Delta VFD4A2MS43ANSAA MS300 Three Phase Motor Speed Control Drive 4.2A 1.5kW

stars
  • Availability:In Stock
  • Brand:DELTA
  • Model:VFD4A2MS43ANSAA
  • HS: 8504409999
Availability:In Stock
$195.60
zhongpingtech

The Delta VFD4A2MS43ANSAA MS300 is a robust three-phase motor speed control drive engineered for demanding industrial applications. This 1.5kW, 4.2A unit offers exceptional performance, energy efficiency, and advanced control capabilities, making it a superior choice for optimizing motor operations. Its compact design, high starting torque, and integrated safety features ensure reliable performance and ease of integration into various automation systems. The MS300 series is recognized for its user-friendly interface, comprehensive protection functions, and compatibility with common industrial communication protocols, positioning it as a leading solution for modern manufacturing environments.


Product Specifications


| Feature               | Specification                                     |

| :-------------------- | :------------------------------------------------ |

| Model                 | VFD4A2MS43ANSAA                                   |

| Series                | MS300                                             |

| Input Voltage         | 3 Phase, 380-480V AC                              |

| Output Capacity       | 1.5 kW (2 HP)                                     |

| Rated Current         | 4.2 A                                             |

| Output Frequency Range | 0.00 Hz to 600.00 Hz                              |

| Control Method        | V/f Control, Vector Control (FLD)                 |

| Braking Unit          | Built-in (up to 11kW/15HP)                        |

| Protection Features   | Overload, Overvoltage, Undervoltage, Overtemperature, etc. |

| Communication Ports   | Optional RS-485 communication module              |

| Operating Temperature | -20°C to 50°C                                     |

| Enclosure             | IP20                                              |


Core Features & Market Positioning


The Delta VFD4A2MS43ANSAA stands out due to its advanced Field Oriented Control (FOC) algorithm, delivering precise speed and torque regulation, even under fluctuating loads. This drive offers significant energy savings through intelligent speed control and optimized power factor management. Its modular design and built-in braking unit simplify installation and reduce the need for external components. Compared to competitors, the MS300 series provides a compelling balance of advanced features, reliability, and cost-effectiveness, making it a preferred choice for SMEs and large enterprises alike seeking enhanced operational efficiency and reduced energy consumption.


Key Application Scenarios


This VFD is ideally suited for a wide array of industrial applications requiring precise motor control. It excels in driving pumps and fans in HVAC systems, where precise flow and pressure regulation are crucial for energy efficiency. In the manufacturing sector, it's commonly employed in conveyor systems, packaging machinery, and machine tools, ensuring smooth operation and accurate product handling. The VFD4A2MS43ANSAA's ability to handle variable loads and provide high starting torque also makes it effective in textile machinery, printing equipment, and material handling systems, contributing to improved process control and productivity.


Practical System Integration Guidance


Integrating the Delta VFD4A2MS43ANSAA into existing systems is straightforward. For power connections, ensure the input power supply matches the drive's specifications (3-Phase, 380-480V AC). Utilize appropriately sized copper wiring for both input and output terminals to handle the rated current of 4.2A. The drive supports standard motor wiring configurations. For control signals, connect digital inputs for start/stop, direction, and speed selection. Analog inputs can be used for speed reference from potentiometers or PLC analog outputs. Optional communication modules, such as RS-485, can be installed for seamless integration with SCADA or PLC systems using protocols like Modbus. Always refer to the VFD's manual for specific wiring diagrams and terminal assignments to prevent damage.


Operation and Risk Mitigation


Safe operation of the Delta VFD4A2MS43ANSAA requires adherence to electrical safety standards and proper commissioning procedures. Before powering up, verify all wiring connections and ensure the motor is correctly sized for the drive's 1.5kW rating. Utilize the drive's built-in protection functions, such as overload (OL) and overvoltage (OV) alarms, by setting appropriate parameters according to motor nameplate data and application requirements. In case of an alarm, consult the operational manual for specific fault codes and troubleshooting steps. For instance, an "OL" fault typically indicates an overload condition that may require reducing the motor load or selecting a higher-rated drive. Proper grounding is essential to prevent electrical hazards and ensure drive longevity.


Scalability & Long-Term Value


The MS300 series offers significant scalability and long-term value within industrial automation architectures. Its compatibility with Delta's broader automation portfolio, including PLCs and HMIs, allows for seamless integration into sophisticated control systems. For evolving IIoT requirements, the optional communication modules enable data logging and remote monitoring capabilities, aligning with Industry 4.0 initiatives. This drive can be easily programmed to adapt to changing production demands or integrated into larger distributed control networks. The inherent energy-saving features and robust construction ensure a lower total cost of ownership over the product's lifespan, providing a sound investment for businesses focused on operational efficiency and sustainability.


Frequently Asked Questions


1. What are the primary benefits of using the Delta VFD4A2MS43ANSAA?

This drive enhances energy efficiency through precise speed control. It offers superior motor protection and reliable operation in demanding environments. The compact design simplifies installation and integration into various industrial setups.


2. How do I connect a motor to the Delta VFD4A2MS43ANSAA?

Connect the motor's three power leads to the drive's U, V, and W output terminals. Ensure the motor is rated for the drive's 1.5kW capacity and 380-480V supply. Verify proper grounding for safety and performance.


3. What kind of motor protection features does this VFD offer?

It includes overload, overvoltage, undervoltage, and overtemperature protection. It also provides motor short-circuit and ground fault protection. These features safeguard both the drive and the motor from damage.


4. Can the Delta VFD4A2MS43ANSAA be used with single-phase motors?

No, this drive is specifically designed for three-phase motors only. It requires a three-phase input power supply to operate correctly. Using it with a single-phase motor will result in damage or malfunction.


5. What is the maximum output frequency for the VFD4A2MS43ANSAA?

The drive supports an output frequency range of 0.00 Hz up to 600.00 Hz. This wide range allows for precise speed control across various applications. Consult the manual for specific application limits.


6. Is it possible to control the motor speed remotely with this drive?

Yes, speed can be controlled remotely using analog inputs or optional communication modules. Analog inputs allow for voltage or current signals. Communication modules enable digital control via protocols like Modbus.


7. What does the "4.2A" rating signify for this VFD?

The 4.2A rating refers to the maximum continuous output current the drive can supply to the motor. It's crucial to match this rating to the motor's full-load amperage (FLA) for optimal performance and longevity.


8. How does the VFD4A2MS43ANSAA handle braking?

This drive features a built-in braking unit for applications requiring rapid deceleration. It can dissipate braking energy safely, preventing overvoltage during motor coast-down or braking operations.


9. What are common fault codes and their meanings for the MS300 series?

Common faults include OL (overload), OV (overvoltage), UV (undervoltage), and OC (overcurrent). Each code indicates a specific issue requiring troubleshooting per the user manual's guidance for resolution.


10. Can this drive integrate with PLCs or SCADA systems?

Absolutely. Integration is easily achieved via standard digital/analog I/O or through optional communication cards. RS-485 with Modbus is a popular choice for connecting to automation systems.