INVT GD350-250G-6 Goodrive350 High Voltage Inverter 250kW Heavy Duty Performance 690V

stars
  • Availability:In Stock
  • Brand:INVT
  • Model:GD350-250G-6
  • HS: 8504409999
Availability:In Stock
$7713.60
zhongpingtech

The INVT GD350-250G-6 Goodrive350 High Voltage Inverter stands as a robust solution for demanding industrial applications, offering 250kW of heavy-duty performance at 690V. This advanced variable frequency drive (VFD) distinguishes itself through its exceptional power control, energy efficiency, and advanced protection features, making it a superior choice for critical motor control scenarios. Its core advantages lie in its ability to precisely manage motor speed and torque, leading to significant operational cost savings and enhanced process control. Key technical parameters highlight its capability, including an input voltage of 690V and a rated power of 250kW, suitable for the most challenging heavy-duty industrial operations.


Product Specifications


| Parameter             | Specification                                 |

| :-------------------- | :-------------------------------------------- |

| Model                 | INVT GD350-250G-6 Goodrive350                   |

| Rated Power           | 250 kW                                        |

| Input Voltage         | 690V                                          |

| Output Voltage        | 0-690V (adjustable)                           |

| Control Method        | Vector Control, V/f Control                   |

| Protection Features   | Overload, Over-voltage, Under-voltage, etc.   |

| Degree of Protection  | IP20 (standard)                               |

| Cooling Method        | Air Cooling                                   |

| Ambient Temperature   | -10°C to +40°C                                |


Core Features & Market Positioning


The INVT GD350-250G-6 Goodrive350 is engineered with advanced vector control algorithms, delivering precise and dynamic motor response, even under fluctuating load conditions. This inverter positions itself as a high-performance, reliable, and cost-effective solution in the high-voltage VFD market, competing with established global brands through its blend of sophisticated features and robust build quality. Its market differentiation is further solidified by its comprehensive protection mechanisms, safeguarding both the motor and the drive from potential electrical anomalies, thereby minimizing downtime and maintenance costs. The GD350 series is recognized for its adaptability and ease of integration into various industrial automation systems.


Key Application Scenarios


This heavy-duty inverter finds its optimal application in sectors requiring high power and precise motor control, such as large fan and pump systems in water treatment plants and HVAC applications. It is also extensively used in critical material handling operations, including conveyors and cranes in mining and logistics, where consistent torque and speed regulation are paramount for operational efficiency and safety. Furthermore, the INVT GD350-250G-6 is well-suited for driving compressors in the petrochemical industry and mills in the cement sector, environments characterized by continuous operation and significant mechanical loads.


Practical System Integration Guidance


Integrating the INVT GD350-250G-6 into an industrial setup requires careful attention to power wiring and control signal connections. The drive should be installed in a clean, well-ventilated environment, adhering to specified clearance distances to ensure adequate heat dissipation. Proper grounding is critical for electrical safety and noise reduction; the main power terminals (L1, L2, L3) should be connected to the 690V supply, while the motor leads are connected to T1, T2, T3. Control wiring, including digital inputs for start/stop, speed selection, and analog inputs for speed reference, should follow the terminal diagram provided in the user manual to ensure correct functionality and prevent feedback issues. Parameter configuration, accessible via the drive's keypad or PC software, is essential for optimizing performance, with key settings including motor data, acceleration/deceleration times, and limit functions tailored to the specific application.


Operation and Risk Mitigation


Safe operation of the INVT GD350-250G-6 mandates adherence to established safety protocols, including lockout/tagout procedures during maintenance and ensuring all personnel are adequately trained on VFD operation and hazards. Key risk mitigation strategies involve regular inspection of power connections for signs of wear or overheating, monitoring operating temperatures, and performing periodic diagnostic checks. Common fault codes, such as "Overload" (F01) or "Overvoltage" (F02), typically indicate issues with the load, power supply, or deceleration parameters, requiring prompt investigation. Addressing these issues involves verifying motor and load conditions, checking input voltage stability, and adjusting control parameters within the drive's protective limits.


Scalability & Long-Term Value


The INVT GD350-250G-6 Goodrive350 offers considerable scalability, allowing for flexible integration into expanding industrial systems. Its compatibility with standard industrial communication protocols enables seamless connection to SCADA systems and PLCs, facilitating centralized control and monitoring. For industries embracing Industry 4.0, this inverter supports integration with IIoT platforms, providing valuable operational data for predictive maintenance and performance optimization. This forward-looking design ensures that the GD350 series remains a relevant and valuable asset for long-term operational efficiency and technological advancement.


FAQs


What are the primary benefits of using the INVT GD350-250G-6?

