Siemens 5SV3324-4 High Current RCBO 2P 40A 30mA

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SV3324-4
  • HS: 8536300000
Availability:In Stock
$554.13
zhongpingtech

The Siemens 5SV3324-4 is a robust 2-pole, 40A, 30mA Residual Current Circuit Breaker with Overcurrent Protection (RCBO), engineered for superior electrical safety and reliability in demanding industrial and commercial environments. This advanced device integrates the functions of a residual current device (RCD) and a miniature circuit breaker (MCB) into a single, compact unit, offering comprehensive protection against overload, short circuits, and dangerous earth leakage currents. Its high breaking capacity and sensitive tripping characteristics make it an indispensable component for safeguarding personnel and equipment.


Product Specifications


| Feature                       | Specification                               |

| :---------------------------- | :------------------------------------------ |

| Product Type                  | RCBO (Residual Current Circuit Breaker with Overcurrent Protection) |

| Pole Configuration            | 2-Pole                                      |

| Rated Current (In)            | 40 A                                        |

| Rated Residual Current (IΔn)  | 30 mA                                       |

| Rated Voltage (Ue)            | 400 V AC                                    |

| Rated Breaking Capacity (Icn) | 6 kA                                        |

| Tripping Characteristic       | Type B                                      |

| Frequency                     | 50/60 Hz                                    |

| Terminal Type                 | Screw Terminals                             |

| Mounting Type                 | DIN Rail                                    |

| Protection Class              | IP20 (enclosure), IP40 (with cover)         |

| Operating Temperature         | -25°C to +45°C                              |

| Standards                     | IEC/EN 61009-1, IEC/EN 60898-1, IEC/EN 61009-2-1 |


Core Features & Market Positioning


The Siemens 5SV3324-4 RCBO stands out in the market due to its dual-functionality, significantly reducing panel space and installation complexity compared to separate RCD and MCB installations. Its Type B tripping characteristic provides reliable protection against both sinusoidal alternating fault currents and pulsating direct fault currents, a crucial advantage in applications involving sensitive electronic equipment or variable speed drives. Siemens' reputation for manufacturing excellence ensures exceptional durability and consistent performance, positioning the 5SV3324-4 as a premium, dependable solution for critical power distribution circuits. The 6 kA breaking capacity further enhances its utility in areas with potential for high fault currents.


Key Application Scenarios


This RCBO is ideally suited for safeguarding circuits in commercial buildings, industrial facilities, and demanding residential applications where enhanced protection against electric shock and fire hazards is paramount. Specific use cases include protecting circuits feeding machinery, distribution boards in hazardous locations (where permitted by local regulations), and areas with a higher risk of earth faults, such as workshops and server rooms. It is a vital component for ensuring compliance with stringent electrical safety standards and protecting sensitive loads from overcurrents and residual currents.


Practical System Integration Guidance


Integrating the Siemens 5SV3324-4 into existing electrical systems is straightforward due to its standard 2-module width and DIN rail mounting compatibility. Ensure that the incoming power supply conductors are connected to the upper terminals and the outgoing load conductors to the lower terminals, observing correct polarity. The neutral conductor must be connected to the designated neutral terminal. Proper termination requires using appropriate torque settings as specified in the installation manual to prevent overheating and ensure a secure connection. Grounding of the unit itself is typically achieved through the DIN rail.


Operation and Risk Mitigation


The 5SV3324-4 operates automatically, tripping and disconnecting the circuit when an overload, short circuit, or a residual current exceeding 30mA is detected. The test button (usually a "T" or "TEST" marking) should be pressed periodically (monthly is recommended) to verify the tripping mechanism's functionality. If the RCBO trips, identify and rectify the fault before resetting the switch. Persistent tripping indicates a persistent fault requiring professional diagnosis. Always ensure the power is isolated before performing any maintenance or inspection of the RCBO or connected circuits.


Scalability & Long-Term Value


While the 5SV3324-4 is a fixed-rated device, its integration into Siemens' broader electrical distribution portfolio offers excellent scalability. It is compatible with other Siemens circuit protection devices and busbar systems, allowing for straightforward expansion of distribution boards. Its robust construction and adherence to international standards guarantee a long service life, minimizing the need for premature replacements. For future digital integration, consider coupling this RCBO with Siemens' smart metering and monitoring solutions to enable remote diagnostics and energy management capabilities within an IIoT framework.


Frequently Asked Questions (FAQs)


What is the primary function of the Siemens 5SV3324-4 RCBO?

The Siemens 5SV3324-4 RCBO primarily functions as a combined protective device. It safeguards electrical circuits against overcurrents, short circuits, and dangerous earth leakage currents. This dual protection is critical for preventing electrical fires and protecting individuals from electric shock.


This RCBO offers robust circuit protection in a single, compact unit. It replaces the need for separate MCBs and RCDs, simplifying panel layouts and installation. The 40A rating is suitable for moderate to high load circuits.


The 30mA residual current sensitivity ensures prompt disconnection, providing essential protection against direct and indirect contact with live conductors. Its integration offers a high level of safety for both personnel and connected equipment.


Can the Siemens 5SV3324-4 be used in residential applications?

Yes, the Siemens 5SV3324-4 is highly suitable for residential applications, especially in areas requiring enhanced safety. It provides vital protection against earth faults, a common cause of electrical fires and shocks in homes. Its installation ensures compliance with modern electrical safety standards.


This RCBO is particularly recommended for circuits supplying high-risk areas within a residence. Examples include kitchens, bathrooms, garages, and circuits powering outdoor equipment. The 30mA tripping current offers crucial personal protection.


