The DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX 15kW IP55 500V Three Phase Automation Inverter is engineered for robust performance and precise control in demanding industrial environments. This advanced variable frequency drive (VFD) delivers exceptional energy efficiency, enhanced motor protection, and seamless integration into automated systems. Its core advantages lie in its superior power density, advanced thermal management, and comprehensive programmability, making it a preferred choice for applications requiring reliable and efficient motor speed control.
| Parameter | Specification |
| :------------------------ | :-------------------------------------------- |
| Model Number | FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX |
| Power Rating | 15 kW |
| Enclosure Class | IP55 |
| Input Voltage | 500V Three Phase |
| Control Type | Automation Inverter |
| Output Frequency | Up to 650 Hz |
| Overload Capacity | 150% for 60 seconds |
| Ambient Temperature | -20°C to +50°C (derating above 40°C) |
| Harmonic Distortion | Integrated DC choke for reduced harmonics |
| Communication Options | Serial (RS-485, RS-232), Fieldbus (optional) |
The DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX stands out with its advanced VVCplus® control, ensuring optimal motor performance and energy savings across a wide speed range. This technology minimizes energy consumption, directly translating to reduced operational costs. The inverter's robust design, including its IP55 enclosure, provides superior protection against dust and water ingress, guaranteeing reliable operation in challenging industrial settings. Its integrated safety functions, such as Safe Torque Off (STO), enhance operational safety and compliance with machinery directives. This combination of efficiency, durability, and safety positions the FC-302 inverter favorably in competitive markets where performance and reliability are paramount.
Key application scenarios for the DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX include pump and fan control, where precise speed adjustment significantly reduces energy usage. It is also widely employed in conveyor systems, mixers, extruders, and general machinery applications that demand accurate motor speed regulation and high torque at low speeds. Industries such as water and wastewater treatment, HVAC, food and beverage processing, and material handling benefit greatly from the inverter's energy-saving capabilities and its ability to optimize process efficiency. The 500V rating makes it suitable for applications requiring higher voltage supplies, common in large industrial facilities.
System integration of the DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX is streamlined due to its flexible communication options and standardized mounting. For optimal installation, ensure adequate ventilation around the drive to maintain operating temperatures within specified limits, especially when operating at higher ambient temperatures. Electrical connections must adhere to local electrical codes and the manufacturer's wiring diagrams. The integrated DC choke helps to reduce harmonic distortion, mitigating the need for external filters in many applications. Parameter programming can be performed via the front panel keypad or remotely using Danfoss's MCT 10 software, facilitating quick commissioning and adjustments to meet specific application requirements.
Operational safety and risk mitigation with the DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX are paramount. Always ensure the drive is properly grounded and that all safety interlocks, particularly the Safe Torque Off (STO) function, are correctly wired and tested before operation. Common troubleshooting involves checking for overload or overvoltage faults, which can often be resolved by verifying motor parameters and supply voltage stability. Reviewing the error logs via the keypad or software provides specific fault codes that can be cross-referenced with the user manual for detailed diagnostic information. Regular maintenance, including cleaning of ventilation openings, ensures consistent performance and longevity.
Scalability and long-term value are inherent in the DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX. Its modular design and compatibility with various fieldbus protocols, such as Profibus and DeviceNet, allow for seamless integration into existing SCADA and DCS systems. This enables advanced monitoring, diagnostics, and control capabilities, aligning with Industry 4.0 initiatives and the growing demand for Industrial Internet of Things (IIoT) solutions. The robust construction and Danfoss's reputation for reliability ensure a long operational life, minimizing the total cost of ownership through reduced maintenance and energy savings.
FAQs
What is the primary function of the DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX?
It is an automation inverter designed for variable speed control of three-phase motors. It offers precise speed regulation and torque control.
This VFD optimizes motor performance and energy consumption in various industrial applications. It aids in reducing operational costs and extending motor lifespan.
The inverter facilitates integration into automated systems, enabling sophisticated process control and monitoring for enhanced efficiency and productivity.
Can the DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX be used with single-phase motors?
No, this model is specifically designed for three-phase motors. It requires a three-phase power supply for operation.
Using it with a single-phase motor would result in malfunction and potential damage to the drive and motor. Always match the drive to the correct motor type.
Refer to Danfoss documentation for single-phase motor control solutions, which are typically different VFD models.
What is the IP55 rating significant for this inverter?
The IP55 rating signifies protection against dust ingress and water jets from any direction. This ensures durability in harsh industrial environments.
It means the drive can withstand challenging conditions like washdowns or dusty factory floors without compromising performance or safety.
This rating makes the FC-302 suitable for applications in food processing, outdoor installations, or areas with high levels of particulate matter.
How does the VVCplus® control benefit motor operation?
VVCplus® ensures optimal motor performance and significantly reduces energy consumption across various speeds. It provides precise torque control.
This advanced control method minimizes energy losses, leading to substantial cost savings on electricity bills and a smaller carbon footprint.
It also improves motor efficiency, allowing for smoother operation and preventing issues like overheating or inefficient running at partial loads.
What are the typical applications for a 15kW, 500V inverter?
Common uses include pumps, fans, conveyors, mixers, and extruders in heavy industrial settings. These applications benefit from precise speed and torque.
It is ideal for large-scale operations in sectors like water treatment, chemical processing, and manufacturing where high power and voltage are needed.
The 15kW power and 500V rating suit applications requiring robust motor control for demanding loads and extended duty cycles.
Does this inverter offer safety features like Safe Torque Off (STO)?
Yes, the DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX includes Safe Torque Off (STO) functionality. This is a crucial safety feature for machinery.
STO ensures that the motor cannot generate torque when the function is activated, preventing unexpected starts and enhancing personnel safety during maintenance.
Proper implementation and wiring of the STO function are essential for compliance with safety standards and to protect operators from hazards.
What communication protocols are supported by the FC-302 inverter?
This inverter supports serial communication (RS-485, RS-232) and offers optional fieldbus modules for protocols like Profibus and DeviceNet.
These options allow seamless integration into existing industrial automation networks and control systems, enabling remote monitoring and control.
The flexibility in communication protocols ensures compatibility with a wide range of PLCs and SCADA systems for enhanced process automation.
How can harmonic distortion be managed with this inverter?
The FC-302 features an integrated DC choke which inherently reduces harmonic distortion generated by the drive. This often eliminates the need for external filters.
Minimizing harmonics protects sensitive equipment on the same power network and improves overall power quality and system efficiency.
For applications with very strict harmonic distortion limits, additional filtering solutions can be implemented in conjunction with the inverter.
What is the recommended ambient operating temperature range?
The inverter is rated for ambient temperatures between -20°C and +50°C. Derating is required for operation above 40°C.
Operating within the specified temperature range, with adequate ventilation, is crucial for ensuring the longevity and reliable performance of the drive.
Proper ventilation design and thermal management are key considerations during installation to prevent overheating and premature component failure.
How do I program the DANFOSS FC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDX?
Programming can be done using the integrated keypad on the drive's front panel or via Danfoss's MCT 10 software tool. The software offers more advanced configuration options.
The MCT 10 software allows for easy parameter setup, backup and restore of configurations, as well as real-time monitoring and diagnostics of the drive's operation.
Users can also utilize fieldbus communication for remote programming and parameterization, facilitating integrated control strategies in complex automation systems.