Delta VFD45AMS43ANSAA MS300 High Performance AC Drive Frequency Converter 45A 22kW

stars
  • Availability:In Stock
  • Brand:DELTA
  • Model:VFD45AMS43ANSAA
  • HS: 8504409999
Availability:In Stock
$780.20
zhongpingtech

The Delta VFD45AMS43ANSAA MS300 High-Performance AC Drive is engineered for demanding industrial applications, delivering exceptional control and energy efficiency for motor-driven systems. This 45A, 22kW frequency converter stands out with its advanced features, robust design, and user-friendly interface, making it a superior choice for optimizing machinery performance across various sectors. Key advantages include its high starting torque, precise speed regulation, and comprehensive protection capabilities, ensuring reliable operation and extended equipment lifespan.


Product Specifications


| Feature                     | Specification                               |

| :-------------------------- | :------------------------------------------ |

| Model                       | VFD45AMS43ANSAA                             |

| Series                      | MS300                                       |

| Rated Output Capacity       | 22 kW (30 HP)                               |

| Rated Output Current        | 45 A                                        |

| Input Voltage               | 3-Phase, 380-480V AC, 50/60 Hz              |

| Output Frequency Range      | 0 Hz to 1000 Hz                               |

| Control Method              | Sensorless Vector Control, V/f Control      |

| Protection Level            | IP20                                        |

| Communication Interfaces    | RS-485 (Modbus)                             |

| Braking Unit                | Built-in (Resistor not included)            |

| Dimensions (H x W x D)      | 260 x 185 x 175 mm                          |

| Ambient Temperature Range   | -20°C to +50°C                              |


Core Features & Market Positioning


The Delta VFD45AMS43ANSAA MS300 drive distinguishes itself in the competitive AC drive market through its advanced sensorless vector control, which provides superior torque performance and accuracy without the need for encoder feedback. This technology significantly simplifies installation and reduces system costs while maintaining precise motor speed regulation, even under fluctuating load conditions. Its compact design and integrated braking unit offer enhanced flexibility for panel mounting and space-constrained environments, positioning it as a high-value solution for system integrators and end-users seeking robust, efficient, and reliable motor control.


Key Application Scenarios


This high-performance AC drive is ideally suited for a broad spectrum of industrial applications where precise motor control and energy savings are paramount. It excels in machinery such as conveyors, pumps, fans, extruders, and machine tools, delivering consistent performance and optimizing energy consumption. The drive's ability to handle high starting torque makes it particularly effective for applications with frequent starts and stops or heavy inertia loads, ensuring smooth acceleration and deceleration. Industries benefiting from the VFD45AMS43ANSAA include manufacturing, material handling, water treatment, and general automation, where its reliability and advanced control algorithms contribute to increased productivity and reduced operational expenses.


Practical System Integration Guidance


Integrating the Delta VFD45AMS43ANSAA is streamlined due to its intuitive parameter settings and robust communication capabilities. Wiring should adhere to local electrical codes, with proper grounding and shielding of motor and communication cables to prevent electromagnetic interference. The drive supports RS-485 Modbus communication, facilitating seamless integration into SCADA systems and PLCs for remote monitoring and control. Commissioning typically involves setting basic motor parameters (voltage, current, frequency, poles) and selecting the appropriate control mode (e.g., V/f or sensorless vector) based on application requirements. Delta's Drive Tool software can further assist in parameter configuration, diagnostics, and firmware updates, simplifying the setup process.


Operation and Risk Mitigation


Safe operation of the Delta VFD45AMS43ANSAA requires adherence to the manufacturer's guidelines and proper training for personnel. Ensure all power is disconnected before performing any wiring or maintenance. The drive incorporates comprehensive protection features, including over-current, over-voltage, under-voltage, overload, and overheat protection, which automatically safeguard the motor and the drive itself. Critical fault codes, such as E.OL (Overload) or E.OC (Over-current), should be addressed by investigating the cause of the fault—whether it's an excessive load, improper parameter settings, or external wiring issues—before resetting the drive. Regular inspection of ventilation and external components is recommended to maintain optimal operating conditions and prevent premature failure.


