Delta AS64AN02T-A Module de sortie transistor CC haute densité 64 points

stars
  • Disponibilité:En stock
  • Marque: DELTA
  • Modèle : AS64AN02T-A
  • HS : 8538900000
Disponibilité:En stock
$158.03
zhongpingtech

The Delta AS64AN02T-A is a high-density 64-point DC transistor output module designed to expand the capabilities of Delta's AS Series PLCs. This module offers robust performance and significant I/O expansion, making it suitable for a wide range of automated equipment. Key advantages include its high point count, NPN transistor output type, and seamless integration within the Delta AS Series ecosystem. Technical parameters such as a 5-30 VDC operating voltage and 0.1 A per output current rating highlight its application suitability for controlling various loads.


Spécifications du produit


| Fonctionnalité                 | Spécification                                  |

| :---------------------- | :--------------------------------------------- |

| Série compatible       | Série AS                                      |

| Classement          | Module de sortie numérique                          |

| Points d'E/S              | 64 sorties                                     |

| Type de sortie             | Sortie transistor NPN                          |

| Tension nominale          | 5 à 30 VCC                                   |

| Courant nominal (par sortie) | 0.1 A                                          |

| Note actuelle (par COM)  | 3.2 A                                          |

| Style de terminaison       | Connecteur MIL (2x IDC-40)                      |

| Type de montage           | Montage sur châssis, rail DIN                        |

| Température de fonctionnement   | -20 à 60 °C                                   |

| Protection contre la pénétration      | IP20                                           |

| Consommation électrique       | 1,44 W (interne)                              |


Caractéristiques principales et positionnement sur le marché


The Delta AS64AN02T-A stands out in the industrial automation market due to its high output density, offering 64 individual transistor outputs within a compact module. This allows for significant space savings on control panels compared to using multiple lower-density modules. Its NPN transistor output configuration is a common requirement in many industrial applications, simplifying integration with various actuators, solenoids, and indicator lights. As part of the Delta AS Series, it benefits from the platform's high-speed execution capabilities and advanced CPU performance, positioning it as a reliable and efficient choice for demanding automation tasks. The module's design emphasizes ease of installation and maintenance, aligning with Delta's commitment to user-friendly industrial solutions.


Scénarios d'application clés


Le Delta AS64AN02T-A est parfaitement adapté aux applications nécessitant un contrôle de sortie étendu. Cela inclut des machines d'emballage complexes, des systèmes d'étiquetage à grande vitesse, des équipements de fabrication électronique complexes et des machines textiles où un contrôle précis de nombreux résultats est essentiel. Sa capacité à gérer 64 points de sortie distincts le rend inestimable dans les chaînes d'assemblage, les systèmes de manutention et tout processus automatisé exigeant l'activation séquentielle ou parallèle de plusieurs dispositifs tels que des moteurs, des vannes, des relais ou des voyants lumineux.


Guide pratique d’intégration du système


Integrating the Delta AS64AN02T-A into an existing or new AS Series PLC system is straightforward, leveraging the platform's modular design. The module connects via IDC-40 MIL connectors, typically requiring compatible wiring modules for external connections. It is designed for DIN rail mounting, facilitating quick installation within control cabinets. The AS Series software, such as ISPSoft, provides tools for hardware configuration and programming, enabling users to easily assign I/O addresses and develop control logic for the 64 output points. Referencing the AS Series Hardware Manual is recommended for detailed wiring diagrams and connection procedures to ensure proper setup and prevent damage.


Opération et atténuation des risques


Le bon fonctionnement du Delta AS64AN02T-A implique de s'assurer qu'il est installé dans sa plage de température de fonctionnement et ses conditions environnementales spécifiées (IP20). Chaque sortie est évaluée à 0,1 A et le courant COM total est de 3,2 A ; le dépassement de ces limites peut entraîner une défaillance du module ou des dommages aux appareils connectés. La protection contre les surintensités doit être mise en œuvre au niveau de l'application ou via des dispositifs de protection externes. Une inspection régulière, comme indiqué dans le manuel du matériel de la série Delta AS, à l'aide d'outils de base tels que des tournevis et des chiffons propres, est conseillée pour l'entretien périodique afin d'identifier tout problème potentiel et de garantir une fiabilité à long terme.


