Siemens 5SN6620-7CN MCB Dedicated for Pumps and Fans 3P+N 20A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6620-7CN
  • HS: 85362030
Availability:In Stock
$15.32
zhongpingtech

The Siemens 5SN6620-7CN Miniature Circuit Breaker (MCB) is engineered as a specialized protective device for pumps and fans, offering robust 3-pole + Neutral protection and a 20A rating. This dedicated MCB ensures reliable circuit interruption and overload protection, safeguarding motor-driven equipment from electrical faults. Its advanced tripping characteristics are optimized for the unique inductive loads of pumps and fans, minimizing nuisance tripping while providing essential safety. Key technical parameters include a rated voltage of 400V AC, a breaking capacity of 6kA, and a Type C tripping curve, ideal for motor applications.


Siemens 5SN6620-7CN: Product Specifications


| Feature                 | Specification                     |

| :---------------------- | :-------------------------------- |

| Product Type            | Miniature Circuit Breaker (MCB)   |

| Poles                   | 3P + N (3-Pole + Neutral)         |

| Rated Current           | 20A                               |

| Rated Voltage           | 400V AC                           |

| Breaking Capacity (Icn) | 6kA                               |

| Tripping Curve          | Type C                            |

| Mounting                | DIN Rail                          |

| Protection Type         | Overload and Short Circuit        |

| Application             | Pumps and Fans                    |

| Compliance              | IEC/EN 60898-1                    |

| Dimensions (H x W x D)  | 87.9mm x 70mm x 77.5mm            |

| Operating Temperature   | -25°C to +55°C                    |

| Terminal Type           | Box Terminal                      |


Core Features & Market Positioning


The Siemens 5SN6620-7CN distinguishes itself through its application-specific design for pump and fan circuits. Unlike general-purpose MCBs, its Type C tripping curve is meticulously calibrated to handle the high inrush currents typical of motor start-ups without premature tripping. This enhances operational continuity for critical pumping and ventilation systems. The 3P+N configuration provides comprehensive protection for single-phase loads requiring a neutral connection, ensuring safety and compliance for these specific motor configurations. Siemens' reputation for quality and reliability further solidifies its market position as a trusted component for industrial automation and building services.


Key Application Scenarios


This MCB is ideally suited for protecting a wide array of pumps and fans across various industrial and commercial sectors. Applications include HVAC systems where reliable fan operation is paramount for climate control, and water management systems where pump failure can lead to significant operational disruptions. It is also extensively used in sewage and drainage systems, industrial ventilation, and machine tool cooling circuits. The 20A rating and 6kA breaking capacity make it suitable for medium-sized pump and fan installations commonly found in process industries, manufacturing plants, and large commercial buildings.


Practical System Integration Guidance


Integrating the Siemens 5SN6620-7CN MCB into existing electrical systems is straightforward due to its standard DIN rail mounting. Ensure the incoming power supply is de-energized before installation. Connect the phase conductors (L1, L2, L3) and the neutral conductor to the corresponding terminals on the MCB. The load terminals then connect to the pump or fan motor control circuit. Proper wiring gauge selection, in accordance with local electrical codes and the MCB's 20A rating, is crucial for safe and efficient operation. Grounding connections should be made to the system's main earth ground.


Operation and Risk Mitigation


The Siemens 5SN6620-7CN operates by continuously monitoring the current flowing through the protected circuit. In the event of an overload (current exceeding the 20A rating for an extended period) or a short circuit (a sudden, drastic increase in current), the MCB's internal thermal or magnetic tripping mechanism activates, rapidly interrupting the power supply. This prevents overheating of motor windings and damage to connected equipment, thereby mitigating fire hazards and costly repairs. Regular visual inspection for signs of wear or damage and periodic testing of the tripping function are recommended to ensure continued operational safety.


Scalability & Long-Term Value


While the Siemens 5SN6620-7CN is a dedicated component, its integration within a broader Siemens automation ecosystem offers scalability. It can be part of larger motor control centers (MCCs) or integrated with programmable logic controllers (PLCs) and supervisory control and data acquisition (SCADA) systems for remote monitoring and control. This allows for enhanced diagnostics, predictive maintenance capabilities, and optimized operational management of pump and fan systems. Its robust construction ensures a long service life, contributing to the overall long-term value and reliability of the electrical installation.


Frequently Asked Questions (FAQs)


What is the primary application for the Siemens 5SN6620-7CN MCB?

