Siemens 5SN6513-8CN High Breaking Capacity MCB for Motor Starting 1P+N 13A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6513-8CN
  • HS: 85362030
Availability:In Stock
$8.81
zhongpingtech

The Siemens 5SN6513-8CN is a single-pole plus neutral, 13A Miniature Circuit Breaker (MCB) engineered with High Breaking Capacity (HBC) specifically for motor starting applications. This advanced protection device offers superior short-circuit withstand capability, ensuring robust safety and operational reliability in demanding industrial environments. Its key advantages lie in its precision tripping characteristics tailored for motor inrush currents, preventing nuisance tripping while safeguarding against overloads and short circuits. The 5SN6513-8CN boasts a breaking capacity of 10kA, a rated voltage of 230/400V AC, and utilizes a thermal-magnetic tripping mechanism, making it an essential component for protecting single-phase motor circuits.


Siemens 5SN6513-8CN: Product Specifications


| Feature                  | Specification                 |

| :----------------------- | :---------------------------- |

| Product Type             | Miniature Circuit Breaker (MCB) |

| Model Number             | 5SN6513-8CN                   |

| Pole Configuration       | 1P+N (Single Pole + Neutral)  |

| Rated Current (In)       | 13A                           |

| Breaking Capacity (Icn)  | 10kA                          |

| Rated Voltage (Ue)       | 230/400V AC                   |

| Tripping Mechanism       | Thermal-Magnetic              |

| Frequency                | 50/60 Hz                      |

| Protection Class         | IP20                          |

| Terminal Type            | Screw Terminal                |

| Mounting Type            | DIN Rail                      |

| Compliance Standards     | IEC/EN 60898-1, IEC/EN 60947-2 |


Core Features & Market Positioning


The Siemens 5SN6513-8CN distinguishes itself through its high breaking capacity, a critical feature for reliably interrupting fault currents in circuits powering motors. This capability minimizes damage to downstream equipment and wiring during short-circuit events. Its specialized design for motor starting addresses the common challenge of high inrush currents, which can falsely trigger standard MCBs. By incorporating a carefully calibrated thermal-magnetic tripping unit, the 5SN6513-8CN ensures that transient motor start-up currents do not lead to unnecessary shutdowns, thereby enhancing operational uptime. This makes it a preferred choice for applications where motor reliability is paramount, positioning it as a robust and dependable solution within Siemens' comprehensive industrial circuit protection portfolio.


Key Application Scenarios


This 13A MCB is ideally suited for protecting single-phase motor circuits commonly found in various industrial and commercial settings. This includes the protection of small pumps, fans, conveyors, compressors, and other motor-driven equipment where precise and reliable circuit interruption is essential. Its 1P+N configuration is particularly beneficial for circuits that require both phase and neutral protection, ensuring complete isolation. Applications in HVAC systems, small manufacturing lines, and building services electrical installations are prime examples where the Siemens 5SN6513-8CN delivers optimal performance and safety.


Practical System Integration Guidance


Integrating the Siemens 5SN6513-8CN into existing electrical panels is straightforward due to its standard DIN rail mounting. Ensure that the incoming phase and neutral conductors are connected to the appropriate terminals, observing correct polarity. The outgoing load conductors should then be connected to the output terminals. It is crucial to verify that the ambient temperature and environmental conditions are within the MCB's operating limits (typically -25°C to +55°C). For optimal safety and performance, always ensure the circuit's total load does not exceed the MCB's rated current of 13A, and that the wiring gauge is appropriate for the current and installation method.


Operation and Risk Mitigation


The Siemens 5SN6513-8CN operates by continuously monitoring the current flowing through the circuit. In case of an overload, the thermal element heats up and triggers the mechanism to open the circuit. For sudden, high-magnitude short-circuit currents, the magnetic element provides an instantaneous trip. This dual-action protection minimizes the risk of electrical fires, equipment damage, and personal injury. To mitigate risks, regular inspection of the MCB and associated wiring for signs of wear or damage is recommended. Ensure that the MCB is correctly rated for the connected load and that authorized personnel perform any maintenance or replacement tasks.


Scalability & Long-Term Value


The Siemens 5SN6513-8CN, while a specific component, is part of Siemens' broader ecosystem of industrial automation and electrical distribution solutions. This ensures compatibility with other Siemens protective devices, control gear, and intelligent electrical panels. For systems requiring future expansion or integration with advanced monitoring, the inherent quality and reliability of Siemens products provide a solid foundation. While this specific MCB is not directly programmable, its precise and consistent performance contributes to the overall stability and predictability of the electrical system, reducing the likelihood of unforeseen downtime and associated costs.


Frequently Asked Questions


What is the breaking capacity of the Siemens 5SN6513-8CN?

The Siemens 5SN6513-8CN offers a high breaking capacity of 10kA. This ensures it can safely interrupt significant fault currents. It is designed to protect circuits without sustaining damage during a short circuit event.


This robust rating is crucial for industrial motor applications. It provides reliable protection against severe electrical disturbances. The 10kA capacity meets stringent safety standards for motor circuits.


