Siemens 5SN6216-7CN MCB for Small Appliance Protection 2P 16A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6216-7CN
  • HS: 85362030
Availability:In Stock
$7.68
zhongpingtech

The Siemens 5SN6216-7CN MCB offers robust and reliable protection for small appliances, boasting a 2-pole configuration and a 16A current rating. This Miniature Circuit Breaker (MCB) is engineered with advanced tripping characteristics to safeguard circuits from overloads and short circuits, ensuring operational continuity and preventing equipment damage. Its compact design facilitates easy integration into various electrical panels, making it a versatile solution for residential, commercial, and light industrial applications requiring dependable circuit protection. Key technical parameters include its 2P (2-pole) design, a nominal current (In) of 16A, and compliance with relevant international safety standards, assuring users of its high performance and safety credentials.


Siemens 5SN6216-7CN MCB: Product Specifications


| Parameter                  | Specification                                |

| :------------------------- | :------------------------------------------- |

| Product Type               | Miniature Circuit Breaker (MCB)              |

| Manufacturer               | Siemens                                      |

| Model Number               | 5SN6216-7CN                                  |

| Number of Poles            | 2 (2P)                                       |

| Rated Current (In)         | 16A                                          |

| Tripping Characteristic    | Typically Type C (for inductive loads) |

| Rated Voltage (Ue)         | 230/400V AC (dependent on specific variant) |

| Breaking Capacity (Icn)    | 6kA (common for this series)       |

| Frequency                  | 50/60 Hz                                     |

| Protection Class           | IP20 (enclosure)                             |

| Operating Temperature      | -25°C to +45°C                               |

| Mounting Type              | DIN rail (35mm)                              |

| Compliance Standards       | IEC/EN 60898-1, IEC/EN 60947-2               |


Core Features & Market Positioning


The Siemens 5SN6216-7CN MCB distinguishes itself through its reliable Siemens engineering, a hallmark of quality and durability in the electrical components market. Its precision tripping mechanisms, often featuring Type C characteristics, are optimized for protecting inductive loads common in small appliances, offering enhanced safety beyond basic overcurrent protection. This MCB is positioned as a dependable, cost-effective solution for applications where consistent circuit integrity and equipment longevity are paramount. Its compatibility with standard DIN rail mounting systems simplifies installation and retrofitting, making it an attractive choice for electricians and panel builders seeking robust and user-friendly circuit protection devices. The robust construction ensures resilience in diverse operational environments, reinforcing its value proposition for critical small appliance circuits.


Key Application Scenarios


This Siemens 5SN6216-7CN MCB is ideally suited for safeguarding a wide array of small appliances and circuits in residential, commercial, and light industrial settings. Common applications include protection for kitchen appliances like refrigerators and microwaves, office equipment such as computers and printers, and lighting circuits. Its 2-pole design is essential for applications requiring disconnection of both live and neutral conductors, a critical safety feature for many small appliance circuits. Furthermore, it finds utility in protecting smaller motor loads, air conditioning units, and power distribution boards where precise and responsive overcurrent and short-circuit protection is necessary to prevent downtime and equipment failure.


Practical System Integration Guidance


Integrating the Siemens 5SN6216-7CN MCB into existing or new electrical systems is straightforward due to its standard DIN rail mounting capability. Ensure the MCB is installed in a suitable enclosure providing adequate ventilation and protection from environmental factors. The 2-pole configuration necessitates connecting both the line and neutral conductors to their respective terminals on the MCB. Proper torque should be applied to the terminal screws to ensure secure connections and prevent overheating. Before energizing the circuit, verify correct wiring and ensure no short circuits exist. For safety, always disconnect power from the main supply before commencing any installation work.


Operation and Risk Mitigation


The Siemens 5SN6216-7CN MCB operates automatically, interrupting the circuit when an overcurrent or short-circuit fault is detected, thereby preventing potential fire hazards and equipment damage. Its thermal-magnetic tripping mechanism ensures rapid response to fault conditions. Risk mitigation is inherent in its design; however, users must adhere to installation guidelines and ensure the MCB is correctly rated for the connected load. Avoid resetting the breaker repeatedly without identifying and rectifying the fault. If nuisance tripping occurs, consult the tripping characteristic (e.g., Type C) and consider the nature of the load; persistent issues may indicate an underlying circuit problem or an undersized MCB.


Scalability & Long-Term Value


While the Siemens 5SN6216-7CN MCB is designed for specific circuit protection roles, its long-term value is enhanced by Siemens' commitment to quality and compatibility within their broader electrical product ecosystem. Although direct "scalability" in terms of upgrading a single MCB is limited, its integration into larger Siemens-based distribution boards allows for system-wide upgrades and expansions. Compatibility with other Siemens components, such as busbars and terminal blocks, simplifies the design and construction of more complex electrical installations. For users looking towards future digitalization, Siemens' infrastructure often supports integration with smart metering and monitoring systems, providing pathways for enhanced energy management and predictive maintenance, even for basic protection devices.


Frequently Asked Questions (FAQs)


1. What type of tripping characteristic does the Siemens 5SN6216-7CN MCB typically have?


The Siemens 5SN6216-7CN MCB commonly features a Type C tripping characteristic.

This characteristic is designed to handle moderate inrush currents typical of inductive loads.

It provides reliable protection for small motors and appliances without nuisance tripping.


2. What is the breaking capacity of the Siemens 5SN6216-7CN MCB?


The breaking capacity is typically rated at 6kA.

This means it can safely interrupt fault currents up to 6000 Amperes.

It is suitable for most residential and light commercial distribution circuits.


3. Can this MCB be used for both AC and DC circuits?


This MCB is primarily designed for AC circuits.

It is not suitable for DC circuit protection applications.

Always verify the product datasheet for specific voltage ratings and application suitability.


4. How do I wire the Siemens 5SN6216-7CN MCB?


Connect the incoming live conductor to the top terminal.

Connect the outgoing live conductor to the other top terminal.

Connect the neutral conductor to the neutral terminal; ensure proper DIN rail grounding.


5. What does "2P" mean in the Siemens 5SN6216-7CN MCB designation?


"2P" signifies that the circuit breaker has two poles.

It is designed to interrupt both the live and neutral conductors simultaneously.

This ensures complete isolation of the circuit during a fault or for maintenance.


6. What are the dimensions and mounting requirements for this MCB?


It is designed for standard 35mm DIN rail mounting.

Its compact size facilitates installation in standard electrical panels.

Refer to the technical datasheet for exact physical dimensions.


7. What is the purpose of the 16A rating on this MCB?


The 16A rating indicates the maximum continuous current the MCB can carry.

It protects circuits from overloads exceeding 16 Amperes.

Loads drawing more than 16A for extended periods will cause tripping.


8. Is this MCB suitable for industrial machinery protection?


While robust, it's primarily for small appliance protection.

Industrial machinery may require higher breaking capacities or specific tripping curves.

Consult a qualified electrician for industrial applications.


9. What standards does the Siemens 5SN6216-7CN MCB comply with?


It complies with IEC/EN 60898-1 and IEC/EN 60947-2 standards.

These standards ensure safety and performance in circuit protection devices.

Compliance ensures reliability and interoperability within specified systems.


10. How does this MCB protect against short circuits?


It uses a magnetic tripping mechanism for instantaneous response.

This mechanism reacts quickly to very high fault currents.

Rapid interruption prevents damage from severe short circuits.