ABB ACS380-040S-17A0-4 Fan Pump Frequency Inverter 17A 7.5kW

stars
  • Availability:In Stock
  • Brand:ABB
  • Model:ACS380-040S-17A0-4
  • HS: 85044099.8
Availability:In Stock
$456.96
zhongpingtech

The ABB ACS380-040S-17A0-4 is a robust 7.5kW, 17A fan and pump variable frequency inverter engineered for precise motor control in demanding industrial environments. This drive excels in optimizing energy consumption and enhancing process efficiency through its advanced features, including a built-in common mode filter, selectable relay outputs, and robust protection mechanisms. Its compact design and user-friendly interface facilitate seamless integration and operation, making it an ideal choice for a wide array of applications in HVAC, water treatment, and general industrial processes. The ACS380 series, with the ACS380-040S-17A0-4 model at its forefront, is recognized for its reliability and performance, solidifying ABB's position as a leader in motor control technology.


Product Specifications


| Parameter                 | Value                                       |

| :------------------------ | :------------------------------------------ |

| Model Number              | ACS380-040S-17A0-4                          |

| Rated Current (Inverter)  | 17 A                                        |

| Rated Power (kW)          | 7.5 kW                                      |

| Input Voltage             | 380-480 V, 3-phase                          |

| Output Voltage            | 0-100% of input voltage                     |

| Frequency Range           | 0-500 Hz                                    |

| Protection Class          | IP20                                        |

| Dimensions (H x W x D)    | 286 x 148 x 171 mm                          |

| Weight                    | 5.5 kg                                      |

| Ambient Temperature Range | -10°C to 50°C (derating may apply)           |

| Built-in Common Mode Filter | Yes                                         |

| Relay Outputs             | Selectable (2)                              |

| Digital Inputs            | 6 (configurable)                            |

| Analog Inputs             | 2 (configurable)                            |


Core Features & Market Positioning


The ABB ACS380-040S-17A0-4 distinguishes itself in the market through its inherent suitability for fan and pump applications, a niche where precise flow and pressure control are paramount. Its design incorporates an integrated common mode filter, simplifying installation by eliminating the need for external filtering in many scenarios, thereby reducing cost and complexity. This focus on application-specific functionality, combined with ABB's reputation for robust and reliable industrial automation solutions, positions the ACS380 series as a dependable and high-performance option for engineers and facility managers. The drive's inherent energy-saving capabilities, a critical factor in today's operational cost landscape, further enhance its market appeal.


Key Application Scenarios


This ABB inverter is exceptionally well-suited for variable torque applications such as centrifugal fans and pumps, where motor speed directly correlates with power consumption, offering significant energy savings. It is widely deployed in Building Management Systems (BMS) for HVAC fan and pump control, ensuring optimal air circulation and water pressure while minimizing energy usage. In water and wastewater treatment facilities, the ACS380-040S-17A0-4 provides efficient and reliable control for pumping stations, optimizing fluid transfer and reducing operational expenditures. Its robust construction and protection features also make it suitable for other general industrial tasks requiring variable speed control of motor-driven equipment.


Practical System Integration Guidance


Integrating the ABB ACS380-040S-17A0-4 into an existing system is streamlined by its flexible parameter settings and clear wiring diagrams. For typical fan and pump applications, connect the power supply to the main terminals, ensuring correct phasing. Motor connections are made to terminals U, V, and W. Digital and analog inputs can be configured to accept signals from sensors (e.g., pressure, temperature) or control systems, enabling closed-loop operation. For commissioning, using the intuitive control panel or ABB's Drive Composer software allows for efficient parameter adjustment, motor tuning, and the creation of custom application macros tailored to specific fan or pump characteristics.


Operation and Risk Mitigation


Safe operation of the ABB ACS380-040S-17A0-4 requires adherence to electrical safety standards and proper installation procedures. Ensure all power sources are disconnected and locked out before performing any wiring or maintenance. Common operational issues may include motor overload or under-voltage faults, often stemming from incorrect parameter settings or unstable power supply. The drive features comprehensive internal diagnostics to identify and report faults, such as "Overcurrent" or "Heatsink Temperature High," with corresponding error codes displayed on the control panel. Proper ventilation around the inverter is crucial to prevent overheating and ensure reliable performance, especially in higher ambient temperatures where derating might be necessary.


Scalability & Long-Term Value


The ABB ACS380-040S-17A0-4 offers excellent long-term value through its compatibility with ABB's broader automation ecosystem and its inherent design for efficiency. While this specific model is optimized for certain power and current ratings, ABB's extensive product portfolio allows for scalable solutions across different applications and plant sizes, ensuring future expansion compatibility. Integration with industrial control systems like PLCs via standard communication protocols (e.g., Modbus RTU, built-in) enables seamless incorporation into smart factory and IIoT environments, facilitating remote monitoring, data acquisition, and predictive maintenance strategies. This forward-looking design ensures that the ACS380-040S-17A0-4 remains a relevant and valuable asset throughout its operational lifespan.


Frequently Asked Questions


Q1: What are the primary benefits of using the ABB ACS380-040S-17A0-4 for fan and pump applications?


This inverter offers significant energy savings by matching motor speed to system demand precisely. It provides enhanced process control, leading to consistent output and reduced wear on equipment. The integrated common mode filter simplifies installation and reduces component count.


Q2: Can the ABB ACS380-040S-17A0-4 be directly connected to a 500V motor?


The drive's output voltage is typically 0-100% of the input voltage. For a 380-480V input, the output can match this range. Ensure motor nameplate voltage is compatible with the drive's output voltage capability.


Q3: What is the IP rating of the ABB ACS380-040S-17A0-4 and what does it signify?


The IP20 rating means the drive is protected against solid objects greater than 12.5mm but has no protection against water. It's designed for clean, dry industrial environments. Proper enclosure may be needed for harsher conditions.


Q4: How do I set up the ABB ACS380-040S-17A0-4 for a basic fan application?


Connect power and motor leads, then use the control panel to set basic parameters like ramp times and max/min frequency. Select the appropriate motor data and ensure the correct reference source is chosen for speed control.


Q5: What type of motor is recommended for use with the ACS380-040S-17A0-4?


This inverter is designed for standard 3-phase induction motors. For optimal performance and energy efficiency, ABB recommends using motors designed for variable speed drive applications.


Q6: What are the typical installation requirements for the ACS380-040S-17A0-4?


Install the drive vertically in a clean, dry environment with adequate ventilation. Ensure sufficient clearance around the unit for heat dissipation. Follow local electrical codes and ABB's installation manual precisely.


Q7: How does the ACS380-040S-17A0-4 contribute to energy efficiency in pumping systems?


By precisely controlling pump speed, the drive reduces energy consumption significantly compared to fixed-speed operation or mechanical throttling. This direct relationship between speed and power translates to substantial operational cost savings over time.


Q8: What communication protocols does the ABB ACS380-040S-17A0-4 support for integration?


This drive typically supports Modbus RTU as a standard communication protocol. Optional fieldbus adapters can enable compatibility with other industrial networks like Profibus DP or EtherNet/IP.


Q9: How can I troubleshoot common faults like "Overcurrent" on the ACS380-040S-17A0-4?


Check motor connections for short circuits. Verify that the motor and drive parameters are correctly set, especially the motor nominal current and rated power. Ensure the acceleration ramp is not too short for the connected load.


Q10: Is the ABB ACS380-040S-17A0-4 suitable for outdoor use without an enclosure?


No, the IP20 rating indicates it is not suitable for direct outdoor exposure. It requires protection from dust, moisture, and extreme temperatures, typically within an industrial control panel or enclosure.

Menu