DANFOSS FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX 15kW 480V Three Phase Automation Inverter

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$2507.60
zhongpingtech

The DANFOSS FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX 15kW 480V Three Phase Automation Inverter is a high-performance variable frequency drive engineered for demanding industrial automation applications. Its robust design and advanced control capabilities deliver exceptional energy efficiency, precise motor control, and enhanced system reliability. Key advantages include its advanced thermal management, flexible programming options, and integrated safety features, positioning it as a superior choice for critical process control. This inverter boasts a 15kW power rating, operates on a 480V three-phase power supply, and offers a comprehensive set of features for seamless integration into complex automation systems.


Product Specifications


| Feature                 | Specification                                         |

| :---------------------- | :---------------------------------------------------- |

| Model Number            | FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX                |

| Power Rating            | 15 kW                                                 |

| Input Voltage           | 480V, Three Phase                                     |

| Output Frequency        | 0-599 Hz                                              |

| Control Method          | VVCplus, Vector Control, Scalar Control               |

| Protection Class        | IP21 (Standard), IP54/IP66 (Optional)                 |

| Ambient Temperature     | -20°C to +50°C (with derating above 40°C)             |

| Harmonic Distortion     | Meets IEEE 519 standard with built-in filters         |

| Braking Options         | Integrated braking chopper, external braking resistor |

| Communication Protocols | Modbus RTU, Profibus DP, DeviceNet, EtherNet/IP       |

| Certifications          | UL, CE, CSA                                           |


Core Features & Market Positioning


The DANFOSS FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX stands out in the industrial automation market due to its sophisticated VVCplus control, which provides unparalleled accuracy and responsiveness for motor speed and torque regulation, even under fluctuating loads. This advanced control strategy significantly reduces energy consumption and wear on mechanical components, translating to lower operational costs and extended equipment lifespan. Its modular design enhances flexibility, allowing for easy customization with optional modules for enhanced communication, I/O expansion, and safety functions, making it adaptable to a wide range of system requirements. The inverter's robust construction and advanced thermal management ensure reliable operation in harsh industrial environments, further solidifying its market position as a premium, durable solution for critical applications.


Key Application Scenarios


This automation inverter is exceptionally well-suited for a diverse array of industrial applications demanding precise motor control and high efficiency. It is a prime choice for variable speed drives in pump and fan systems, where energy savings are paramount and precise flow or pressure control is required. In material handling, the FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX excels in conveyor systems, mixers, and elevators, providing smooth acceleration and deceleration for delicate product handling and efficient throughput. Furthermore, its robust performance makes it ideal for applications in the HVAC sector, manufacturing processes, and water treatment plants, where consistent and reliable operation under varying load conditions is essential.


Practical System Integration Guidance


Integrating the DANFOSS FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX into your automation setup is streamlined by its user-friendly interface and comprehensive connectivity options. For optimal performance and safety, ensure proper grounding and use shielded motor cables to minimize electromagnetic interference. The inverter supports various communication protocols, allowing for seamless integration with PLCs and SCADA systems; for instance, establishing Modbus RTU communication involves connecting to terminals R+ and T+ for the A line and R- and T- for the B line, and configuring the relevant parameters for baud rate, parity, and slave address. Commissioning typically involves parameter setting via the control panel or software, where motor data must be accurately entered for autotuning to achieve optimal drive performance. Always refer to the specific installation manual for detailed wiring diagrams and parameter configuration relevant to your application.


Operation and Risk Mitigation


Operating the DANFOSS FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX requires adherence to safety guidelines to prevent damage and ensure personnel safety. Always disconnect power before performing any maintenance or wiring. Common troubleshooting involves checking for overload faults (e.g., Fault 1, 2, or 3), which can often be resolved by verifying the motor load and ensuring the drive is correctly sized for the application; motor parameters must be accurately set. Undervoltage faults may indicate issues with the incoming power supply or a failure in the drive's DC link; overcurrent faults suggest a short circuit or excessive motor acceleration. Regular inspection of ventilation and heatsink cleanliness is crucial for preventing thermal shutdown faults.


Scalability & Long-Term Value


The DANFOSS FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX offers significant scalability and long-term value through its compatibility with Danfoss's broader automation ecosystem and support for Industrial Internet of Things (IIoT) integration. Its modular design allows for easy upgrades and expansion of I/O capabilities or communication options as system demands evolve, ensuring the drive remains relevant and effective for years to come. Integration with cloud-based monitoring platforms and predictive maintenance solutions enables remote diagnostics, performance optimization, and proactive issue resolution, maximizing uptime and reducing total cost of ownership. This forward-looking design ensures your automation investment remains efficient and adaptable in the face of technological advancements.


FAQs


What are the primary benefits of using the DANFOSS FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX?

This inverter offers superior energy efficiency through advanced control algorithms. It provides precise motor control for enhanced process accuracy and reduced wear. Its robust design ensures high reliability in demanding industrial environments.


How does the VVCplus control method enhance performance?

VVCplus (Variable Voltage, Variable Frequency Control) optimizes motor voltage and frequency dynamically. This results in excellent torque control, even at low speeds. It significantly reduces harmonic distortion and energy consumption.


What types of applications are best suited for this inverter?

It excels in pump and fan applications for HVAC and water systems. It is also ideal for material handling, conveyors, and mixers. Manufacturing processes requiring precise speed and torque control benefit greatly.


What is the typical power range for this inverter series?

The specific model FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX is rated for 15kW. The FC-301 series offers a broad range of power options to suit various industrial motor sizes. Consult Danfoss documentation for the full available spectrum.


How do I connect the DANFOSS FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX to a PLC using Modbus RTU?

Connect the inverter's A and B terminals (R+ and R-, T+ and T-) to the PLC's Modbus communication ports. Configure both the inverter and PLC with matching Modbus addresses, baud rate, and parity settings. Ensure correct termination for reliable communication over the bus.


What are the key considerations for system integration and installation?

Proper grounding and shielded motor cables are essential for minimizing electrical noise. Ensure adequate ventilation around the inverter to prevent overheating. Accurately input motor parameters for auto-tuning to optimize performance.


What are common fault codes and their meanings for this inverter?

Fault 1, 2, or 3 typically indicates motor overload; check load and motor parameters. Fault 4 or 5 may signify an overcurrent condition; inspect for shorts or rapid acceleration. Fault 8 or 9 often relates to undervoltage, check power supply stability.


How can I ensure long-term value and scalability with this product?

Its modular design allows for future expansion of I/O and communication options. It integrates seamlessly with other Danfoss automation components. It supports IIoT connectivity for enhanced monitoring and diagnostics.


What safety features are integrated into the DANFOSS FC-301P15KT4E20H2XGCXXXSXXXXAXBXCXXXXDX?

It often includes safety functions like Safe Torque Off (STO) for emergency stops. Integrated braking choppers enhance deceleration control. Adherence to proper installation and maintenance procedures is critical for operational safety.


What is the warranty period for this automation inverter?

Warranty periods can vary based on region and specific sales agreements. It is recommended to consult the product documentation or your Danfoss sales representative for precise warranty details. Extended warranty options may also be available.

Menu