The DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX, a 2.2kW VLT HVAC Drive, stands as a robust solution for demanding building automation applications. This 3-phase AC drive, operating at 480V and boasting an IP55 enclosure, delivers precise motor control with a maximum current of 5.3A. Its core advantages lie in energy efficiency, advanced control capabilities, and simplified integration within HVAC systems, making it a preferred choice for optimizing heating, ventilation, and air conditioning performance. The drive's compact design and comprehensive feature set ensure seamless operation and contribute to significant operational cost savings.
| Parameter | Value |
| :------------------------- | :--------------------------------------- |
| Product Number | FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX |
| Power Rating | 2.2 kW |
| Maximum Current | 5.3 A |
| Voltage | 3-Phase AC 480V |
| Enclosure Rating | IP55 |
| Type | VLT HVAC Drive |
The DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX distinguishes itself through its specialized HVAC functionalities and superior motor performance. Its variable speed drive technology allows for precise regulation of fan and pump speeds, directly translating to reduced energy consumption compared to traditional fixed-speed systems. The drive's advanced control algorithms ensure stable system operation, minimizing mechanical stress on equipment and extending its lifespan. Its market positioning is firmly established as a reliable, energy-efficient, and user-friendly variable frequency drive for a wide array of HVAC applications.
Key application scenarios for the DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX include controlling variable air volume (VAV) systems, managing water circulation pumps in heating and cooling loops, and operating exhaust fans in commercial buildings. Its robust IP55 rating makes it suitable for installation in environments where dust and water ingress are potential concerns, such as mechanical rooms or outdoors with appropriate protection. The drive is engineered to optimize performance in applications requiring precise temperature and pressure control, ensuring occupant comfort while maximizing energy savings.
Practical system integration of the DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX involves straightforward wiring and commissioning processes. The drive accepts standard 3-phase AC power input and provides controlled output to the motor. Recommended wiring practices include using appropriately sized conductors and ensuring proper grounding to prevent electrical interference and ensure safety. Commissioning typically involves parameter setting to match the specific motor and application requirements, such as setting acceleration/deceleration ramps, maximum/minimum speed limits, and utilizing built-in PID controllers for closed-loop operations.
Operation and risk mitigation for the DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX prioritize safety and system stability. Users should adhere to all electrical safety guidelines during installation and maintenance, including ensuring the drive is de-energized before performing any physical connections. Common troubleshooting involves checking power supply integrity, motor connections, and parameter settings. Critical fault codes, such as overcurrent or overheating, are typically indicated on the drive's display and are thoroughly documented in the product manual, providing clear guidance for resolution.
Scalability and long-term value are inherent in the DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX. The VLT HVAC Drive platform is designed for compatibility with various building management systems (BMS) and industrial communication protocols, allowing for seamless integration into existing or future smart building infrastructures. This facilitates advanced monitoring, diagnostics, and remote control capabilities, supporting the transition towards Industrial Internet of Things (IIoT) and digitalized facility management. The drive's robust construction and energy-saving features contribute to a low total cost of ownership over its operational life.
*
Frequently Asked Questions
What is the power rating of the DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX?
The DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX features a robust 2.2 kW power rating. This capacity is well-suited for a variety of HVAC motor applications. It ensures ample power for demanding fan and pump operations.
This drive is designed for efficient energy conversion and delivery. It optimizes motor performance across its operating speed range. The 2.2 kW rating provides a balance of power and efficiency for many commercial buildings.
The specific power output ensures reliable operation for connected equipment. It meets the requirements for many standard HVAC system components. This power level contributes to overall system stability and performance.
What is the maximum current handling capacity of this VLT HVAC Drive?
The DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX is rated for a maximum current of 5.3 Amperes. This specification is critical for proper motor and drive sizing. It ensures the drive can safely handle the motor's demands.
This current rating is essential for preventing overload conditions. It guarantees the drive operates within its thermal limits during peak performance. Proper cable sizing must correlate with this current capacity.
Understanding the 5.3A limit is key for system designers. It informs the selection of protective devices and wiring. It ensures the drive's longevity and system reliability.
Can the DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX be used in outdoor or dusty environments?
Yes, the DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX boasts an IP55 enclosure rating. This signifies protection against dust ingress and low-pressure water jets. It is designed for resilience in challenging conditions.
