DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX 45kW 90A Three Phase 480V IP55 VFD

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$4522.80
zhongpingtech

The DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX 45kW 90A Three Phase 480V IP55 VFD is a robust and versatile variable frequency drive engineered for demanding industrial applications. This drive offers significant advantages, including enhanced energy efficiency, precise motor control, and exceptional reliability, making it a cornerstone for optimizing operational performance. Its core features are centered around advanced control algorithms and a rugged construction designed for harsh environments. Key technical parameters include a substantial power rating of 45kW, a maximum output current of 90A, and an operating voltage of three-phase 480V. The IP55 enclosure rating signifies excellent protection against dust and water ingress, ensuring dependable operation in challenging industrial settings.


Product Specifications


| Feature                | Specification                                      |

| :--------------------- | :------------------------------------------------- |

| Model Number           | FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX            |

| Power Rating           | 45 kW                                              |

| Maximum Output Current | 90 A                                               |

| Phase                  | Three Phase                                        |

| Voltage                | 480 V                                              |

| Enclosure Rating       | IP55                                               |

| Control Type           | Variable Frequency Drive (VFD)                     |


Core Features & Market Positioning


The DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX stands out in the industrial automation market due to its advanced VLT® platform technology, which delivers superior motor control performance and energy savings. Its positioning is that of a reliable, high-performance drive for variable torque and constant torque applications, offering a compelling balance of functionality and cost-effectiveness. The integrated functional safety features, such as safe torque off (STO), further enhance its market appeal for applications where personnel and equipment safety are paramount. This drive is engineered to minimize harmonic distortion, contributing to cleaner power grids and reduced operational costs, a critical consideration for modern industrial facilities.


Key Application Scenarios


This 45kW VFD is ideally suited for a wide array of industrial applications, including pump and fan control, conveyors, extruders, and general-purpose machinery. Its ability to precisely control motor speed makes it invaluable in HVAC systems for optimizing airflow and energy consumption. In process industries, the DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX provides the necessary torque and speed regulation for mixers, agitators, and material handling equipment. The IP55 rating ensures its suitability for environments with dust and moisture, such as food and beverage processing, chemical plants, and manufacturing floors.


Practical System Integration Guidance


Integrating the DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX into existing systems is streamlined through its user-friendly interface and robust connectivity options. Proper installation involves ensuring adequate ventilation around the IP55 enclosure to maintain optimal operating temperatures. Wiring connections for the three-phase 480V supply and motor should adhere strictly to local electrical codes and the drive's manual. Commissioning typically involves parameter configuration, including setting motor data, ramp times, and control modes (e.g., V/f, vector control) to match the specific application requirements. The drive's digital and analog I/O can be easily programmed to interface with PLCs and other control system components.


Operation and Risk Mitigation


Safe operation of the DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX is paramount. Before commissioning, ensure all safety guards are in place and that personnel are trained on the VFD's operation and emergency stop procedures. Key risk mitigation strategies include implementing the Safe Torque Off (STO) function to prevent unexpected motor starts. Regular maintenance, such as cleaning the enclosure vents and checking electrical connections, helps prevent operational failures. Common fault codes, which are detailed in the product manual, provide diagnostic information to address issues such as overcurrent, overvoltage, or motor thermal overload, allowing for quick troubleshooting and minimizing downtime.


Scalability & Long-Term Value


The DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX offers significant long-term value through its scalability and integration capabilities. Its compatibility with various communication protocols (e.g., Modbus, Profibus, if applicable via options) allows for seamless integration into supervisory control and data acquisition (SCADA) systems and Industrial Internet of Things (IIoT) platforms, enabling advanced data monitoring and predictive maintenance. The Danfoss VLT® platform is designed for future-proofing, allowing for software updates and the addition of option cards to adapt to evolving industrial demands. This ensures that the investment in this VFD provides lasting benefits and supports the modernization of industrial processes.


Frequently Asked Questions


What is the primary function of the DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX VFD?

The primary function is to control the speed and torque of three-phase AC motors. It achieves this by varying the frequency and voltage supplied to the motor, enabling precise control over its operation. This leads to significant energy savings in applications like pumps and fans.


This VFD allows for smooth starting and stopping of motors, reducing mechanical stress on equipment. It also provides protection features to safeguard the motor and the drive itself from electrical faults and overloads.


