Siemens 3VA2780-1AB02-4HA7 Molded Case Air Circuit Breaker 800A 3P 55kA

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3VA2780-1AB02-4HA7
  • HS: 85362020
Availability:In Stock
$2747.67
zhongpingtech

The Siemens 3VA2780-1AB02-4HA7 is a high-performance molded case air circuit breaker designed for robust electrical protection. This 3-pole, 800A, 55kA breaker offers superior safety, reliability, and advanced features for critical industrial applications. Its key advantages include exceptional breaking capacity, advanced tripping technology, and a compact design for efficient space utilization.


| Parameter                      | Value                               |

| :----------------------------- | :---------------------------------- |

| Product Type                   | Molded Case Air Circuit Breaker     |

| Siemens Model Number           | 3VA2780-1AB02-4HA7                  |

| Rated Current (In)             | 800A                                |

| Number of Poles                | 3                                   |

| Breaking Capacity (Icu)        | 55kA at 415V                        |

| Frame Size                     | 3VA27                             |

| Mounting Type                  | Fixed                               |

| Release Type                   | Electronic trip unit                |

| Undervoltage Release           | Yes                                 |

| Shunt Trip                     | Yes                                 |

| Auxiliary Contacts             | Integrated                          |

| Standards                      | IEC 60947-2                         |

| Protection Class               | IP20 (enclosure), IP40 (front)      |

| Operating Temperature Range    | -25 to +70 °C                       |

| Dimensions (W x H x D)         | 135 x 266 x 155 mm                  |

| Color                          | Grey                                |


Core Features & Market Positioning


The Siemens 3VA2780-1AB02-4HA7 distinguishes itself in the market through its advanced electronic trip unit, offering precise and adjustable protection settings for overcurrent, short-circuit, and earth-fault conditions. This intelligent protection allows for tailored system configurations, minimizing nuisance tripping while ensuring robust safety. Its high breaking capacity of 55kA at 415V makes it suitable for demanding industrial environments where fault currents can be substantial, providing a critical layer of safety and equipment protection. The breaker's integration capabilities with modern digital power management systems, including communication modules for remote monitoring and control, position it as a forward-thinking solution for smart grids and Industry 4.0 initiatives. Its robust construction and adherence to stringent international standards like IEC 60947-2 underscore its reliability and long service life, making it a preferred choice for engineers prioritizing operational continuity and safety.


Key Application Scenarios


This circuit breaker is ideally suited for protecting main feeders, distribution circuits, and large motor loads in industrial facilities such as manufacturing plants, chemical processing units, and data centers. Its high current rating of 800A and substantial breaking capacity make it a reliable choice for power distribution panels and switchgear assemblies in medium to high-voltage substations. The Siemens 3VA2780-1AB02-4HA7 is also frequently specified for applications requiring precise overcurrent coordination to selectively isolate faults without disrupting adjacent circuits, a critical requirement in complex electrical networks. Furthermore, its compatibility with various auxiliary and accessory components facilitates its integration into custom-engineered electrical protection schemes across diverse industrial sectors.


Practical System Integration Guidance


Integrating the Siemens 3VA2780-1AB02-4HA7 involves careful consideration of its fixed mounting type and terminal connections. For installation, ensure adequate clearance and ventilation as per manufacturer guidelines to maintain optimal operating temperatures, especially given its 800A rating. The breaker is typically wired using appropriately sized copper or aluminum conductors, secured firmly to the terminal blocks to prevent high-resistance connections that could lead to overheating. Commissioning involves setting the electronic trip unit's protection parameters—such as In, Ir, Im, and Ig settings—using the integrated keypad or optional communication interfaces, based on the protected circuit's load characteristics and desired selectivity with upstream and downstream protective devices. It is crucial to perform insulation resistance tests and operational checks to verify correct installation and functionality before energizing the circuit.


Operation and Risk Mitigation


Safe operation of the Siemens 3VA2780-1AB02-4HA7 hinges on understanding its trip unit's functionalities and potential fault conditions. Regular visual inspections for signs of wear, damage, or environmental contamination are essential for preventive maintenance. The electronic trip unit provides clear indications for fault types (e.g., overload, short circuit, ground fault), aiding in rapid troubleshooting and minimizing downtime. In case of unexpected tripping, consult the detailed manual for specific error codes and recommended actions. Risk mitigation also involves ensuring proper lockout/tagout procedures are followed during maintenance, and that personnel are adequately trained on the breaker's operation and safety features, including the functions of the integrated undervoltage and shunt trip releases.


Scalability & Long-Term Value


The Siemens 3VA2780-1AB02-4HA7 offers significant long-term value through its inherent design for adaptability and integration within evolving electrical infrastructure. Its modular design, particularly the ability to add communication modules and accessory components, allows for future upgrades to advanced monitoring, control, and diagnostics capabilities, aligning with Industry 4.0 principles. Compatibility with Siemens' broader power distribution portfolio ensures seamless integration into existing or planned Siemens systems, facilitating a unified and intelligent power management solution. This scalability reduces the need for wholesale system replacements as operational demands or technological advancements occur, providing a cost-effective and future-proof investment for industrial facilities.


Frequently Asked Questions


What is the breaking capacity of the Siemens 3VA2780-1AB02-4HA7?

The Siemens 3VA2780-1AB02-4HA7 features a robust breaking capacity of 55kA at 415V. This high rating is critical for safely interrupting fault currents in industrial power systems. It ensures protection against severe short-circuit events.


