Delta VFD2800C43A-00 C2000+ Advanced Frequency Converter 280kW

stars
  • Availability:In Stock
  • Brand:DELTA
  • Model:VFD2800C43A-00
  • HS: 8504409999
Availability:In Stock
$10070.00
zhongpingtech

The Delta VFD2800C43A-00 C2000+ Advanced Frequency Converter is a powerful 280kW (375 HP) solution designed for demanding industrial applications, offering exceptional motor control, energy savings, and robust performance. Its advanced features, including a high-performance control algorithm, intelligent thermal management, and comprehensive protection functions, position it as a superior choice for optimizing machinery in sectors such as manufacturing, water treatment, and material handling. Key technical specifications include a rated power of 280kW, an output voltage of 400V, and an output current of 510A. The C2000+ series is engineered for precision, reliability, and ease of integration, ensuring maximum operational efficiency and reduced total cost of ownership for industrial users.


| Specification        | Value                                    |

| :------------------- | :--------------------------------------- |

| Model                | VFD2800C43A-00 C2000+                    |

| Rated Power          | 280 kW (375 HP)                          |

| Output Voltage       | 400V                                     |

| Output Current       | 510A                                     |

| Input Voltage        | 3-Phase 380-480V, 50/60Hz                |

| Control Method       | Sensorless Vector Control, V/f Control   |

| Protection Features  | Overload, Overvoltage, Undervoltage, etc. |

| Communication        | Built-in RS-485, Optional Fieldbus Cards |

| Operating Temperature| -20°C to +50°C                           |

| IP Rating            | IP20                                     |


Core Features & Market Positioning


The Delta VFD2800C43A-00 C2000+ distinguishes itself through its sophisticated sensorless vector control, which delivers precise speed and torque regulation even under varying load conditions. This advanced control capability translates into significant energy savings by optimizing motor speed to match actual demand, a critical factor in today's cost-conscious industrial environment. Its robust design incorporates intelligent thermal management systems, including optimized heatsink design and fan control, ensuring reliable operation and extended product life even in harsh industrial settings. Delta's C2000+ series is recognized for its user-friendly interface and comprehensive parameter settings, simplifying commissioning and operation while offering advanced diagnostic capabilities. This combination of high-performance control, energy efficiency, and reliability positions the VFD2800C43A-00 as a leading frequency converter for applications demanding superior motor performance and operational stability.


Key Application Scenarios


This high-capacity frequency converter is exceptionally well-suited for controlling large industrial motors in applications requiring precise speed and torque management. Common scenarios include large pump and fan systems in water and wastewater treatment plants, where precise flow and pressure control directly impacts energy consumption. In the manufacturing sector, it excels in driving conveyors, extruders, and large machine tools, ensuring consistent product quality and efficient production throughput. Material handling systems, such as large cranes and hoists, benefit from the VFD2800C43A-00's smooth acceleration/deceleration profiles and precise load positioning capabilities. Its adaptability also makes it valuable for HVAC systems in large commercial buildings, optimizing air handling and chiller operations for maximum energy efficiency.


Practical System Integration Guidance


Integrating the Delta VFD2800C43A-00 C2000+ into existing systems is streamlined due to its flexible I/O configuration and standard communication protocols. For wiring, ensure all power connections are made according to the terminal diagrams provided in the user manual, paying close attention to grounding and surge protection for reliable operation. The control terminals allow for flexible integration with PLCs and sensors, supporting both digital and analog inputs/outputs for comprehensive system feedback and control. Basic parameter setup involves configuring motor data (poles, rated voltage, current, frequency) and selecting the appropriate control mode (e.g., sensorless vector control for optimal performance). For advanced integration, utilizing the built-in RS-485 communication port or optional fieldbus modules (e.g., Profibus, DeviceNet) enables seamless integration into SCADA and DCS systems for centralized monitoring and control.


Operation and Risk Mitigation


Safe and efficient operation of the Delta VFD2800C43A-00 C2000+ relies on adhering to installation guidelines and understanding its protection features. Always ensure proper ventilation around the drive to prevent overheating, and use appropriate shielded motor cables to minimize electromagnetic interference. Common fault codes, such as 'OC' (Overcurrent) or 'OV' (Overvoltage), typically indicate issues with motor load, acceleration/deceleration times, or power supply stability, requiring a review of application parameters and system conditions. Implement robust emergency stop procedures and ensure personnel are trained on safe shutdown sequences. Regular inspection of connections and heatsink cleanliness will contribute to long-term reliability and prevent unexpected downtime.