Évolutivité et valeur à long terme


The Delta AS64AN02T-A enhances the scalability of the AS Series PLC system. The AS Series itself supports up to 32 extension modules and a total of 1,024 I/O points, allowing for significant system expansion. This 64-point output module contributes to this high I/O capacity, enabling users to build more complex and sophisticated automation solutions without needing to replace their existing PLC hardware. Compatibility with Delta's broader ecosystem, including motion control and various communication modules, ensures that systems can be upgraded and integrated with emerging IIoT and digital manufacturing technologies, providing long-term value and adaptability.


Foire aux questions (FAQ)


1. Quelle est la fonction principale du module Delta AS64AN02T-A ?

Le Delta AS64AN02T-A sert de module d'extension de sortie numérique haute densité pour l'automate Delta AS Series. Il fournit 64 sorties transistor NPN individuelles, permettant aux systèmes d'automatisation de contrôler un grand nombre de dispositifs externes tels que des actionneurs, des solénoïdes et des voyants lumineux. Cela augmente considérablement la capacité de sortie de l'automate.


Son objectif principal est de permettre des stratégies de contrôle plus complexes et de gérer un plus grand nombre de périphériques de sortie à partir d'un seul châssis d'automate. Ceci est crucial pour les machines comportant de nombreux composants opérationnels nécessitant une activation coordonnée.


This module is essential for applications where the base PLC's output count is insufficient, offering a cost-effective and space-saving solution for system expansion.


2. Quelles sont les principales spécifications techniques du module AS64AN02T-A ?

Ce module dispose de 64 sorties transistor NPN, chacune capable de gérer 0,1 A, avec une limite de courant COM totale de 3,2 A. Il fonctionne dans une plage de tension de 5 à 30 VCC. Le module utilise des connecteurs MIL pour la terminaison, nécessitant généralement des modules de câblage spécifiques.


Il est conçu pour un montage sur rail DIN ou sur châssis et présente une plage de températures de fonctionnement de -20 à 60 degrés Celsius. Son indice de protection IP20 indique qu'il convient aux environnements industriels lorsqu'il est correctement fermé.


The module's specifications are optimized for integration within the Delta AS Series, ensuring compatibility and performance with compatible Delta CPU modules and other expansion units.


3. Comment l'AS64AN02T-A s'intègre-t-il aux autres modules Delta AS Series ?

The AS64AN02T-A is designed to be a direct expansion module within the Delta AS Series PLC system. It connects to the PLC's backplane or a dedicated expansion rack, communicating seamlessly with the CPU module. The AS Series supports up to 32 extension modules, allowing for extensive system growth.


Its modular, rackless design, combined with specialized wiring modules and DIN rail clips, simplifies physical installation and connection. Configuration and programming are managed through Delta's ISPSoft software, which recognizes the module and its I/O points.


This seamless integration ensures that the AS64AN02T-A functions as a natural extension of the PLC's native I/O, maintaining consistent performance and simplifying system design.


4. What types of devices can be controlled by the Delta AS64AN02T-A module's outputs?

Les sorties transistor NPN de l'AS64AN02T-A conviennent au pilotage de dispositifs CC de faible consommation. Cela inclut généralement des solénoïdes pour vannes pneumatiques ou hydrauliques, de petits moteurs à courant continu, des relais (via des relais interposés si nécessaire), des voyants LED et divers types d'actionneurs.


Given the 0.1A per-output rating, it is ideal for devices that do not draw significant current. For higher current loads or AC-powered devices, external relays or solid-state relays controlled by the AS64AN02T-A's outputs would be required.


It's crucial to ensure that the voltage and current requirements of the connected devices fall within the specified operating parameters of the module to prevent damage or malfunction.


5. Quels sont les avantages de l'utilisation d'un module de sortie à 64 points par rapport à des modules plus petits ?

L'utilisation d'un module 64 points comme l'AS64AN02T-A offre des avantages significatifs en termes d'espace et de consolidation du câblage. Il réduit l'encombrement physique dans une armoire de commande par rapport à l'utilisation de plusieurs modules à 8, 16 ou 32 points pour obtenir le même nombre d'E/S.


Cette consolidation conduit également à un câblage simplifié, car moins de modules signifie moins de câbles et de points de terminaison à gérer, ce qui peut réduire le temps d'installation et le risque d'erreurs de câblage.


