INVT GD270-185-4 Special Inverter for Pump & Fan VFD

stars
  • Availability:In Stock
  • Brand:INVT
  • Model:GD270-185-4
  • HS: 8504409999
Availability:In Stock
$2673.80
zhongpingtech

The INVT GD270-185-4 is a specialized Variable Frequency Drive (VFD) engineered for optimal performance in pump and fan applications. This inverter boasts exceptional energy efficiency, precise control capabilities, and robust protection features, making it a leading choice for HVAC, water supply, and industrial ventilation systems. Its core advantages lie in its advanced control algorithms, integrated PID functions, and a compact, user-friendly design. Key technical parameters include a power rating of 185kW (250HP), a 400V voltage class, and an IP20 enclosure rating, ensuring reliable operation in demanding industrial environments.


Product Specifications


| Feature                 | Specification                               |

| :---------------------- | :------------------------------------------ |

| Model                   | GD270-185-4                                 |

| Rated Power (kW)        | 185                                         |

| Rated Power (HP)        | 250                                         |

| Input Voltage (3-Phase) | 380V/400V/415V (-15% to +10%)              |

| Output Voltage          | 0-Input Voltage                             |

| Frequency Range         | 0-400 Hz                                    |

| Control Method          | V/f Control, Sensorless Vector Control      |

| Protection Class        | IP20                                        |

| Mounting                | Wall-mounted                                |

| Dimensions (H x W x D)  | 890mm x 550mm x 330mm (approximate)         |

| Weight                  | 55 kg (approximate)                         |


Core Features & Market Positioning


The INVT GD270-185-4 distinguishes itself through its dedicated pump and fan control modes, which optimize energy consumption and system longevity. It incorporates advanced sensorless vector control for precise speed regulation, even under varying load conditions, a critical factor in maintaining stable system pressures and flows. Its market positioning is defined by its balance of sophisticated features, reliability, and cost-effectiveness, targeting industrial users who require high-performance VFD solutions without excessive complexity. The integrated bypass function further enhances operational flexibility and reduces downtime during maintenance or unexpected VFD issues.


Key Application Scenarios


This specialized VFD finds extensive application in building automation, particularly within HVAC systems for controlling air handling units, chillers, and exhaust fans, ensuring optimal indoor climate control and energy savings. In water management, the GD270-185-4 is ideal for constant pressure water supply systems, sewage pump stations, and irrigation systems, where precise flow and pressure regulation are paramount. Its robust design also makes it suitable for various industrial ventilation needs, such as in manufacturing plants, mining operations, and tunnel ventilation, where efficient air movement is crucial for safety and productivity.


Practical System Integration Guidance


Integrating the INVT GD270-185-4 into existing systems is streamlined by its flexible wiring options and intuitive parameter settings. For pump and fan applications, selecting the appropriate control mode (e.g., V/f for simple systems, or sensorless vector for high-precision needs) is essential for optimal performance. Wiring should strictly follow the manual's guidelines, ensuring proper grounding and connection of motor power leads, control signals, and any optional communication modules. Commissioning involves a careful parameter setup, including motor data entry, setting acceleration/deceleration times, and configuring PID loops for closed-loop pressure or flow control, ensuring the VFD operates in harmony with the driven equipment.


Operation and Risk Mitigation


Safe operation of the INVT GD270-185-4 is paramount and relies on adherence to installation and operating instructions. Users should be aware of potential hazards associated with high voltage and ensure proper lockout/tagout procedures are followed during maintenance. Common troubleshooting scenarios often involve motor overload or under-voltage faults, which can typically be resolved by checking motor parameters, load conditions, and input power quality. Critical error codes, such as "Overcurrent" (OC) or "Overvoltage" (OV), indicate specific issues that require immediate attention and diagnosis as outlined in the product's technical manual to prevent damage to the VFD or connected equipment.


