Siemens 3VA1220-6EE32-0AA0 High Breaking Capacity Molded Case Circuit Breaker 250A 3P 36kA

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3VA1225-4EE32-0AA0
  • HS: 85362020
Availability:In Stock
$297.57
zhongpingtech

The Siemens 3VA1220-6EE32-0AA0 stands as a robust and reliable solution for modern electrical distribution, offering a high breaking capacity of 36kA, a 250A rating, and three poles within its molded case circuit breaker design. This breaker is engineered for superior protection and operational efficiency in demanding industrial environments. Key advantages include its compact size, advanced trip unit technology, and high fault current handling capability, ensuring maximum safety and uptime for critical power systems.


| Parameter                      | Specification                               |

| :----------------------------- | :------------------------------------------ |

| Product Type                   | Molded Case Circuit Breaker (MCCB)          |

| Siemens Model Number           | 3VA1220-6EE32-0AA0                          |

| Rated Current (In)             | 250 A                                       |

| Number of Poles                | 3P (3-pole)                                 |

| Breaking Capacity (Icu)        | 36 kA                                       |

| Voltage Rating (AC)            | Up to 690 V                                 |

| Trip Unit Type                 | Electronic, ETU320 (overload and short-circuit) |

| Connection Type                | Front, rear, plug-in, and panel mounting    |

| Mounting Type                  | Fixed                                       |

| Standards Compliance           | IEC 60947-2                                 |

| Ambient Temperature Range      | -40 °C to +70 °C                            |


The Siemens 3VA1220-6EE32-0AA0 differentiates itself through its advanced electronic trip unit (ETU320), which provides precise and adjustable protection against overloads and short circuits. This technology minimizes nuisance tripping while ensuring swift disconnection during fault events, safeguarding downstream equipment and personnel. Its high breaking capacity of 36kA is critical for applications where significant fault currents are anticipated, offering a superior level of safety compared to lower-rated breakers. The compact form factor also facilitates space-saving installations in control panels and switchgear, a significant advantage in modern industrial settings where space is often at a premium. This makes it a compelling choice for system designers prioritizing both performance and physical footprint.


This high-breaking capacity molded case circuit breaker finds its primary applications in industrial power distribution systems, motor control centers (MCCs), and main incoming feeders. It is ideal for protecting equipment in manufacturing plants, data centers, and commercial buildings where reliable power and robust fault protection are paramount. The 250A rating and 3-pole configuration make it suitable for a wide range of load types, including large motors, transformers, and distribution feeders, ensuring operational continuity and preventing costly downtime. Its versatility allows for seamless integration into both new installations and retrofits.


Integration of the Siemens 3VA1220-6EE32-0AA0 into existing electrical systems is straightforward due to its flexible connection options, supporting front, rear, plug-in, and panel mounting. The circuit breaker is designed for fixed mounting and accommodates various wiring configurations. For systems requiring remote monitoring or advanced control, optional communication modules can be integrated, allowing for data exchange with SCADA systems or building management platforms. Ensuring proper torque settings on terminals is crucial during installation to maintain reliable electrical connections and prevent overheating.


Operation of the 3VA1220-6EE32-0AA0 focuses on reliable protection and ease of use. The front-accessible rotary handle allows for manual ON/OFF operation and tripping. The ETU320 features a clear display and intuitive controls for setting protective parameters. In the event of a fault, the breaker trips automatically, interrupting the circuit. To reset, the breaker must be manually switched OFF and then ON again after the fault condition has been cleared. Regular visual inspections and functional testing, as per industry best practices, are recommended to ensure continued operational integrity and mitigate potential risks.


Scalability and long-term value are inherent in the Siemens 3VA line. The 3VA1220-6EE32-0AA0 can be part of a larger, integrated power distribution solution, compatible with other Siemens components and digital platforms like Siemens' Desigo CC or SICAM. While this specific unit is a fixed-type breaker, the broader 3VA series offers modular accessories and communication options that support evolving system requirements and the integration of Industrial IoT (IIoT) functionalities for predictive maintenance and enhanced operational insights. This future-proofs investments in electrical infrastructure.


FAQs


What is the primary function of the Siemens 3VA1220-6EE32-0AA0?

This circuit breaker provides overcurrent and short-circuit protection for electrical circuits. It safeguards equipment by rapidly interrupting power flow during fault conditions, preventing damage. Its high breaking capacity ensures safety even with substantial fault currents.


How does the electronic trip unit (ETU320) enhance protection?

The ETU320 offers adjustable settings for precise overload and short-circuit protection. This accuracy minimizes nuisance tripping while ensuring rapid response to faults. It allows for tailored protection curves specific to the protected equipment's needs.


What are the typical applications for this MCCB?

It is commonly used in industrial power distribution systems and motor control centers. Applications include protecting main feeders, large motors, transformers, and distribution panels in manufacturing and commercial facilities.


What are the key technical specifications of the 3VA1220-6EE32-0AA0?

This breaker features a 250A rated current, 3 poles, and a high breaking capacity of 36kA at up to 690V AC. It utilizes an electronic trip unit for advanced protection and is designed for fixed mounting.


What are the advantages of the high breaking capacity (36kA)?

A 36kA breaking capacity means the breaker can safely interrupt extremely high fault currents. This is crucial in systems with potential for severe short circuits, ensuring personnel safety and preventing catastrophic equipment failure.


How is the Siemens 3VA1220-6EE32-0AA0 installed?

The breaker supports fixed mounting with flexible connection options, including front and rear terminals. Proper torque must be applied to all connections for reliable operation and thermal management. Consult the manual for specific wiring diagrams.


Can this breaker be integrated with digital monitoring systems?

Yes, optional communication modules can be added to the 3VA1220-6EE32-0AA0. These modules enable integration with SCADA systems, building management platforms, and IIoT solutions for remote monitoring and control.


What is the operational procedure for resetting the breaker after a trip?

After a fault causes the breaker to trip, the cause must be identified and rectified. The breaker handle is then moved to the OFF position before returning it to the ON position to restore power.


How does this breaker contribute to system reliability and uptime?

Its precise electronic protection minimizes false trips, ensuring continuous operation where possible. Rapid fault interruption prevents damage, reducing costly downtime and repairs. Its robust design also ensures longevity.


What standards does the 3VA1220-6EE32-0AA0 comply with?

This molded case circuit breaker complies with the internationally recognized IEC 60947-2 standard for low-voltage switchgear and controlgear. This ensures it meets rigorous safety and performance requirements.