High breaking capacity is essential for preventing cascading failures in electrical distribution systems. It safeguards downstream equipment and personnel from hazardous electrical arcs. This feature is a key differentiator for demanding applications.


Can the Siemens 5SN6513-8CN be used for general lighting circuits?

While technically possible, it is not optimized for general lighting circuits. Its design prioritizes motor starting characteristics. Standard MCBs are usually more cost-effective for lighting.


The 5SN6513-8CN is specifically engineered for motor loads. It handles high inrush currents without nuisance tripping. General lighting circuits have different load profiles.


Using this specialized MCB for lighting might be an over-specification. It's best to select protective devices tailored to the specific application's demands. Always consult application guidelines for optimal use.


What type of tripping mechanism does the Siemens 5SN6513-8CN use?

This MCB utilizes a thermal-magnetic tripping mechanism. The thermal element protects against overloads. The magnetic element provides instantaneous protection against short circuits.


The thermal trip ensures protection against gradual overheating. The magnetic trip reacts swiftly to sudden fault currents. This dual protection is standard for many industrial MCBs.


This combination offers reliable and precise circuit interruption. It is a proven technology for safeguarding electrical installations. It ensures safety and operational continuity for connected loads.


Is the Siemens 5SN6513-8CN suitable for DC applications?

No, the Siemens 5SN6513-8CN is designed exclusively for AC applications. It is not rated or tested for direct current circuits. Using it on DC systems can lead to hazardous conditions.


Electrical characteristics and arc quenching differ significantly between AC and DC. DC circuits pose unique challenges for circuit breakers. Always use devices specifically designed for DC voltage and current.


The product specifications clearly indicate 230/400V AC. It complies with IEC/EN standards for AC circuits. For DC protection, consult Siemens' range of DC circuit breakers.


How does the 1P+N configuration benefit motor protection?

The 1P+N configuration provides protection for both the phase and neutral conductors. This ensures complete isolation of the motor circuit upon tripping. It enhances safety by breaking both live conductors.


For single-phase motors, switching off only the phase can leave the neutral conductor live. This poses an electrocution risk during maintenance. The 1P+N design eliminates this hazard.


This configuration offers superior safety and protection compared to a single-pole breaker in single-phase circuits. It is a critical feature for installations requiring comprehensive electrical safety. It meets stricter safety regulations.


What is the typical lifespan of a Siemens 5SN6513-8CN MCB?

The lifespan of an MCB like the 5SN6513-8CN depends on operational conditions. Frequent tripping can reduce its lifespan. Proper selection and installation are key to longevity.


Under normal operating conditions, with infrequent tripping, these devices can last for many years. Siemens products are known for their durability and reliability. Regular inspections can help ensure continued performance.


While specific years are not guaranteed, they are designed for long-term service in industrial environments. Factors like ambient temperature, humidity, and electrical load directly impact component wear.


How does the Siemens 5SN6513-8CN handle motor inrush current?

The MCB features a thermal-magnetic tripping unit carefully calibrated for motor loads. This allows for higher inrush currents during motor startup without immediate tripping. The magnetic trip curve is designed to tolerate these transient currents.


Standard MCBs might trip prematurely due to the high starting current of motors. The 5SN6513-8CN's specific tripping characteristics prevent nuisance shutdowns. This ensures reliable motor starts.


The thermal element provides overload protection, while the magnetic element offers short-circuit protection. This specific balance ensures the breaker protects the circuit without interrupting normal motor startup.


What are the implications of using an under-rated MCB for motor starting?

Using an under-rated MCB can lead to frequent nuisance tripping during motor startup. It may also fail to interrupt fault currents properly. This poses a significant risk of equipment damage and fire hazards.


An under-rated breaker may not be able to handle the high inrush current. It could also be damaged itself when interrupting a fault current it is not rated for. This compromises the entire electrical safety system.


It is critical to select an MCB with a breaking capacity and current rating suitable for the motor's power requirements and starting characteristics. Always refer to motor nameplates and electrical design specifications.


Can the Siemens 5SN6513-8CN be used in conjunction with a contactor?

Yes, this MCB is commonly used in conjunction with a contactor for motor control. The MCB provides short-circuit and overload protection. The contactor provides the switching and control for the motor.


The MCB is installed upstream of the contactor. It ensures that in case of a fault, the entire circuit, including the contactor, is de-energized. This setup offers comprehensive protection.


This combination is a standard practice in motor control circuits, providing both safety and operational flexibility for starting and stopping motors remotely or automatically.


What are the environmental operating conditions for the Siemens 5SN6513-8CN?

The Siemens 5SN6513-8CN is designed for operation within a specific temperature range, typically -25°C to +55°C. It should be installed in environments free from excessive dust, corrosive gases, or flammable materials.


Proper ventilation is important to maintain optimal operating temperatures. High ambient temperatures can affect the tripping characteristics of the MCB. It is rated with an IP20 protection class, meaning it is protected against solid objects greater than 12.5mm but not from water.


Adhering to these environmental guidelines ensures the long-term reliability and safety of the circuit breaker and the electrical installation it protects. Always check the product datasheet for precise specifications.

Menu