D'un point de vue économique, un seul module haute densité peut parfois s'avérer plus rentable que l'achat et l'installation de plusieurs modules plus petits, en particulier si l'on considère le coût total de possession, y compris l'espace dans l'armoire et la main d'œuvre.


6. Quelle est la capacité de gestion de la tension et du courant de chaque sortie de l'AS64AN02T-A ?

Chacune des 64 sorties individuelles du module Delta AS64AN02T-A est conçue pour un courant maximum de 0,1 ampère (100 mA). La plage de tension de sortie est comprise entre 5 et 30 VDC. De plus, la borne commune (COM) de ces sorties a une capacité totale de gestion du courant de 3,2 ampères.


Il est essentiel de respecter ces spécifications pour garantir la longévité et le fonctionnement fiable du module et des appareils connectés. Le dépassement de la limite de 0,1 A par sortie peut endommager la sortie du transistor.


La limite de 3,2 A pour le terminal COM partagé signifie que la somme des courants consommés par toutes les sorties actives ne doit pas dépasser cette valeur à un moment donné.


7. Comment le module Delta AS64AN02T-A est-il physiquement installé dans une centrale ?

The AS64AN02T-A module is designed for easy installation, typically using DIN rail mounting clips, which are a standard in industrial control panels. It can also be chassis mounted. The module's robust design ensures secure attachment.


Le câblage vers les appareils externes est réalisé via deux connecteurs MIL à 40 broches. Les utilisateurs emploieront souvent des modules de terminaux de câblage spécialisés qui se connectent à ces connecteurs MIL, fournissant des bornes à vis ou d'autres points de connexion facilement accessibles pour le câblage sur site.


La référence au manuel du matériel de la série Delta AS est cruciale pour comprendre les exigences de câblage spécifiques et les pratiques d'installation recommandées afin de garantir un bon fonctionnement et une bonne sécurité.


8. Can the AS64AN02T-A module be used with PLC systems other than Delta's AS Series?

Non, le Delta AS64AN02T-A est spécifiquement conçu comme module d'extension pour la plate-forme PLC Delta AS Series. Il s'appuie sur le protocole de communication propriétaire et l'architecture de fond de panier de la série AS pour fonctionner correctement avec le module CPU.


L'utilisation de ce module avec un automate d'un autre fabricant ne serait pas possible en raison d'interfaces de communication, de schémas d'adressage et de signalisation électrique incompatibles.


Pour les autres marques d'automates, des modules d'extension équivalents devront provenir de ces fabricants respectifs pour garantir la compatibilité et l'intégrité du système.


9. Quel type de logiciel est utilisé pour programmer et configurer le module AS64AN02T-A ?

The Delta AS64AN02T-A module is configured and programmed using Delta's integrated engineering software, typically ISPSoft. This software suite allows engineers to set up the PLC hardware, define network configurations, develop control logic using ladder diagrams or other supported languages, and manage system diagnostics.


Dans ISPSoft, le module AS64AN02T-A est ajouté à la configuration matérielle et ses 64 points de sortie se voient attribuer des adresses d'E/S qui peuvent ensuite être utilisées dans le programme PLC pour contrôler des périphériques externes.


Le logiciel facilite également le téléchargement du programme sur l'automate, la surveillance en ligne de l'état des E/S et le dépannage, offrant ainsi un environnement complet pour la gestion du système d'automatisation.


10. Existe-t-il des conseils spécifiques de maintenance ou de dépannage pour ce module de sortie ?

Une inspection visuelle périodique du module et de son câblage est recommandée pour vérifier tout signe de dommage, de connexions desserrées ou de contaminants environnementaux. S'assurer que le module fonctionne dans ses limites de température et d'humidité spécifiées est essentiel pour éviter une panne prématurée.


If an output fails to activate or deactivate as expected, verify that the output is correctly addressed in the PLC program and that the output signal from the CPU is being sent. Check the load connected to the output to ensure it is functional and within the module's current and voltage ratings.


Le dépannage implique souvent de vérifier la logique du programme de l'automate, de vérifier l'intégrité du câblage à l'aide d'un multimètre et de s'assurer que le module lui-même est correctement alimenté. Il est également conseillé de consulter le manuel du matériel de la série AS pour connaître les codes d'erreur ou les procédures de diagnostic spécifiques.

Menu