The IP55 classification allows for installation in areas with moderate dust accumulation and occasional water exposure. This makes it suitable for many mechanical room and some sheltered outdoor applications. Always ensure local environmental regulations are met.
While rated IP55, it is still advisable to provide additional protection from direct heavy rain or extreme weather. Proper installation practices are paramount for maintaining the integrity of the enclosure. Consult the manual for specific environmental guidelines.
What type of power supply does this drive require?
This VLT HVAC Drive operates on a 3-phase AC power supply. The specific voltage requirement is 480 Volts. This is a common power standard in many industrial and commercial settings.
Ensuring a stable and correctly phased 3-phase 480V supply is crucial for optimal performance. Incorrect voltage or phasing can lead to drive malfunction or damage. Verify the supply before connecting.
The drive is engineered to efficiently convert this incoming power into variable frequency and voltage for motor control. It requires a dedicated and appropriately protected power circuit. Always follow local electrical codes for installation.
What are the primary benefits of using a VLT HVAC Drive like the FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX?
A primary benefit is significant energy savings through variable speed control. This drive precisely matches motor speed to system demand, reducing wasted energy. It leads to lower electricity bills and a reduced carbon footprint.
Another key advantage is enhanced system performance and comfort. By precisely controlling fans and pumps, it maintains stable temperatures and airflows. This reduces noise, vibration, and wear on mechanical components.
Furthermore, these drives simplify system integration and offer advanced control features. They often include built-in PID controllers and communication options for BMS integration. This leads to improved operational efficiency and diagnostics.
What industries commonly utilize the DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX?
This drive is predominantly used within the commercial building sector. It is essential for managing HVAC systems in office buildings, hospitals, and retail spaces. Its focus is on optimizing comfort and energy usage.
Industrial facilities also benefit from its capabilities, particularly those with extensive ventilation or pumping requirements. Manufacturing plants and process industries employ it for precise environmental control and operational efficiency. It supports critical air and fluid handling functions.
Wastewater treatment plants and water supply utilities are other key sectors. Here, the drive efficiently controls pumps for water circulation and effluent management. Its reliability and efficiency are crucial in these continuous operation environments.
How does the IP55 rating benefit system integration?
The IP55 rating provides a moderate level of protection against dust and water. This allows for more flexible installation locations within buildings. It can be installed in areas prone to dust or occasional moisture without immediate risk.
This robustness reduces the need for extensive protective enclosures in many applications. It simplifies wiring and maintenance access compared to drives requiring fully sealed cabinets. This can lead to lower installation costs.
It ensures the drive can withstand typical conditions found in plant rooms or mechanical spaces. This reliability contributes to longer operational life and fewer service interruptions. It makes the drive a practical choice for diverse environments.
What type of motors can be controlled by this DANFOSS drive?
The DANFOSS FC-101P2K2T4E5AH2XAXXXXSXXXXAXBXCXXXXDX is designed to control standard 3-phase AC induction motors. These are the most common type of motors used in HVAC applications. It ensures broad compatibility.
The drive's control algorithms are optimized for these motors. It provides efficient speed and torque control for optimal performance. It can manage motor starting and stopping sequences effectively.
For optimal results, motor nameplate data should be entered into the drive's parameters. This allows the drive to fine-tune its control for the specific motor characteristics. Proper motor selection is still a prerequisite for successful integration.
What are common troubleshooting steps for issues with this drive?
Begin by checking the incoming power supply. Ensure it is stable, at the correct voltage, and properly phased. Verify all motor connections are secure and free from shorts.
Next, review the drive's error codes and status indicators on the display. Consult the product manual to interpret any displayed fault codes. Many issues relate to incorrect parameter settings for the application or motor.
Confirm that the motor itself is functioning correctly and is properly sized for the load. Overloads or mechanical binding can trigger drive protection. Basic maintenance like ensuring cooling fins are clear of debris is also important.
How does this drive contribute to long-term value in an HVAC system?
It significantly reduces operational costs through energy efficiency. By optimizing motor speed, it lowers electricity consumption considerably. This direct cost saving contributes to a faster return on investment.
The precise motor control also minimizes mechanical stress on equipment. This leads to extended lifespan for pumps, fans, and associated components. Reduced wear and tear means lower maintenance and replacement expenses over time.
Its integration capabilities with BMS and IIoT platforms enable advanced system management. This allows for predictive maintenance and remote optimization, further enhancing operational efficiency and value. The drive becomes a key component of a smart, sustainable building.