By integrating overcurrent and residual current protection, it simplifies main distribution boards and sub-panels in homes. This makes installation more efficient and cost-effective while maximizing safety.


What does the "Type B" tripping characteristic signify for this RCBO?

The "Type B" tripping characteristic indicates how the RCBO responds to different types of fault currents. It is designed to trip on sinusoidal AC fault currents, which are standard. Crucially, it also responds to pulsating DC fault currents.


This dual response capability makes the 5SV3324-4 ideal for modern installations. It offers superior protection when used with equipment that can generate DC fault currents, such as variable frequency drives (VFDs) or certain types of power supplies.


Without this feature, a standard Type AC or Type A RCD might not trip correctly in the presence of DC components, potentially leading to a dangerous situation. Type B offers a more comprehensive safety net.


How does the 40A current rating impact its application?

The 40A rating signifies the maximum continuous current the RCBO can handle without tripping due to overload. This makes it suitable for circuits with significant power demands, commonly found in industrial and commercial settings. It can protect multiple circuits or a single high-power appliance.


This rating ensures that circuits supplying machinery, large HVAC units, or distribution feeders are adequately protected. It prevents thermal overloads that could damage equipment or wiring, thereby extending their operational life and preventing costly downtime.


When selecting an RCBO, it's vital to match the current rating to the expected load and the circuit's wire gauge. The 40A rating offers a good balance for many heavy-duty applications where smaller ratings would be insufficient.


What is the significance of the 30mA residual current trip level?

A 30mA residual current trip level is considered a safety threshold for personal protection against electric shock. It means the device will disconnect the circuit when it detects a leakage current of 30 milliamperes or more to earth. This level is generally considered safe for human contact.


This sensitivity is crucial for preventing severe injury or fatality from electric shock. When a person accidentally touches a live conductor, a leakage path to earth is created, and the RCBO will trip very rapidly, often before significant harm can occur.


This trip level is a standard requirement in many electrical codes and regulations for socket outlets and circuits where direct contact with live parts is a possibility. It significantly enhances safety in both domestic and industrial environments.


What does a 6kA breaking capacity mean for the 5SV3324-4?

A 6kA breaking capacity refers to the maximum fault current the RCBO can safely interrupt without sustaining damage. This rating is critical in electrical installations where high prospective fault currents are possible, such as near the main power source or in industrial facilities. It ensures the device can safely clear a short circuit.


This specification indicates the RCBO's robustness and its ability to safely disconnect under severe fault conditions. It is designed to withstand the immense energy released during a short circuit event, preventing further damage to the electrical system or creating a fire hazard.


When selecting protective devices, it's essential to ensure their breaking capacity is greater than or equal to the prospective fault current at their point of installation. The 6kA rating provides a reliable level of protection for many standard applications.


How do I test the functionality of the Siemens 5SV3324-4?

The Siemens 5SV3324-4 is equipped with a test button, typically marked with a "T" or "TEST" symbol. To test its functionality, press this button while the circuit is energized. This simulates a residual current fault and should cause the RCBO to trip, disconnecting power to the circuit.


Regular testing, typically recommended monthly, is crucial to ensure the protective mechanism remains operational. If the RCBO does not trip when the test button is pressed, it indicates a malfunction and the device must be replaced immediately by a qualified electrician.


Always remember to reset the RCBO after a successful test. If the RCBO trips repeatedly upon resetting, it signifies an underlying fault in the circuit that requires professional diagnosis and repair before re-energizing.


Is the Siemens 5SV3324-4 compatible with other brands' components?

While the 5SV3324-4 adheres to international standards (IEC/EN 61009-1), ensuring a degree of interoperability, it is highly recommended to use components from the same manufacturer for optimal system integrity and performance. Siemens designs its products to work seamlessly within their ecosystem.


Using components from different manufacturers might lead to compatibility issues, reduced performance, or even safety compromises. Electrical codes often recommend or require using a consistent brand for critical protective devices within an installation.


For critical applications and to guarantee full warranty and compliance, it is best practice to integrate the 5SV3324-4 with other Siemens protection and distribution components. This ensures reliable operation and simplifies troubleshooting.


What is the typical lifespan of a Siemens 5SV3324-4 RCBO?

The typical lifespan of a Siemens 5SV3324-4 RCBO is generally long, often measured in decades under normal operating conditions. Siemens products are known for their durability and high quality, designed for sustained performance in demanding environments. However, lifespan can be influenced by factors like the frequency of tripping, environmental conditions, and installation quality.


Factors such as frequent fault occurrences, exposure to extreme temperatures, humidity, or corrosive environments can reduce the operational life of any electrical component, including RCBOs. Regular testing and maintenance, as outlined in the manufacturer's guidelines, are essential for ensuring continued reliable operation.


It is advisable to conduct periodic inspections and consider replacement if the device shows signs of wear, damage, or if it has experienced a significant number of trips or a major fault event, even if it appears to be functioning correctly.


Where can I find the installation manual or further technical documentation for this RCBO?

The most reliable source for the official installation manual and comprehensive technical documentation for the Siemens 5SV3324-4 RCBO is directly from the Siemens official website or through authorized Siemens distributors. These documents contain detailed information on specifications, installation, operation, and troubleshooting.


You can typically access product datasheets, technical guides, and installation instructions by searching for the product number (5SV3324-4) on the Siemens Industry Online Support (SIOS) portal or the relevant regional Siemens website. These resources are usually available for download in PDF format.


Always ensure you are accessing the most current version of the documentation to guarantee adherence to the latest safety standards and installation best practices. If you encounter difficulties, contacting Siemens technical support or your local distributor is recommended.