Scalability & Long-Term Value


The INVT GD270-185-4 offers significant long-term value through its compatibility with various industrial communication protocols, enabling seamless integration into SCADA and IIoT platforms. This facilitates remote monitoring, diagnostics, and predictive maintenance, enhancing operational efficiency and reducing unexpected downtime. While direct hardware upgrade paths within the GD270 series might be limited, its robust design and comprehensive feature set ensure it remains a relevant solution for many years. Furthermore, INVT's commitment to continuous firmware development allows for feature enhancements and performance improvements over the product's lifecycle.


FAQs


What is the primary advantage of the INVT GD270-185-4 for fan applications?

This VFD offers optimized airflow control and significant energy savings by precisely matching fan speed to demand, reducing wasted energy.


It features specialized control algorithms designed to prevent motor stress and extend the lifespan of fan components.


The GD270-185-4 provides quiet operation and enhanced system stability, crucial for sensitive environments like cleanrooms.


How does the GD270-185-4 handle fluctuating water pressure in pumping systems?

The inverter employs advanced PID control to maintain a constant output pressure, automatically adjusting pump speed as demand changes.


Its sensorless vector control ensures smooth and responsive adjustments, preventing water hammer and system shock.


This capability directly translates to improved water delivery consistency and reduced wear on pump seals and motor bearings.


What are the key input power requirements for the INVT GD270-185-4?

The unit requires a 3-phase AC input power supply within the 380V to 415V range, with a tolerance of -15% to +10%.


Proper grounding and connection to a stable power source are critical for preventing faults and ensuring reliable operation.


Users must verify that their power grid's voltage and frequency characteristics align with the VFD's specifications to avoid damage.


Can the INVT GD270-185-4 be controlled remotely?

Yes, this VFD supports various communication protocols for integration into supervisory control systems.


Remote monitoring of operational status, speed, and fault diagnostics is readily achievable with appropriate modules.


This remote control capability enhances operational flexibility and enables centralized management of multiple pumping or fan systems.


What safety features are integrated into the GD270-185-4?

The VFD incorporates comprehensive motor and drive protection functions, including overcurrent, overvoltage, and undervoltage protection.


It also provides thermal protection for the motor and the drive itself, preventing damage due to overheating.


Emergency stop functions and safe torque-off capabilities are available, ensuring rapid shutdown in critical situations.


How do I set up the PID control for a constant pressure application?

Access the PID parameter menu and configure the setpoint for the desired pressure and the feedback input source (e.g., an analog sensor).


Adjust the PID proportional, integral, and derivative gains to achieve stable and responsive pressure regulation without oscillations.


Test the system under various flow rates to fine-tune the PID parameters for optimal performance across the entire operating range.


What is the typical power consumption of the GD270-185-4 under partial load?

Under partial load, the energy savings are substantial, as the VFD significantly reduces power consumption compared to direct-on-line operation.


The exact consumption depends on the load percentage, motor efficiency, and system dynamics, but savings can reach 30-60%.


This efficiency gain directly contributes to reduced operational costs and a lower carbon footprint for the facility.


What are common troubleshooting steps for an "Overcurrent" fault?

First, check the motor's nameplate data and ensure it's correctly entered into the VFD parameters; incorrect values can trigger false faults.


Inspect the driven equipment for mechanical issues such as bearing problems or blockages that could be causing excessive motor load.


Verify the motor power cables for damage or loose connections, and ensure the motor is properly sized for the application.


Is the INVT GD270-185-4 suitable for variable torque applications?

Absolutely, the GD270-185-4 is specifically designed for variable torque applications like pumps and fans, where torque requirements decrease with speed.


Its advanced control algorithms ensure efficient operation, delivering significant energy savings in these scenarios.


The VFD's ability to precisely control speed in variable torque loads prevents oversizing and extends the life of the motor and driven equipment.


What kind of maintenance is required for this inverter?

Regular visual inspections for dust accumulation and loose connections are recommended, along with cleaning the ventilation pathways.


Periodically check the input and output voltage and current readings to ensure they remain within specified parameters.


Firmware updates, if available, can enhance performance and add new features, so staying current with manufacturer recommendations is advised.

Menu