By precisely matching motor output to process demand, it optimizes system efficiency and reduces wear and tear on machinery. This results in lower operational costs and extended equipment lifespan.


How do I connect a motor to the DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX?

Connect the three motor leads (U, V, W) to the corresponding output terminals on the VFD. Ensure proper grounding of both the motor and the VFD unit for safety and performance. Always disconnect power before making any wiring connections.


Refer to the installation manual for specific terminal designations and recommended cable types and sizes. Incorrect wiring can lead to drive damage or motor failure.


The VFD also has input terminals for power supply (L1, L2, L3) and control signals. Double-check all connections for tightness and correct phasing.


What are the benefits of the IP55 rating on this VFD?

The IP55 rating means the drive is protected against dust ingress and low-pressure water jets from any direction. This makes it suitable for installation in many industrial environments where dust or moisture may be present.


This enclosure protection ensures reliable operation and longevity in challenging conditions, reducing the risk of equipment failure due to environmental factors. It minimizes the need for additional protective enclosures in many settings.


Environments like food processing plants, manufacturing floors, or areas with wash-down procedures can benefit from this robust protection. It simplifies installation by offering built-in resilience.


Can this VFD be used for pump applications?

Yes, this VFD is excellent for pump applications, offering precise flow control and significant energy savings. It allows for variable speed operation, matching pump output to system demand.


By controlling pump speed, it eliminates the need for throttling valves, which are inefficient. This leads to reduced energy consumption and smoother system operation.


The drive can protect the pump from issues like dry running (with appropriate sensors) and water hammer effects through controlled acceleration and deceleration profiles.


What is the maximum output current of the DANFOSS FC-101P45KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX?

The maximum continuous output current for this VFD is 90 Amperes. This rating determines the size of the motor it can effectively control.


This current rating is crucial for selecting the correct VFD for a specific motor load. Exceeding this limit can lead to drive overload and potential failure.


Ensure the motor's full load amperage (FLA) is within the VFD's continuous current capacity for reliable and safe operation.


How does the VFD improve energy efficiency?

The VFD improves energy efficiency by allowing motor speed to be adjusted to match the actual load requirement. Instead of running at full speed and throttling output, the motor runs only as fast as needed.


For centrifugal loads like fans and pumps, power consumption is proportional to the cube of the speed. Reducing speed slightly can result in substantial energy savings.


This precise control avoids wasted energy, leading to lower electricity bills and a reduced carbon footprint for industrial operations.


What does "Three Phase 480V" mean for this VFD?

"Three Phase 480V" indicates that the VFD is designed to be powered by a three-phase electrical supply at a nominal voltage of 480 Volts. This is a common industrial power standard in many regions.


This means it requires a three-wire (plus ground) AC power source where all three phases are utilized for operation. It is not compatible with single-phase power supplies.


The drive's output also provides a three-phase power waveform to the motor, allowing it to run efficiently and with high performance.


What is the Safe Torque Off (STO) feature?

Safe Torque Off (STO) is a crucial safety function that safely disconnects the motor from the power supply, preventing it from generating torque. It is a built-in safety measure to stop motion rapidly and safely.


When activated, STO ensures that the motor cannot be started unintentionally, providing a safe state for maintenance or emergency situations. It is a fundamental part of functional safety in industrial machinery.


This feature adheres to safety standards and allows for safe interaction with machinery without the need for mechanical disconnects in many scenarios.


How do I program parameters on this VFD?

Programming parameters is typically done via the VFD's built-in control panel or through PC-based software. The control panel usually features a display and navigation buttons.


You will need to access the parameter menus to configure settings like motor data, ramp times, control modes, and I/O assignments. Consult the user manual for detailed instructions.


For complex configurations or remote programming, software tools like Danfoss's software can be utilized, often connecting via a serial port or network interface.


What are common troubleshooting steps for VFD faults?

Common troubleshooting involves checking error codes displayed on the VFD, consulting the manual for fault descriptions, and verifying power supply and motor connections. Ensure parameters are correctly configured for the application.


Inspect for any physical damage, loose wiring, or environmental issues like overheating or excessive dust. Reset the drive after addressing the fault condition if appropriate.


If the fault persists, consider checking motor winding insulation and continuity, and if necessary, contact technical support for further assistance.