Siemens 5SN6563-8CN High Breaking Capacity Main Switch Breaker 1P+N 63A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6563-8CN
  • HS: 85362030
Availability:In Stock
$15.44
zhongpingtech

The Siemens 5SN6563-8CN High Breaking Capacity Main Switch Breaker is engineered for robust protection in demanding electrical systems. This 1-pole + neutral (1P+N) device offers a substantial 63A current rating and a high breaking capacity, ensuring reliable circuit interruption under fault conditions. Its key advantages lie in its superior safety features, compact design, and Siemens' renowned quality and durability, making it an ideal choice for residential, commercial, and light industrial applications requiring dependable overcurrent protection. The breaker's tripping characteristic and rated voltage are critical parameters ensuring it meets stringent safety standards.


| Specification         | Value                     |

| :-------------------- | :------------------------ |

| Product Type          | Miniature Circuit Breaker |

| Poles                 | 1P+N                      |

| Rated Current (In)    | 63A                       |

| Breaking Capacity (Icn) | 10kA                      |

| Rated Voltage (Un)    | 230/400V                  |

| Tripping Curve        | C                         |

| Frequency             | 50/60 Hz                  |

| IP Protection         | IP20                      |


Core Features & Market Positioning


The Siemens 5SN6563-8CN distinguishes itself through its high breaking capacity of 10kA, providing superior protection against short circuits compared to lower-rated breakers. This feature is paramount in installations where fault currents can be significant, offering enhanced safety and preventing extensive damage to electrical equipment. Its Type C tripping curve ensures it can handle moderate inrush currents associated with inductive loads without nuisance tripping, while still providing rapid disconnection during short circuits. This balance positions the 5SN6563-8CN as a premium, reliable solution for applications demanding robust overcurrent protection and operational stability, backed by Siemens' global reputation for electrical engineering excellence.


Key Application Scenarios


This 1P+N 63A circuit breaker is exceptionally suited for main distribution boards in residential buildings, protecting the overall power supply to individual dwellings. It is also a vital component in commercial settings for the main incomer protection of smaller distribution panels, safeguarding against overloads and short circuits in office spaces, retail outlets, and similar environments. Furthermore, its robust construction and high breaking capacity make it a suitable choice for light industrial applications, such as controlling and protecting circuits for machinery or equipment where precise and reliable fault interruption is critical.


Practical System Integration Guidance


Installing the Siemens 5SN6563-8CN involves mounting it onto a standard DIN rail within a suitable distribution enclosure. Ensure the enclosure provides adequate ventilation to maintain optimal operating temperature. For wiring, connect the line conductor to the 'L' terminal and the neutral conductor to the 'N' terminal on the load side, while the supply conductors connect to the corresponding terminals on the line side. Always ensure the main power supply is de-energized before commencing any electrical work. Proper grounding of the enclosure and associated equipment is essential for safety.


Operation and Risk Mitigation


Operating the 5SN6563-8CN is straightforward: the toggle lever serves as the manual control for switching the circuit on and off. In the event of an overcurrent or short circuit, the breaker will automatically trip, moving the lever to the 'OFF' position. To reset, ensure the fault condition has been rectified, then firmly push the toggle lever to the 'ON' position. Key risk mitigation involves regular visual inspection for any signs of damage or overheating, and ensuring the breaker is correctly rated for the protected circuit to prevent nuisance tripping or inadequate protection. Avoid operating the breaker with damaged components.


Scalability & Long-Term Value


The Siemens 5SN6563-8CN offers excellent long-term value due to its compatibility with Siemens' extensive range of modular DIN rail devices, allowing for easy expansion and modification of electrical distribution systems. It integrates seamlessly with other Siemens components, ensuring a cohesive and reliable electrical infrastructure. While not directly an IIoT device, its presence in a Siemens-based system can contribute to the overall reliability and safety of smart building or industrial automation solutions, facilitating efficient power management and diagnostics when paired with compatible monitoring systems.


Frequently Asked Questions


Q1: What is the primary function of the Siemens 5SN6563-8CN?

The Siemens 5SN6563-8CN acts as a crucial safety device in electrical circuits. It is designed to automatically interrupt the flow of electricity when an overcurrent condition occurs. This prevents damage to connected equipment and reduces the risk of electrical fires.


It specifically protects circuits from both overloads, which are prolonged excessive currents, and short circuits, which are sudden, very high current events. The 1P+N configuration means it disconnects both the live and neutral conductors simultaneously, offering enhanced safety.


This high breaking capacity breaker is rated to safely interrupt fault currents up to 10kA. This makes it suitable for use in main distribution points where fault currents can be substantial.


Q2: What does "1P+N" mean in the product name?