This MCB is specifically designed for protecting pumps and fans. Its Type C tripping curve is ideal for handling motor inrush currents.


It ensures reliable operation by preventing nuisance tripping during motor start-ups. This dedicated design enhances equipment longevity.


It is suitable for various industrial and commercial applications requiring motor protection. It ensures safe and continuous operation.


What does the "3P+N" configuration mean for this MCB?

"3P+N" signifies that the MCB has three poles for the phase conductors and a dedicated pole for the neutral conductor. This offers comprehensive protection for circuits where a neutral connection is required.


It provides isolation and protection for all conductors, including neutral, which is vital for certain motor types and wiring configurations. This ensures electrical safety.


This configuration is common for specific pump and fan motor installations that require balanced protection across all supply lines. It enhances system safety.


What is the breaking capacity of the Siemens 5SN6620-7CN, and why is it important?

The breaking capacity (Icn) of 6kA indicates the maximum fault current the MCB can safely interrupt without sustaining damage. This is critical for system safety.


A higher breaking capacity ensures the MCB can effectively clear short circuits in installations with potentially high fault currents. It prevents catastrophic damage.


Selecting an MCB with adequate breaking capacity is essential to protect downstream equipment and personnel from the hazards of severe electrical faults. It is a key safety parameter.


Can the Siemens 5SN6620-7CN be used for general lighting circuits?

While it can technically interrupt current for lighting, its Type C tripping curve is optimized for inductive loads like motors, not resistive loads. This can lead to over-protection.


General lighting circuits typically utilize MCBs with Type B or Type C curves, but the specific calibration of this MCB is best suited for motor applications. It's designed for specific needs.


Using this MCB for lighting might result in unnecessary tripping under certain conditions, compromising the reliability of the lighting system. It is not its primary function.


What are the advantages of a Type C tripping curve for pumps and fans?

A Type C curve allows for higher inrush currents during motor start-up without tripping. This is crucial for motor longevity.


Motors draw significantly more current when starting than during normal operation; the Type C curve accommodates this transient demand. It ensures operational continuity.


This characteristic prevents nuisance tripping, which can disrupt processes and lead to unnecessary downtime and maintenance. It enhances system availability.


How do I correctly wire the Siemens 5SN6620-7CN MCB?

Ensure the power supply is OFF before wiring to prevent electrical shock. Connect phase conductors L1, L2, L3, and the neutral conductor to their respective terminals.


The load side terminals should then be connected to the pump or fan control wiring. Always use appropriate wire gauges for the 20A rating.


Proper grounding of the system and enclosure connected to the MCB is also a critical safety step. Consult local codes for specific requirements.


What is the operating temperature range for this MCB?

The Siemens 5SN6620-7CN is designed to operate reliably within an ambient temperature range of -25°C to +55°C. This ensures performance in diverse environments.


Operating outside this specified range can affect the MCB's performance, potentially leading to premature tripping or failure to trip correctly. Temperature impacts reliability.


It's important to ensure that the installation environment for the MCB stays within these limits to guarantee its long-term functionality and safety. Monitor ambient conditions.


Is this MCB compatible with Siemens S200 or S7 series products?

The 5SN6620-7CN is part of Siemens' extensive range of circuit protection devices, designed for broad compatibility within their industrial control and automation platforms. It integrates well.


It can be readily integrated into motor control centers and control panels that utilize Siemens components, including PLCs like the S7 series for enhanced system integration. It supports automation.


Its standard DIN rail mounting and common terminal types ensure straightforward integration with various Siemens electrical and automation systems for comprehensive solutions. It offers flexibility.


What type of faults does this MCB protect against?

This MCB provides protection against overcurrents, specifically both overload conditions and short circuits. These are common electrical hazards.


Overload protection prevents damage from sustained excessive current, while short-circuit protection reacts rapidly to very high fault currents. It covers critical scenarios.


By interrupting the circuit during these fault conditions, the MCB safeguards connected equipment, wiring, and prevents potential fire hazards. It ensures safety.


How does the "dedicated for pumps and fans" designation benefit my system?

This designation means the MCB's tripping characteristics are specifically tuned for the electrical behavior of pump and fan motors. This minimizes false trips.


It ensures that the motor can start reliably under varying load conditions without the MCB unnecessarily disconnecting power. This improves uptime.


The specialized design contributes to the overall reliability and lifespan of pump and fan equipment by providing appropriate protection tailored to their unique operational demands. It optimizes performance.

Menu