Scalability & Long-Term Value


The VFD2800C43A-00 C2000+ offers significant long-term value through its inherent scalability and compatibility with modern industrial automation trends. Its modular design and support for various communication protocols facilitate integration with advanced IIoT platforms, enabling predictive maintenance and remote diagnostics. This facilitates data-driven optimization of industrial processes and reduces operational costs. The drive's ability to control a wide range of motor types and its flexible parameterization ensure it can adapt to evolving production requirements, extending its useful life within dynamic manufacturing environments. By providing precise motor control and substantial energy savings, the C2000+ series contributes directly to operational efficiency and a lower total cost of ownership over the system's lifecycle.


FAQs


What is the primary advantage of the Delta C2000+ series?

The Delta C2000+ series excels in its advanced sensorless vector control. This allows for precise motor speed and torque regulation.

It significantly enhances energy efficiency by matching motor output to the actual load demand. This reduces operational costs.

These drives also offer robust thermal management and comprehensive protection features for high reliability.


How do I perform basic parameter setup for the VFD2800C43A-00?

Start by entering the motor's nameplate data, such as rated power, voltage, current, and frequency. This is critical for accurate control.

Next, select the appropriate control mode, typically sensorless vector control for optimal performance in most applications.

Finally, configure acceleration and deceleration times to match the mechanical system's inertia and operational requirements.


What common fault codes indicate motor issues on this drive?

An 'OC' fault code signifies an overcurrent condition, often related to excessive motor load or rapid acceleration.

An 'OV' fault code indicates an overvoltage condition, which might stem from regenerative energy or unstable power supply.

The 'OL' fault code signifies an overload, meaning the motor is drawing more current than its rated capacity for an extended period.


Can this VFD be integrated with industrial Ethernet networks?

Yes, the Delta VFD2800C43A-00 supports optional communication cards for industrial Ethernet protocols. Examples include EtherNet/IP and Profinet.

This integration allows for seamless data exchange with PLCs and SCADA systems for centralized control and monitoring.

Remote diagnostics and parameter adjustments become feasible, enhancing operational flexibility and maintenance efficiency.


What are the safety precautions during installation of the VFD?

Always ensure the main power supply is completely disconnected and locked out before performing any wiring. Safety first.

Proper grounding of the drive and motor is essential to prevent electrical hazards and reduce electromagnetic interference.

Use shielded motor cables, especially in environments with significant electrical noise, to maintain signal integrity and prevent faults.


How does this frequency converter contribute to energy savings?

It precisely controls motor speed according to the load requirements, avoiding unnecessary energy consumption. This is its core function.

By optimizing motor performance, it reduces overall energy usage compared to fixed-speed motors or simpler VFDs.

The advanced control algorithms ensure maximum efficiency across a wide operating range, leading to substantial cost reductions.


What motor types can the VFD2800C43A-00 control effectively?

This drive is highly effective in controlling standard three-phase induction motors with high efficiency. It is versatile.

It can also be configured for synchronous reluctance motors and permanent magnet synchronous motors for enhanced efficiency.

The drive's flexible parameterization allows for optimization across various motor characteristics and performance demands.


What is the typical operating temperature range for this unit?

The Delta VFD2800C43A-00 is designed to operate reliably within a broad temperature range of -20°C to +50°C. This offers flexibility.

Ensuring adequate ventilation is crucial, especially when operating at the higher end of this range, to maintain optimal performance.

Ambient conditions significantly impact component lifespan, so adhering to these limits is recommended for longevity.


How can I troubleshoot an "OV" (Overvoltage) fault?

Check the input power supply voltage for stability and ensure it is within the drive's specified range. Fluctuations can cause this.

Examine acceleration and deceleration parameters; rapid deceleration on a high-inertia load can generate back EMF.

Consider installing an external braking resistor if the system frequently experiences overvoltage due to excessive regenerative energy.


What is the role of RS-485 communication in this VFD?

The built-in RS-485 port facilitates serial communication with other devices, such as PLCs or HMIs. It's a standard.

This allows for remote monitoring of drive status, parameters, and fault information, simplifying troubleshooting.

It also enables remote control of the drive, including start/stop commands and speed adjustments, enhancing automation.

Menu