"1P+N" signifies that the circuit breaker has one protected pole plus a switched neutral pole. This is a common configuration for single-phase circuits in many regions.


It ensures that both the live (phase) conductor and the neutral conductor are disconnected from the power supply when the breaker trips or is manually switched off. This provides a more complete isolation of the circuit.


This type of breaker is essential for applications requiring complete isolation of both conductors, such as in some European electrical standards or for specific load types.


Q3: What is the significance of the "High Breaking Capacity" rating?

The "High Breaking Capacity" (often denoted as Icn) indicates the maximum fault current the breaker can safely interrupt without sustaining damage. A rating of 10kA means it can handle up to 10,000 Amperes of fault current.


This is a critical safety feature, especially in electrical installations where the power source can deliver very high fault currents. A breaker with insufficient breaking capacity could fail explosively during a short circuit, posing a severe hazard.


Choosing a breaker with an appropriate breaking capacity for the installation's prospective fault current is paramount for ensuring system safety and reliability, protecting downstream components and personnel.


Q4: Can the Siemens 5SN6563-8CN be used for home electrical systems?

Yes, the Siemens 5SN6563-8CN is highly suitable for use in residential main distribution boards. Its 63A rating and 1P+N configuration are standard for protecting the entire power supply to a dwelling.


It provides essential overcurrent protection for household circuits, safeguarding appliances and wiring from damage due to faults. The Type C tripping characteristic is also well-suited for typical home loads, which can include some inductive elements.


Ensuring correct installation by a qualified electrician is vital for safety and compliance with local electrical codes when using this breaker in a home environment.


Q5: What does the "C" in the tripping curve "Type C" refer to?

The tripping curve "C" on a circuit breaker describes its instantaneous trip current threshold. For Type C breakers, this threshold is typically between 5 to 10 times the rated current (In).


This characteristic makes Type C breakers ideal for circuits with moderate inductive loads, such as fluorescent lighting, motors, or transformers, which can draw higher currents for a brief moment upon startup. They will not trip during these normal inrush currents.


However, they still provide rapid protection against short circuits, tripping almost instantly if the current exceeds this higher threshold, thus offering a good balance for various applications.


Q6: What is the rated current of 63A and what does it mean for circuit protection?

The rated current (In) of 63A signifies the maximum continuous current the breaker can safely carry without tripping under normal operating conditions. It is the breaker's designed operational limit.


If the current in the circuit exceeds 63A for an extended period, the breaker's thermal element will heat up and eventually trip, disconnecting the power. This protects the wiring and connected devices from overheating and potential damage.


It's crucial that the breaker's rating (63A) is appropriately selected based on the current-carrying capacity of the protected circuit's wiring and the expected load.


Q7: How does this breaker integrate with other electrical components?

The Siemens 5SN6563-8CN is designed for easy integration within standard electrical distribution systems. It mounts onto a standard 35mm DIN rail, common in most modern electrical enclosures.


Its terminals are designed for secure connection with standard electrical wires, typically using screw terminals. This allows for straightforward wiring to incoming power and outgoing circuits.


As part of the Siemens ecosystem, it can be combined with other Siemens protective devices, contactors, and modular components to build complex and reliable electrical control and distribution solutions.


Q8: What safety precautions should be taken during installation?

Always de-energize the main power supply before starting any installation work to prevent electric shock. Ensure the installation environment is dry and suitable for electrical work.


Use appropriately sized conductors and ensure all connections are tight and secure to prevent loose connections, which can cause overheating and arcing. The distribution board should be properly grounded.


A qualified electrician should perform the installation to ensure compliance with all relevant electrical codes and standards, guaranteeing the safety and correct functioning of the breaker.


Q9: How do I reset the breaker after it has tripped?

After a trip event, first identify and rectify the cause of the overcurrent or short circuit. Once the fault condition is resolved, you can reset the breaker.


To reset, firmly push the breaker's toggle lever all the way up to the "ON" position. If it trips again immediately, the fault condition likely still exists and requires further investigation.


Ensure the breaker itself is not damaged. If it repeatedly trips or does not reset properly, it may need to be replaced by a qualified professional.


Q10: What are the typical environments where this breaker is used?

This breaker is commonly deployed in main distribution panels for residential buildings, providing protection for entire homes. It's also found in commercial settings, safeguarding circuits in offices, retail stores, and small businesses.


Its robust design and high breaking capacity make it suitable for light industrial applications, such as protecting circuits for smaller machinery or equipment requiring reliable fault interruption.


Essentially, any single-phase application requiring dependable overcurrent protection with a significant fault current handling capability is a prime environment for the Siemens 5SN6563-8CN.