This specification is vital for applications where high fault levels are anticipated. It allows for reliable protection of downstream equipment and personnel. Compliance with IEC 60947-2 standards is met by this capacity.


The substantial 55kA capability signifies the breaker's ability to withstand and interrupt extremely high fault currents without sustaining damage. This ensures operational continuity and safety in demanding electrical environments.


What type of trip unit does the 3VA2780-1AB02-4HA7 use?

This Siemens circuit breaker utilizes an advanced electronic trip unit. This unit offers precise and adjustable protection settings for various fault conditions. It allows for sophisticated overcurrent and earth-fault protection.


The electronic trip unit enables enhanced selectivity and coordination within the electrical system. Settings for long-time, short-time, and instantaneous trips can be configured. It also supports communication capabilities for remote monitoring and diagnostics.


Benefits of the electronic trip unit include improved protection accuracy and reduced nuisance tripping compared to thermal-magnetic devices. This leads to greater system reliability and operational efficiency.


What are the main applications for the Siemens 3VA2780-1AB02-4HA7?

The 3VA2780-1AB02-4HA7 is primarily used in industrial power distribution. Key applications include main feeders, distribution boards, and protecting large electrical loads. It is suitable for manufacturing plants and chemical facilities.


Its 800A rating and 55kA breaking capacity are ideal for substations and switchgear assemblies. The breaker ensures reliable protection where fault currents are high. It also supports precise overcurrent coordination.


This circuit breaker is also deployed in data centers and other critical infrastructure. Its robust design and advanced features provide essential safety and operational continuity.


Can this circuit breaker be used in harsh industrial environments?

Yes, the Siemens 3VA2780-1AB02-4HA7 is designed for demanding industrial conditions. Its robust construction ensures reliability and longevity. The breaker offers an operating temperature range from -25 to +70 °C.


The molded case construction provides inherent durability against physical impacts and environmental factors. It meets relevant international standards for industrial electrical equipment, ensuring its suitability for challenging settings.


While offering robust protection, proper installation and maintenance are still recommended to maximize its performance in harsh environments. This includes ensuring adequate ventilation and protection against excessive dust or moisture.


How do I set the protection parameters on the 3VA2780-1AB02-4HA7?

Protection parameters are set via the electronic trip unit's integrated keypad and display. Users can configure settings for long-time, short-time, and instantaneous trip functions. Earth-fault protection (Ig) can also be adjusted.


Alternatively, parameters can be set using optional communication modules and connected software. This allows for remote configuration and management, especially in complex systems. Refer to the product manual for specific setting ranges and procedures.


Accurate parameter setting is crucial for effective circuit protection and selectivity. It requires understanding the electrical system's load characteristics and coordination requirements with other protective devices.


What are the dimensions of the Siemens 3VA2780-1AB02-4HA7?

The Siemens 3VA2780-1AB02-4HA7 has compact dimensions for efficient space utilization. Its dimensions are 135mm in width, 266mm in height, and 155mm in depth. This compact design aids in panel building.


These dimensions facilitate its installation in standard electrical enclosures and switchgear. The compact frame size (3VA27) is a key advantage for space-constrained applications. It allows for higher power density.


The specific measurements ensure compatibility with various mounting systems and panel layouts. Always verify clearances and mounting requirements as per installation guidelines.


Does this breaker support communication for remote monitoring?

Yes, the 3VA2780-1AB02-4HA7 supports communication for remote monitoring. It can be equipped with optional communication modules. These modules enable integration into digital power management systems.


Through communication interfaces like Modbus or PROFIBUS, real-time data can be accessed. This includes operational status, fault information, and energy measurements. Remote control functions may also be available.


This capability is essential for modern smart grids and Industry 4.0 applications. It allows for proactive maintenance, performance optimization, and centralized control of electrical assets.


What standards does the Siemens 3VA2780-1AB02-4HA7 comply with?

The Siemens 3VA2780-1AB02-4HA7 complies with the IEC 60947-2 standard. This is the international standard for low-voltage switchgear and controlgear, specifically for circuit-breakers. It ensures high levels of safety and performance.


Compliance with IEC 60947-2 signifies that the breaker has undergone rigorous testing for its electrical and mechanical characteristics. This includes tests for breaking capacity, insulation, and operational endurance.


Adherence to this standard ensures the breaker's reliability and suitability for use in global electrical installations. It provides assurance to engineers and end-users regarding its safety and functional integrity.


What is the rated current and voltage for this breaker?

The rated current (In) for the Siemens 3VA2780-1AB02-4HA7 is 800A. This indicates the maximum continuous current the breaker can safely carry under normal operating conditions. It is a 3-pole breaker.


While the rated current is 800A, the specific operating voltage at which the 55kA breaking capacity is rated is typically 415V. It's important to match the breaker's voltage rating to the system voltage.


This breaker is designed for use in low-voltage industrial power systems where high current carrying capacity and fault interruption capabilities are required. Always consult the detailed specifications for precise voltage ratings.


What types of releases are integrated into this circuit breaker?

The Siemens 3VA2780-1AB02-4HA7 features an electronic trip unit. This advanced unit provides comprehensive protection against overloads, short circuits, and ground faults. It allows for adjustable settings for these protection parameters.


Additionally, the breaker is equipped with integrated undervoltage and shunt trip releases. These auxiliary releases are essential for remote operation and safety interlocks. The undervoltage release trips the breaker when system voltage drops below a set threshold.


The shunt trip release allows the breaker to be tripped remotely by an external signal, which is crucial for emergency stop systems or remote switching operations. These integrated functions enhance the breaker's utility and safety.