DANFOSS FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX 1.5kW 3.7A Three Phase 480V IP55 VFD

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$701.40
zhongpingtech

The DANFOSS FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX is a high-performance 1.5kW, three-phase, 480V Variable Frequency Drive (VFD) with an IP55 enclosure, designed for robust industrial applications. This VFD offers precise motor control, energy savings, and enhanced operational efficiency. Key advantages include its compact design, ease of integration, and advanced protection features. With a 1.5kW power rating, 3.7A current handling, and 480V operating voltage, the FC-101 series is engineered for reliability and superior performance in demanding environments.


| Feature/Parameter        | Specification                               |

| :----------------------- | :------------------------------------------ |

| Product Number           | FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX      |

| Power Rating             | 1.5 kW                                      |

| Rated Current            | 3.7 A                                       |

| Phase                    | Three Phase                                 |

| Voltage                  | 480V                                        |

| Enclosure Protection     | IP55                                        |

| Control Type             | V/f Control, Vector Control (optional)      |

| Ambient Temperature      | -10°C to 50°C (derating may apply)          |

| Altitude                 | Up to 1000m without derating                |

| Overload Capacity        | 110% for 60s, 150% for 10s                  |

| Communication Options    | Modbus RTU, Profibus DP, DeviceNet (optional)|


Core Features & Market Positioning


The DANFOSS FC-101 series distinguishes itself through its advanced V/f control, offering excellent motor speed regulation for a wide array of industrial motors. Its robust IP55 enclosure ensures reliable operation even in dusty or wet conditions, a critical factor in many manufacturing and processing plants. Positioned as a cost-effective yet highly capable solution, the FC-101 series provides essential VFD functionalities without compromising on Danfoss's renowned quality and durability. This makes it a strong contender for applications requiring dependable motor control and energy optimization in environments where standard drives might falter.


Key Application Scenarios


This 1.5kW VFD is exceptionally well-suited for applications such as conveyor systems, pumps, fans, and general-purpose machinery. Its three-phase, 480V configuration makes it ideal for North American industrial settings. The IP55 rating is particularly advantageous for use in food and beverage processing, chemical plants, and outdoor installations where environmental protection is paramount. Precise speed control also contributes to reduced wear on machinery, extending equipment life in continuous operation scenarios.


Practical System Integration Guidance


Integrating the DANFOSS FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX involves careful attention to wiring and parameter setup. For three-phase motor connections, ensure proper grounding and torque all terminal screws to the recommended specifications. Power supply wiring should adhere to local electrical codes and the drive's manual. Initial commissioning typically requires setting motor nameplate data, desired acceleration/deceleration times, and control modes. For advanced integration, utilizing the available communication options like Modbus RTU allows for seamless inclusion into SCADA systems or PLCs for remote monitoring and control.


Operation and Risk Mitigation


Operating the FC-101 VFD safely requires adherence to all electrical safety standards. Ensure the drive is properly grounded and that all power is disconnected before performing any wiring or maintenance. Key parameters to monitor for optimal operation include motor temperature, drive temperature, and input voltage. Common error codes, such as 'Overcurrent' (F001) or 'Overvoltage' (F002), typically indicate issues with motor load, cabling, or power supply quality, requiring prompt investigation and resolution to prevent damage.


Scalability & Long-Term Value


The DANFOSS FC-101 series offers significant long-term value through its energy-saving capabilities and compatibility with a wide range of automation platforms. While not designed for extensive internal hardware upgrades, its scalability is primarily achieved through external integration. The availability of communication option cards facilitates its connection to modern IIoT infrastructure, enabling advanced diagnostics and predictive maintenance strategies. This ensures that the drive remains a relevant and valuable component within evolving industrial automation ecosystems.


Frequently Asked Questions


Q1: What are the primary benefits of using the DANFOSS FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX?

The DANFOSS FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX offers significant energy savings by precisely controlling motor speed. It enhances operational efficiency and reduces mechanical stress on equipment. The IP55 rating ensures robust protection against dust and water ingress, crucial for industrial environments.


Q2: Can this VFD be used with any three-phase motor?

Yes, this VFD is designed for use with standard three-phase induction motors. It is essential to match the motor's power and current ratings to the VFD's specifications. Proper parameter configuration based on motor nameplate data is critical for optimal performance and protection.


Q3: What is the significance of the IP55 rating on this Danfoss VFD?

An IP55 rating means the VFD is protected against dust ingress and is resistant to water jets from any direction. This makes it suitable for installation in challenging industrial settings where exposure to dust, moisture, or hosing down is common.


Q4: How do I connect a motor to the DANFOSS FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX?

Connect the three motor leads (U, V, W) to the corresponding terminals on the VFD. Ensure proper grounding of both the motor and the VFD. Follow the wiring diagrams in the product manual meticulously, paying attention to terminal torque specifications.


Q5: What are typical troubleshooting steps for common error codes on this drive?

For overcurrent faults, check for motor overload or short circuits in cabling. For overvoltage faults, investigate the incoming power supply stability. Always refer to the drive's manual for a complete list of error codes and their specific solutions.


Q6: Does this VFD support advanced control methods like vector control?

The FC-101 series primarily features V/f control for general applications. While some models might support advanced control, it's crucial to verify the specific variant's capabilities. Consult the product documentation for detailed control mode information.


Q7: What are the recommended installation considerations for the DANFOSS FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX?

Install the VFD in a well-ventilated area, avoiding direct sunlight and high ambient temperatures. Ensure sufficient clearance for airflow around the drive. Mount it vertically on a DIN rail or wall, following the specified mounting guidelines to ensure proper heat dissipation.


Q8: How can I integrate this VFD into an existing automation system?

Integration is typically achieved via communication protocols like Modbus RTU, Profibus DP, or DeviceNet, depending on the installed option cards. This allows for remote control, monitoring of operational data, and alarm management within a SCADA or PLC system.


Q9: What is the maximum ambient operating temperature for this drive?

The DANFOSS FC-101 series typically operates within an ambient temperature range of -10°C to 50°C. However, derating of the VFD's current output may be necessary at higher temperatures or altitudes above 1000m.


Q10: Where can I find the user manual and technical documentation for this specific model?

Official user manuals and detailed technical specifications for the DANFOSS FC-101P1K5T4E5AH2XAXXXXSXXXXAXBXCXXXXDX can be found on the Danfoss website. Searching for the product number on their support portal will provide access to all relevant documentation.

Menu