Siemens 5SN6410-8CN High Breaking Capacity MCB 4P 10A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6410-8CN
  • HS: 85362030
Availability:In Stock
$24.05
zhongpingtech

The Siemens 5SN6410-8CN is a robust 4-pole, 10A Miniature Circuit Breaker (MCB) engineered for superior protection in demanding electrical installations. Its high breaking capacity (HBC) ensures reliable interruption of fault currents, safeguarding downstream equipment and personnel from electrical hazards. This MCB stands out with its advanced tripping characteristics, offering precise overcurrent and short-circuit protection crucial for industrial and commercial applications. Key technical parameters include a rated current of 10A, a breaking capacity of 6kA, and a voltage rating of 400V AC, making it a dependable choice for a wide range of power distribution needs.


Product Specifications


| Specification             | Value                               |

| :------------------------ | :---------------------------------- |

| Product Type              | Miniature Circuit Breaker (MCB)     |

| Manufacturer              | Siemens                             |

| Model Number              | 5SN6410-8CN                         |

| Number of Poles           | 4                                   |

| Rated Current (In)        | 10A                                 |

| Rated Breaking Capacity (Icn) | 6 kA                                |

| Rated Voltage (Ue)        | 400V AC                             |

| Tripping Characteristic   | C                                   |

| Frequency                 | 50/60 Hz                            |

| Insulation Voltage (Ui)   | 500V                                |

| Degree of Protection      | IP20                                |

| Terminal Type             | Screw Terminals                     |

| Operating Temperature     | -25°C to +45°C                      |

| Mounting Type             | DIN Rail                            |

| Compliance Standards      | IEC 60898-1, IEC 60947-2            |


Core Features & Market Positioning


The Siemens 5SN6410-8CN distinguishes itself through its exceptional reliability and adherence to stringent international safety standards, including IEC 60898-1 and IEC 60947-2. Its robust construction and high breaking capacity of 6kA make it a preferred component for applications where fault current levels can be significant, offering a critical layer of protection. The 'C' curve tripping characteristic ensures suitability for loads with moderate inrush currents, such as motors and fluorescent lighting, providing sensitive overload protection without nuisance tripping. This combination of features positions the 5SN6410-8CN as a value-driven solution for engineers and specifiers demanding dependable circuit protection in commercial and light industrial environments, differentiating it from lower-capacity or less reputable alternatives.


Key Application Scenarios


This 4-pole, 10A MCB, the Siemens 5SN6410-8CN, is ideally suited for protecting individual circuits in distribution boards within commercial buildings, such as offices, retail spaces, and educational institutions. Its application extends to protecting lighting circuits, socket outlets, and smaller motor loads where a 10A rating is appropriate and a Type C tripping curve is beneficial for handling typical inrush currents. In residential settings, it can be used for branch circuits requiring comprehensive overcurrent and short-circuit protection, particularly in larger homes or multi-unit dwellings. For light industrial use, the 5SN6410-8CN can safeguard control panels, auxiliary circuits, and smaller machinery, ensuring operational continuity and equipment safety.


Practical System Integration Guidance


Integrating the Siemens 5SN6410-8CN 4-pole MCB into existing or new electrical systems is straightforward due to its standard DIN rail mounting capability and user-friendly screw terminals. Ensure the circuit being protected does not exceed the MCB's 10A rating, and that the supply voltage does not surpass the 400V AC limit. For wiring, connect the phase conductors to terminals L1, L2, L3, and L4 (or as per specific terminal labeling for 4-pole configurations) and the neutral conductor to the remaining designated neutral terminal, observing correct polarity. Always verify that the upstream protective device (e.g., main switch) has a breaking capacity equal to or greater than the 6kA rating of the 5SN6410-8CN to ensure cascading protection coordination. Proper torque should be applied to the screw terminals to ensure secure connections and prevent overheating.


Operation and Risk Mitigation


The Siemens 5SN6410-8CN MCB operates automatically, interrupting the circuit when an overcurrent (overload or short circuit) condition is detected, indicated by the position of the toggle lever. To reset the MCB after a fault, ensure the fault condition has been cleared, then simply toggle the lever back to the 'ON' position. Understanding that the 'C' curve is designed for moderate inrush currents is vital; frequent nuisance tripping might indicate a load issue or an undersized MCB for the application. To mitigate risks, always ensure the MCB is correctly rated for the load and that the wiring is compliant with local electrical codes. Avoid resetting the MCB repeatedly without investigating the root cause of the tripping to prevent potential damage or fire hazards.


