The DANFOSS iC2-30FA1N02-04A2E20F4+ACXX 0.75kW 4.2A 1AC 200-240V iC2-30 inverter is a sophisticated variable frequency drive designed for precise motor control and energy efficiency in industrial applications. This unit boasts a compact design, robust build quality, and advanced features that position it as a leading solution for a wide range of machinery. Its 0.75kW power output, 4.2A current rating, and 200-240V single-phase input make it ideal for numerous automation tasks, offering superior performance and reliability. The iC2-30 series is engineered to deliver exceptional dynamic performance and precise speed regulation, ensuring optimal operation for demanding applications.
Product Specifications
| Parameter | Value |
| :------------------------ | :----------------------------------------- |
| Model Number | iC2-30FA1N02-04A2E20F4+ACXX |
| Power Rating | 0.75 kW |
| Full Load Current | 4.2 A |
| Input Voltage | 1-AC 200-240 V |
| Output Frequency | 0-500 Hz |
| Protection Class | IP20 |
| Dimensions (H x W x D) | 233 x 140 x 154 mm |
| Ambient Temperature Range | -10°C to +50°C (derating above 40°C) |
| Mounting Type | Wall/Panel Mount |
Core Features & Market Positioning
The DANFOSS iC2-30FA1N02-04A2E20F4+ACXX stands out in the competitive VFD market due to its advanced control algorithms and user-friendly interface. Its integrated fieldbus communication options facilitate seamless integration into various automation systems, enhancing its appeal for modern industrial setups. Danfoss's reputation for durability and innovation underpins the iC2-30's market position as a reliable and high-performance drive. The inverter's ability to handle demanding applications with precision, such as precise speed control for conveyor systems or torque control for material handling, demonstrates its technological differentiation.
Key Application Scenarios
This iC2-30 inverter is particularly well-suited for applications requiring precise motor speed and torque control. Common use cases include pumps and fans in HVAC systems, where variable speed operation leads to significant energy savings and optimized performance. It is also extensively used in material handling equipment, such as conveyors, elevators, and cranes, where smooth acceleration and deceleration are critical. Furthermore, its capabilities extend to machine tools, packaging machinery, and other process industries where consistent and accurate motor performance is paramount for product quality and operational efficiency.
Practical System Integration Guidance
Integrating the DANFOSS iC2-30FA1N02-04A2E20F4+ACXX into an existing system is streamlined by its flexible configuration options. Proper wiring is crucial for safe and optimal operation; ensure the input power (1-AC 200-240V) is correctly connected to terminals L1 and L2, and the motor is connected to terminals U, V, and W. For commissioning, it is recommended to set motor parameters such as nominal power, voltage, frequency, and current, which are typically found on the motor's nameplate. The intuitive control panel allows for easy parameter adjustment, and advanced configuration for PID control or communication protocols can be accessed via dedicated menu structures, often detailed in the product manual.
Operation and Risk Mitigation
Operating the iC2-30 inverter requires adherence to electrical safety standards. Always ensure power is disconnected before making any wiring changes or performing maintenance. The IP20 protection class indicates it is designed for indoor use in environments free from conductive dust or excessive moisture. Familiarize yourself with the inverter's fault codes; common errors like "Overcurrent" or "Overtemperature" often indicate issues with motor load, wiring, or ambient conditions. Promptly addressing these faults by consulting the troubleshooting section of the user manual is vital to prevent equipment damage and ensure continuous operation.
Scalability & Long-Term Value
The iC2-30 series offers a degree of scalability through its compatibility with various communication protocols, allowing it to integrate with higher-level control systems like PLCs and SCADA. This ensures that as automation needs evolve, the drive can remain a central component of a modernized system. Its robust construction and Danfoss's commitment to product longevity contribute to its long-term value. For organizations looking to implement Industrial IoT (IIoT) strategies, the iC2-30 can be equipped with optional communication modules, enabling remote monitoring, diagnostics, and data collection, thus enhancing predictive maintenance capabilities and overall operational intelligence.
Frequently Asked Questions
1. What is the power rating of the DANFOSS iC2-30FA1N02-04A2E20F4+ACXX inverter?
The DANFOSS iC2-30FA1N02-04A2E20F4+ACXX inverter has a power rating of 0.75 kW. This output capacity is suitable for a wide range of industrial motors.
This specific power rating makes it an efficient choice for many common automation tasks. It balances performance with energy consumption effectively.
The 0.75 kW rating positions this VFD for applications that do not require extremely high power but demand precise control and reliability.
