DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX 11kW VLT AutomationDrive FC-302 3AC 500V

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$2299.20
zhongpingtech

The DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX 11kW VLT AutomationDrive FC-302 is a robust variable frequency drive engineered for demanding industrial applications. Its core advantages lie in exceptional energy efficiency, precise motor control, and superior reliability, making it a leading choice for optimizing pump, fan, and general machine performance. Key technical parameters include its 11kW power rating, 3-phase AC input, 500V operating voltage, and advanced control capabilities designed to reduce operational costs and enhance process throughput.


DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX: A Deep Dive into Performance and Application


The DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX, a prominent member of the VLT AutomationDrive FC-302 series, stands out in the industrial automation landscape for its powerful performance and advanced features. This 11kW, 3-phase AC, 500V drive is engineered to deliver unparalleled efficiency and precise control over a wide range of motor applications. Its design prioritizes reliability and ease of integration, positioning it as a cost-effective and high-performance solution for modern industrial operations.


Product Specifications


| Parameter                | Value                                         |

| :----------------------- | :-------------------------------------------- |

| Model Number             | FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX        |

| Power Rating             | 11 kW                                         |

| Input Voltage            | 3 Phase AC, 500V                              |

| Series                   | VLT AutomationDrive FC-302                    |

| Enclosure Rating         | IP21 (Standard, though options exist)         |

| Maximum Output Current   | 23 A                                          |

| Control Type             | V/f, Vector Control (with optional encoder)   |

| Braking Options          | Integrated DC bus, external braking resistor  |

| Communication Options    | Fieldbus modules (e.g., Profibus, EtherNet/IP) |

| Operating Temperature    | -20°C to +50°C (derating may apply)           |


Core Features & Market Positioning


The DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX excels through its advanced control algorithms, offering both V/f and advanced vector control modes. This versatility allows for optimized performance across various motor types and load profiles, from simple fan applications to highly dynamic process machinery. Its robust construction and high-quality components ensure extended service life and minimal downtime, even in harsh industrial environments. The drive's inherent energy-saving capabilities, particularly at partial loads, significantly reduce electricity consumption, directly impacting operational expenditure. Danfoss's reputation for reliable automation solutions further solidifies the FC-302's market position as a dependable and future-proof investment.


Key Application Scenarios


The versatility of the DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX makes it suitable for a broad spectrum of industrial applications. It is a prime choice for controlling pumps in water treatment plants, HVAC systems, and agricultural irrigation, where precise flow and pressure management are critical. In manufacturing, it effectively manages conveyor systems, mixers, extruders, and machine tools, enabling smooth acceleration, deceleration, and speed regulation. The drive's ability to handle demanding loads and its energy efficiency also make it ideal for applications in the oil and gas sector, food and beverage processing, and general material handling.


Practical System Integration Guidance


Integrating the DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX into existing systems is streamlined by its flexible design. For power connections, ensure the input power supply (3-phase, 500V AC) is correctly wired to the L1, L2, L3 terminals, adhering to local electrical codes and safety standards. Motor connections should be made to U, V, W. Proper grounding is essential for safety and performance; connect the protective earth (PE) terminal to the system ground. For advanced control and communication, install appropriate fieldbus modules (e.g., for Profibus DP or EtherNet/IP) in the designated slots. Initial commissioning typically involves setting motor parameters such as nominal power, voltage, current, and frequency, as well as configuring I/O settings and desired control modes via the drive's keypad or programming software (like Danfoss MCT 10).


Operation and Risk Mitigation


Safe operation of the DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX requires adherence to the manufacturer's guidelines. Before powering up, verify all connections and ensure the drive is properly earthed. During operation, avoid touching terminals when the drive is powered. For stopping, it's recommended to use ramp-to-stop functions rather than immediate power cuts, unless an emergency stop is required. Common fault codes, such as "Overcurrent" (F001) or "Overtemperature" (F004), often indicate issues with motor load, cabling, or ambient conditions. Troubleshooting typically involves checking motor and load compatibility, verifying supply voltage, and ensuring adequate ventilation. Always consult the user manual for specific fault code interpretations and resolution steps.


Scalability & Long-Term Value


The VLT AutomationDrive FC-302 series, including the FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX, offers excellent scalability and long-term value. Its modular design facilitates the addition of various option cards for enhanced communication protocols or I/O expansion, allowing systems to adapt to evolving operational requirements. Compatibility with Danfoss's broader ecosystem of automation products and services ensures seamless integration into larger control architectures. Furthermore, the drive's robust firmware can often be updated to incorporate new features or performance enhancements, extending its operational lifespan and future-proofing investments. Integration with Industrial Internet of Things (IIoT) platforms is achievable through compatible fieldbus interfaces, enabling remote monitoring, diagnostics, and predictive maintenance strategies.


Frequently Asked Questions


What are the primary benefits of using the DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX?


The primary benefits include significant energy savings through precise speed control. It also offers enhanced motor protection features, extending equipment lifespan. The drive's robust design ensures high reliability in demanding industrial settings.


How does the DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX handle different motor types?


This drive supports both V/f control for simpler applications. For more demanding tasks, it offers advanced vector control for superior torque and speed accuracy. It can be configured for various motor technologies.


What are the typical applications for this 11kW VLT AutomationDrive?


This drive is ideal for pumps, fans, and general machinery in HVAC, water, and manufacturing. It’s also used in conveyors, mixers, and extruders. Its versatility suits many process industries.


What input voltage is required for the FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX?


The drive requires a 3-phase AC input voltage of 500V. It is crucial to ensure your power supply matches this specification for safe and efficient operation. Always confirm local supply compatibility.


Can the DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX be programmed remotely?


Yes, remote programming is possible via installed fieldbus communication modules. This allows for system integration and remote parameter adjustments. It simplifies commissioning and maintenance tasks.


What safety features are incorporated into this VLT AutomationDrive?


The drive includes built-in motor protection against overcurrent and overtemperature. It also supports safety functions like safe torque off (STO). Always follow installation safety guidelines.


How is the DANFOSS FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX installed?


Installation involves mounting in a suitable enclosure and correctly wiring power, motor, and control signals. Proper grounding is essential. Follow the detailed wiring diagrams in the manual.


What is the typical efficiency of the FC-302P11KT5E20H2XGCXXXSXXXXAXBXCXXXXDX?


Efficiency is very high, especially at reduced speeds, leading to significant energy savings. Exact figures vary with load and speed. Danfoss drives are known for their energy performance.


What common fault codes should I be aware of for this drive?


Common codes include overcurrent (F001) and overtemperature (F004). These often indicate motor load or environmental issues. Consult the manual for specific troubleshooting steps.


How can this drive be integrated with IIoT solutions?


Integration is achieved through optional fieldbus communication modules that support standard industrial protocols. This enables remote monitoring and data acquisition for IIoT platforms.

Menu