Scalability & Long-Term Value


The Siemens 5SN6410-8CN MCB offers significant long-term value through its compatibility with the broader Siemens SENTRON system portfolio. This allows for seamless integration with other protective devices, busbars, and accessories, facilitating straightforward system expansions or upgrades as electrical demands evolve. While this specific model is a standalone protective device, its design aligns with modern electrical distribution principles, ensuring it remains relevant for standard installations. For advanced integration into digital environments or IIoT platforms, it would typically be part of a larger system incorporating smart meters, intelligent gateways, or SCADA systems that monitor circuit breaker status and energy consumption at a higher level.


FAQs


Q1: What is the breaking capacity of the Siemens 5SN6410-8CN MCB?


The Siemens 5SN6410-8CN features a breaking capacity of 6 kA. This is a crucial specification for ensuring safety.


It signifies the maximum fault current the MCB can interrupt safely. Higher breaking capacity means better protection against severe short circuits.


This 6kA rating is suitable for many residential, commercial, and light industrial applications. It meets common protection requirements.


Q2: What type of loads is the Siemens 5SN6410-8CN MCB suitable for?


This MCB has a Type C tripping curve. This makes it ideal for loads with moderate inrush currents.


Examples include fluorescent lighting and small to medium-sized electric motors. It prevents nuisance tripping during startup.


It provides sensitive overload protection while accommodating typical inductive or capacitive inrush. It balances protection and operational stability.


Q3: Can the Siemens 5SN6410-8CN be used in residential electrical panels?


Yes, the Siemens 5SN6410-8CN is suitable for residential use. It provides essential circuit protection.


It is particularly useful for branch circuits requiring overcurrent and short-circuit safeguarding. Its 10A rating suits many household circuits.


Always ensure it's installed by a qualified electrician adhering to local codes. It ensures safe and reliable operation.


Q4: What does a 4-pole MCB mean for the Siemens 5SN6410-8CN?


A 4-pole MCB protects four separate electrical conductors simultaneously. It is typically used for three-phase power or single-phase systems needing neutral disconnect.


It ensures all live conductors and the neutral are switched simultaneously. This enhances safety, especially in sensitive systems.


For specific applications like 3-phase circuits or systems requiring neutral isolation, a 4-pole device offers complete control and protection. It is common in industrial settings.


Q5: How do I install the Siemens 5SN6410-8CN MCB?


Install the MCB on a standard 35mm DIN rail. Ensure secure mounting for stability and proper contact.


Connect the incoming power conductors to the appropriate terminals. Follow wiring diagrams and torque specifications for secure connections.


Always de-energize the circuit before installation and verify connections post-installation. Consult the manual for detailed instructions.


Q6: What is the rated current of the Siemens 5SN6410-8CN?


The rated current for this MCB is 10 Amperes (10A). This is the maximum continuous current it can safely handle.


It is crucial to select an MCB with a rating appropriate for the connected load's continuous current draw. Avoid overloading the circuit.


Exceeding the 10A limit may cause the MCB to trip unnecessarily or lead to overheating if the fault current is not high enough to trip it immediately. It ensures circuit integrity.


Q7: Does the Siemens 5SN6410-8CN comply with international standards?


Yes, this MCB complies with IEC 60898-1 and IEC 60947-2. These are widely recognized international standards for circuit breakers.


Compliance ensures the product meets rigorous safety and performance requirements. It guarantees reliability and interoperability.


These standards cover aspects like breaking capacity, electrical endurance, and general safety requirements for circuit protection devices. It assures quality.


Q8: What is the voltage rating of the Siemens 5SN6410-8CN MCB?


The rated voltage (Ue) for this MCB is 400V AC. This specifies the maximum AC voltage it is designed to operate at.


Ensure the supply voltage of the circuit where it is installed does not exceed 400V AC. This is essential for safe operation.


Operating outside this voltage range can lead to malfunction, reduced lifespan, or safety hazards. It must match the system's voltage.


Q9: What does the 'C' in the tripping characteristic 'C' mean?


The 'C' characteristic indicates a moderate level of inrush current tolerance. It's designed for loads that have higher starting currents than resistive loads.


This type of MCB is commonly used for inductive loads like small motors, transformers, and lighting systems. It prevents premature tripping during motor start-up.


Compared to a Type B MCB, a Type C MCB will tolerate higher transient currents before tripping, offering better performance for specific applications. It’s a balance of sensitivity.


Q10: Where can I find the official datasheet or manual for the Siemens 5SN6410-8CN?


Official datasheets and manuals are typically available on the Siemens industrial automation or product support website. Search using the exact model number.


You can often find them by searching for "Siemens 5SN6410-8CN datasheet" or "Siemens 5SN6410-8CN manual". Downloadable PDFs are usually provided.


These documents contain comprehensive technical details, installation guides, and safety information directly from the manufacturer. They are the most reliable source.

Menu