2. What is the input voltage range for this iC2-30 inverter?
This DANFOSS iC2-30 inverter operates on a single-phase AC input voltage range of 200 to 240 Volts. This is a standard voltage for many industrial and commercial power grids.
Ensuring the local power supply is within this 200-240V range is critical for correct and safe operation. Incorrect voltage can lead to malfunctions or damage.
The 1-AC 200-240V specification highlights its suitability for diverse electrical environments and installations.
3. Can the DANFOSS iC2-30FA1N02-04A2E20F4+ACXX inverter be used with three-phase motors?
Yes, the DANFOSS iC2-30FA1N02-04A2E20F4+ACXX inverter is designed to control three-phase motors. Despite having a single-phase input, it generates a three-phase output for motor operation.
This capability allows it to be installed in locations with only single-phase power availability while still driving standard three-phase industrial motors. It's a common setup for smaller machines.
The drive's internal circuitry converts the single-phase input into a variable frequency, variable voltage three-phase output to effectively control the motor's speed and torque.
4. What is the maximum full-load current for the iC2-30FA1N02-04A2E20F4+ACXX?
The maximum full-load current for this DANFOSS iC2-30 inverter is rated at 4.2 Amps. This current rating is a key parameter for motor selection and system design.
When selecting a motor to be driven by this inverter, its full-load current should not exceed this 4.2A rating for optimal performance and safety.
This 4.2A capacity ensures the drive can adequately power motors within its 0.75kW specification while maintaining operational stability.
5. What type of protection does the iC2-30FA1N02-04A2E20F4+ACXX offer against environmental factors?
The DANFOSS iC2-30FA1N02-04A2E20F4+ACXX inverter features an IP20 protection rating. This signifies it is protected against solid objects larger than 12.5mm but offers no protection against water ingress.
Due to its IP20 rating, this inverter is intended for installation in clean, dry indoor environments. It should be protected from dust, moisture, and corrosive elements.
Proper installation within an enclosure or control cabinet is recommended to maintain the integrity of its IP20 rating and ensure longevity.
6. How is the DANFOSS iC2-30FA1N02-04A2E20F4+ACXX inverter commissioned?
Commissioning involves correctly wiring the power supply and motor, then configuring essential motor parameters via the user interface. Key settings include motor's rated power, voltage, current, and frequency.
It's crucial to perform auto-tuning or manual parameterization of motor data for optimal performance and protection. The drive's manual provides detailed step-by-step instructions.
After initial setup, test the drive with a light load, gradually increasing it while monitoring performance and checking for any fault indications.
7. What are the typical applications for the DANFOSS iC2-30FA1N02-04A2E20F4+ACXX?
This inverter is commonly applied in variable speed drives for pumps, fans, and general machinery in sectors like HVAC, material handling, and packaging. Its precise control is vital.
It excels in applications where energy efficiency is a priority, such as adjusting fan speeds based on demand or controlling pump flow rates.
Machine builders often select this VFD for its compact size and ease of integration into control panels for a variety of automated equipment.
8. What communication protocols does this iC2-30 inverter support?
The DANFOSS iC2-30FA1N02-04A2E20F4+ACXX supports common fieldbus protocols through optional communication modules. This allows integration into sophisticated automation systems.
Protocols like Modbus RTU are often available, enabling remote control, parameter setting, and status monitoring from a PLC or HMI.
The flexibility to add communication modules enhances its capability for integration into Industrial IoT (IIoT) platforms for advanced diagnostics and data analysis.
9. What is the ambient temperature range for operating the iC2-30FA1N02-04A2E20F4+ACXX?
The DANFOSS iC2-30FA1N02-04A2E20F4+ACXX can operate in an ambient temperature range of -10°C to +50°C. However, derating is required for temperatures above 40°C.
Operating above 40°C necessitates reducing the motor's load current to prevent overheating and ensure the inverter's longevity. The specific derating curve is in the manual.
Adequate ventilation is essential for maintaining optimal operating temperatures, especially in enclosed control cabinets, to avoid exceeding the operational limits.
10. Where can I find the user manual for the DANFOSS iC2-30FA1N02-04A2E20F4+ACXX?
The official user manual for the DANFOSS iC2-30FA1N02-04A2E20F4+ACXX can be downloaded from the Danfoss official website. Search for the product model number.
The manual contains comprehensive details on installation, wiring, parameter settings, troubleshooting, and safety precautions vital for its operation.
It is highly recommended to thoroughly review the manual before installation and commissioning to ensure proper and safe usage of the VFD.