Scalability & Long-Term Value


The VFD45AMS43ANSAA offers significant long-term value through its compatibility with Delta's broader automation ecosystem and its inherent energy-saving capabilities. While the MS300 series is designed for standalone or basic networked applications, its robust performance contributes to reduced wear on mechanical components, extending equipment life and minimizing maintenance costs. For more complex integrations or advanced IIoT functionalities, Delta provides other drive series and complementary products, such as PLCs and HMIs, that can be integrated into a unified control architecture. This ensures that the initial investment in the VFD45AMS43ANSAA can be part of a scalable, future-proof automation strategy.


Frequently Asked Questions


What is the maximum overload capacity of the Delta VFD45AMS43ANSAA?

The Delta VFD45AMS43ANSAA typically supports a 150% overload for 60 seconds, allowing it to handle transient high torque demands. This capability is crucial for applications with high inertia or sudden load increases. It ensures the drive can manage short-term overloads without tripping protective functions.


How do I connect an external braking resistor to the VFD45AMS43ANSAA?

Connect the braking resistor to the dedicated brake terminals (B1, B2) on the drive. Ensure the resistor's power rating and resistance value are compatible with the drive's specifications to prevent damage. Consult the user manual for the precise wiring diagram and resistance range recommendations.


Can the Delta VFD45AMS43ANSAA be used with single-phase motors?

No, the Delta VFD45AMS43ANSAA is designed exclusively for three-phase motors. It requires a three-phase input power supply and outputs a three-phase variable frequency output to control three-phase induction motors. Using it with a single-phase motor will cause damage.


What communication protocol does the VFD45AMS43ANSAA support for remote control?

The VFD45AMS43ANSAA supports the Modbus RTU protocol via its built-in RS-485 communication interface. This allows for easy integration with PLCs, HMIs, and SCADA systems for remote monitoring, parameter adjustment, and command control. It enables efficient data exchange in automated environments.


What is the typical energy saving achieved with this drive?

Energy savings vary significantly based on the application and load profile. For variable torque loads like fans and pumps, savings can range from 20% to 60% by matching motor speed to system demand. The drive optimizes power consumption by reducing motor speed when full output is not required.


How do I perform a factory reset on the VFD45AMS43ANSAA?

A factory reset is typically performed by accessing parameter P00.10 and setting it to the appropriate value, usually '1' or '2', to restore factory default settings. Always record your current settings before performing a reset, as all custom parameters will be lost.


What are the dimensions and mounting requirements for the VFD45AMS43ANSAA?

The drive has dimensions of 260mm (H) x 185mm (W) x 175mm (D) and an IP20 protection rating. It requires adequate ventilation clearance on all sides, typically 50mm for top/bottom and 20mm for side, for proper heat dissipation. It's designed for vertical panel mounting.


What is sensorless vector control and why is it beneficial?

Sensorless vector control allows the drive to accurately control motor speed and torque without requiring an encoder feedback device. This simplifies installation, reduces cost, and improves reliability. It's highly effective for applications needing precise speed regulation under varying loads.


Does the VFD45AMS43ANSAA come with a built-in braking unit?

Yes, the VFD45AMS43ANSAA features a built-in braking unit. This unit allows for dynamic braking by dissipating excess energy into an external braking resistor during deceleration, helping to stop the motor quickly and safely. The resistor itself is usually sold separately.


What is the maximum output frequency for the VFD45AMS43ANSAA?

The VFD45AMS43ANSAA can operate with an output frequency range from 0 Hz up to 1000 Hz. This wide frequency range provides flexibility for high-speed applications or processes requiring very slow motor speeds, offering precise control across diverse operational demands.

Menu