The INVT GD350-250G-6 offers substantial energy savings by precisely controlling motor speed. It also enhances process control and reduces mechanical stress on equipment.

This high-voltage inverter provides superior motor protection against electrical faults, minimizing downtime and repair costs. Its robust design ensures reliability in heavy-duty industrial environments.

The drive's advanced features, like vector control, deliver precise torque and speed performance, crucial for demanding applications. It supports efficient operation and extended equipment lifespan.


How does the INVT GD350-250G-6 handle heavy-duty loads?

Its 250kW power rating and advanced vector control are specifically designed for high-torque, continuous operation. This ensures stable performance even under severe load fluctuations.

The inverter incorporates advanced thermal management systems to dissipate heat effectively during prolonged periods of high demand. This prevents overheating and ensures operational integrity.

Built with robust components and rigorous testing, the GD350-250G-6 meets the demanding requirements of heavy-duty industrial applications, offering sustained reliability.


What are the key technical specifications for the GD350-250G-6?

This unit operates with a 690V input voltage and delivers up to 250kW of power. It is designed for heavy-duty industrial performance.

It supports versatile control methods, including advanced vector control and V/f control, offering flexibility for various motor applications. The output voltage is adjustable from 0 to 690V.

Comprehensive protection features are integrated, such as overload, overvoltage, and undervoltage protection, ensuring operational safety and equipment longevity.


Can the INVT GD350-250G-6 be integrated with existing industrial systems?

Yes, its design supports integration with various automation systems through standard communication protocols. This allows for seamless monitoring and control.

The drive offers flexible input and output terminals for easy connection to PLCs, sensors, and actuators. Parameterization tools facilitate customization for specific system requirements.

Its compatibility with common industrial networks ensures it can be effectively incorporated into new or upgraded automation architectures.


What are common applications for this high-voltage inverter?

It is ideal for large fans and pumps in water treatment, oil, and gas industries where precise flow control is needed. This ensures efficient resource management.

The INVT GD350-250G-6 is used in heavy machinery like extruders, compressors, and crushers in manufacturing, mining, and cement production. It provides the necessary power and control.

It is also applied in material handling, such as conveyors and elevators, and in critical processes within the petrochemical sector. Its reliability is key in these continuous operations.


What safety precautions should be taken when operating the INVT GD350-250G-6?

Always ensure proper grounding of the inverter and motor to prevent electrical hazards and reduce electromagnetic interference. Follow safe isolation procedures during maintenance.

Personnel operating or maintaining the GD350-250G-6 must be adequately trained on VFD safety and emergency procedures. Never bypass safety interlocks or protective functions.

Operate the inverter within its specified environmental limits for temperature and humidity to ensure safe and reliable performance. Regularly inspect power cables for damage.


How does the INVT GD350-250G-6 contribute to energy efficiency?

By adjusting motor speed to match the actual load requirement, the drive significantly reduces energy consumption compared to fixed-speed operation. This leads to cost savings.

The advanced control algorithms optimize motor performance, minimizing energy losses and improving power factor. This maximizes the efficiency of the electrical system.

Its ability to operate at lower speeds for reduced demand scenarios further contributes to substantial energy savings over the equipment's lifecycle.


What are the typical fault codes and their meanings for this inverter?

Common fault codes include F01 for Overload, indicating the motor is drawing too much current, possibly due to mechanical issues or excessive load. Proper investigation of the driven load is essential.

Other frequent codes might be F02 for Overvoltage, suggesting issues with the input power supply or regenerative energy, and F03 for Undervoltage, indicating a low input supply voltage. Checking the power source is crucial.

Understanding these codes helps in quickly diagnosing problems, whether they relate to the motor, the power supply, or the drive's internal settings, enabling prompt resolution.


How is the INVT GD350-250G-6 installed and commissioned?

Installation involves mounting the unit in a suitable environment, ensuring adequate ventilation and clearances, and correctly wiring the main power and motor connections. Follow the manufacturer's installation manual precisely.

Commissioning requires careful parameter setting, including motor identification, speed reference configuration, and adjustment of protection limits to match the application's specific requirements. Initial test runs at reduced speed are recommended.

After initial setup, perform comprehensive testing under various load conditions to verify performance, safety functions, and communication with control systems. Document all settings and test results.


What is the long-term value proposition of the GD350-250G-6?

Its robust construction and high-quality components ensure a long operational lifespan with minimal maintenance requirements. This reduces total cost of ownership.

The inverter's ability to integrate with Industry 4.0 solutions allows for future-proofing and enhanced data analytics for predictive maintenance. This supports continuous operational improvement.

As technology advances, the GD350-250G-6's compatibility with updated systems and its inherent energy-saving capabilities maintain its value by contributing to sustained efficiency and productivity.

Menu