (L1, L2, L3) are connected to the main power supply and the output terminals (T1, T2, T3) are connected to the motor. Grounding is critical for safety and electromagnetic interference reduction; connect the ground terminal to a verified earth ground. For motor connections, use shielded cables to minimize noise, especially in environments with high electrical interference. Basic programming involves setting motor parameters such as rated voltage, frequency, current, and pole number via the keypad or through the RS485 communication port using Modbus RTU protocol for remote control and monitoring. The internal PID controller can be configured by setting the setpoint, feedback source, and proportional, integral, and derivative gains to achieve desired system response.


Operation and Risk Mitigation


Safe operation of the INVT GD270-022-4 mandates adherence to installation and operation guidelines. Always ensure the VFD is properly grounded and that all electrical connections are secure before energizing. Avoid operating the VFD in environments exceeding its specified temperature or humidity range, as this can lead to component failure or reduced performance. Common troubleshooting involves checking for fault codes displayed on the HMI. For instance, an "Overcurrent" fault (often code F02) typically indicates an issue with motor load, wiring, or an acceleration time set too short, requiring adjustment of acceleration ramp times or inspection of the motor and driven load. "Over-voltage" faults (e.g., F03) might suggest excessive line voltage or insufficient braking, necessitating checks on the power supply or consideration of a braking resistor. Regular visual inspections and adherence to maintenance schedules, as outlined in the user manual, are vital for long-term reliability and risk mitigation.


Scalability & Long-Term Value


The INVT GD270-022-4 offers considerable scalability and long-term value within industrial automation frameworks. Its compatibility with standard communication protocols like Modbus RTU facilitates seamless integration into SCADA systems and Programmable Logic Controllers (PLCs), enabling centralized monitoring and control. This interoperability supports the development of smart industrial environments and the Industrial Internet of Things (IIoT), allowing for data analytics, predictive maintenance, and remote diagnostics. Future-proofing is enhanced by INVT's commitment to firmware updates, which can introduce new features and performance optimizations. Furthermore, the robust design and energy-saving capabilities ensure a rapid return on investment through reduced operational costs and extended equipment life, making it a strategically sound choice for long-term operational efficiency and system expansion.


Frequently Asked Questions (FAQs)


What is the maximum input voltage tolerance for the INVT GD270-022-4?

The INVT GD270-022-4 is designed for a nominal input voltage of 3-Phase 380V/400V/415V. It typically accommodates a voltage variation within ±10% of the rated input voltage. Exceeding these tolerances can lead to over-voltage or under-voltage faults, potentially damaging the drive.


How does the GD270-022-4 achieve energy savings in fan applications?

It achieves energy savings by precisely matching motor speed to the actual airflow demand. By reducing fan speed, the VFD significantly lowers power consumption, as fan power is proportional to the cube of speed. This variable speed operation avoids energy wastage associated with constant speed fans.


Can the INVT GD270-022-4 be used with single-phase motors?

No, the INVT GD270-022-4 is specifically designed for three-phase motors. Connecting a single-phase motor to this drive will result in motor damage and drive malfunction. Ensure your motor is three-phase for compatibility.


What are the recommended operating temperature limits for the GD270-022-4?

The VFD is rated for operation in ambient temperatures ranging from -10°C to +40°C. Operating outside this range can affect performance and lifespan. Ensure adequate ventilation and consider derating if operating at the higher end of the temperature spectrum.


How do I connect the INVT GD270-022-4 for remote control?

Remote control is typically achieved via the RS485 communication port using the Modbus RTU protocol. Connect your master controller (e.g., PLC) to the VFD's A and B terminals. Configure communication parameters on both the VFD and the master controller.


What does an "Overload" fault on the GD270-022-4 signify?

An overload fault (often indicated by F01) means the VFD has detected that the motor is drawing more current than it can safely handle for a sustained period. This could be due to a motor operating under excessive load, insufficient cooling, or acceleration times set too short.


How can I reset a fault on the INVT GD270-022-4?

Most faults can be reset by pressing the "STOP" or "RESET" button on the keypad once the underlying fault condition has been resolved. For persistent issues, a power cycle (turning the drive off and then back on) may be necessary. Always address the root cause before resetting.


Is the INVT GD270-022-4 suitable for submersible pump applications?

While designed for water pumps, the GD270-022-4 itself has an IP20 rating, meaning it requires protection from moisture and dust. It must be installed in a suitable enclosure when used in environments exposed to water or high humidity, like near submersible pumps.


What is the typical lifespan of the INVT GD270-022-4?

With proper installation, operation within specified limits, and regular maintenance, the GD270-022-4 can have a lifespan exceeding 10 years. Key components like cooling fans and capacitors may require periodic replacement as part of preventative maintenance.


Can the GD270-022-4 support multiple pumps or fans from a single drive?

Generally, a single VFD is designed to control one motor at a time. While it's technically possible to use external contactors to switch between multiple loads, this is not recommended for direct VFD control as it can lead to damage. Dedicated VFDs for each motor are standard practice.