Siemens 5SV3646-6KK01 Residual Current MCB Module 4P 63A 300mA

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SV3646-6KK01
  • HS: 8536300000
Availability:In Stock
$239.98
zhongpingtech

The Siemens 5SV3646-6KK01 Residual Current Miniature Circuit Breaker (RCBO) Module is a robust four-pole device designed for comprehensive electrical protection. It offers a 63A rated current and a 300mA residual current sensitivity, ensuring superior safety against electrical shock and fire hazards. This advanced module is engineered for reliable performance in demanding industrial environments, providing critical overcurrent and earth leakage protection in a single, compact unit. Its key advantages lie in its space-saving design, enhanced safety features, and Siemens' reputation for quality and durability, making it a preferred choice for safeguarding electrical installations.


Product Specifications


| Feature                  | Specification                                    |

| :----------------------- | :----------------------------------------------- |

| Product Type             | Residual Current MCB Module                      |

| Pole Configuration       | 4-Pole (4P)                                      |

| Rated Current (In)       | 63 A                                             |

| Rated Residual Current   | 300 mA                                           |

| Breaking Capacity (Icn)  | 10 kA                                            |

| Voltage Rating (Ue)      | 400 V AC                                         |

| Frequency                | 50/60 Hz                                         |

| Tripping Characteristic  | Type A                                           |

| Mounting Type            | DIN Rail                                         |

| Protection Class         | IP20 (enclosure), IP40 (terminal)                |

| Operating Temperature    | -25°C to +45°C                                   |

| Standards                | IEC/EN 61008-1, IEC/EN 60947-2, IEC/EN 61009-1 |


Core Features & Market Positioning


The Siemens 5SV3646-6KK01 stands out in the protective devices market due to its integrated design, combining Miniature Circuit Breaker (MCB) and Residual Current Device (RCD) functionalities. This integration significantly reduces installation space and complexity compared to separate units. The Type A tripping characteristic ensures protection against both sinusoidal alternating currents and pulsating direct currents, offering a broader safety margin. Siemens' extensive experience in industrial automation and electrical engineering underpins the reliability and performance of this module. It is positioned as a high-quality, dependable solution for critical infrastructure protection where safety and operational continuity are paramount. Its robust construction and adherence to stringent international standards (IEC/EN) further solidify its standing as a premium component for industrial electrical systems.


Key Application Scenarios


This 4-pole 63A 300mA RCBO module is ideally suited for a wide array of industrial applications. It is a crucial component in power distribution systems for manufacturing plants, where it protects machinery and personnel from earth faults and overloads. In commercial buildings, it provides essential safety for lighting circuits and power outlets. Data centers benefit from its reliable protection to ensure uninterrupted operation and safeguard sensitive equipment. Furthermore, it finds application in the energy sector for protecting generators and transformers, as well as in water treatment facilities where the presence of moisture necessitates enhanced electrical safety measures. Its suitability for TN and TT earthing systems makes it versatile across various network configurations.


Practical System Integration Guidance


Integrating the Siemens 5SV3646-6KK01 module into existing electrical panels is straightforward due to its standard DIN rail mounting compatibility. For a 4-pole configuration, it is essential to correctly connect all four terminals: three for the phase conductors (L1, L2, L3) and one for the neutral conductor (N). The incoming power supply should be connected to the top terminals, and the outgoing load connections to the bottom terminals. Proper grounding of the system is critical for the effective operation of the residual current function. Ensure that the neutral conductor is not switched or fused within the protected circuit, as this can lead to malfunctioning of the RCBO. When wiring, use conductors of appropriate gauge to handle the 63A current rating. It is also important to maintain adequate clearance around the module for ventilation and to prevent overheating.


Operation and Risk Mitigation


The primary function of the Siemens 5SV3646-6KK01 is to provide protection against electric shock by quickly disconnecting the power supply when an imbalance current (leakage current) is detected, typically caused by a fault to earth. The 300mA sensitivity is designed to protect against fire hazards and provides a level of protection against direct contact in industrial settings. It also protects against overcurrents (overloads and short circuits) through its integrated MCB function, preventing damage to equipment and wiring. In the event of a fault, the module will trip, indicated by the position of the toggle switch. To reset, ensure the fault condition has been cleared, then firmly push the toggle switch upwards. Common troubleshooting involves checking for earth faults in connected equipment or wiring, ensuring correct wiring of the neutral conductor, and verifying that the module is not subjected to currents exceeding its rating or environmental limits.


Scalability & Long-Term Value


The Siemens 5SV3646-6KK01 RCBO module offers significant long-term value through its compatibility with Siemens' broader Sentron protection device portfolio. This ensures seamless integration into larger electrical distribution systems and facilitates future expansions or upgrades. Its robust design and high-quality construction, characteristic of Siemens industrial products, guarantee a long operational lifespan with minimal maintenance requirements. While this specific module provides advanced protection, its placement within a well-designed system allows for strategic scalability. For enhanced monitoring and integration into IIoT or digital solutions, it can be complemented by other Siemens components, such as communication-enabled circuit breakers or gateway devices, enabling remote diagnostics and predictive maintenance capabilities, thereby future-proofing the electrical infrastructure.


Frequently Asked Questions


What is the primary function of the Siemens 5SV3646-6KK01?

This module primarily protects electrical installations against overcurrents and earth leakage faults. It combines the functions of a Miniature Circuit Breaker (MCB) and a Residual Current Device (RCD) in one unit. This dual protection is vital for preventing electrical fires and safeguarding personnel from electric shock.


The 63A rating indicates its capacity to handle significant current loads common in industrial settings. Its 300mA residual current sensitivity is optimized for fire protection and protection against indirect contact. Therefore, it ensures a high level of safety in various applications.


The integrated design saves space in electrical panels and simplifies installation compared to using separate MCB and RCD devices. This makes it an efficient and cost-effective solution for comprehensive electrical safety.


How do I correctly install the Siemens 5SV3646-6KK01 RCBO module?

Ensure the main power supply is switched off before commencing installation work. Mount the module securely onto a standard 35mm DIN rail within the electrical enclosure. Connect the incoming phase and neutral conductors to the upper terminals of the module.


Connect the outgoing phase and neutral conductors for the protected circuit to the lower terminals. It is crucial that the neutral conductor is connected correctly and is not switched by the device itself. Ensure all connections are tight and follow local electrical codes for wiring practices.


Verify that the module is suitable for the earthing system (TN or TT) and that the correct number of poles are utilized for the intended circuit configuration. Double-check all wiring before restoring power to prevent damage or hazardous situations.


What type of faults does the Siemens 5SV3646-6KK01 protect against?

This RCBO module provides protection against overload currents, which occur when a circuit draws more current than it is designed for over an extended period. It also protects against short-circuit currents, which are sudden, high-magnitude current flows caused by faults like damaged insulation.


Additionally, it offers protection against residual currents, commonly known as earth leakage. This occurs when current flows through an unintended path, such as through a person or faulty insulation to the ground. The 300mA sensitivity is particularly effective for preventing fires.


The Type A tripping characteristic means it detects both sinusoidal alternating residual currents and pulsating direct residual currents, providing a more comprehensive safety coverage compared to Type AC devices. This makes it suitable for circuits with electronic equipment that may generate such currents.

Menu