Siemens 5SU9156-7KK10 RCCB 10A 10mA 1P+N C

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SU9156-7KK10
  • HS: 8536209900
Availability:In Stock
$24.42
zhongpingtech

The Siemens 5SU9156-7KK10 is a vital component in modern electrical protection systems, offering superior safety and reliability for a wide range of applications. This Residual Current Circuit Breaker (RCCB) is engineered with advanced technology to detect and interrupt fault currents, safeguarding personnel and equipment from electric shock and fire hazards. Its compact design, robust construction, and adherence to stringent international standards make it a preferred choice for industrial, commercial, and residential installations. Key advantages include its high sensitivity to residual currents, rapid tripping response, and dependable performance even under demanding conditions.


Siemens 5SU9156-7KK10: Product Specifications


| Feature                     | Specification                               |

| :-------------------------- | :------------------------------------------ |

| Product Type                | Residual Current Circuit Breaker (RCCB)     |

| Model Number                | 5SU9156-7KK10                               |

| Rated Current (Ie)          | 10A                                         |

| Rated Residual Operating Current (IΔn) | 10mA                                        |

| Number of Poles             | 1P+N (1 Pole + Neutral)                     |

| Tripping Characteristic     | Type C                                      |

| Rated Voltage (Ue)          | 230V AC                                     |

| Rated Breaking Capacity (Icn) | 6kA                                         |

| Frequency                   | 50/60 Hz                                    |

| Terminal Type               | Screw Terminals                             |

| Mounting Type               | DIN Rail                                    |

| Operating Temperature Range | -25°C to +45°C                              |

| Protection Class            | IP20 (enclosure), IP40 (front)              |

| Compliance Standards        | IEC/EN 61008-1                              |


Core Features & Market Positioning


The Siemens 5SU9156-7KK10 distinguishes itself through its Type C tripping characteristic, which provides enhanced protection against nuisance tripping caused by inrush currents from inductive loads, such as motors and transformers, while still ensuring rapid and effective fault current detection. This makes it exceptionally well-suited for applications where temporary overcurrents are common, offering a balance between sensitivity and operational resilience. Its 10mA residual operating current provides a high level of personal protection, significantly reducing the risk of electric shock, a critical consideration in environments with increased exposure to moisture or conductive materials. Siemens' reputation for manufacturing high-quality, durable electrical components further solidifies the 5SU9156-7KK10's market position as a reliable and long-term investment for critical electrical infrastructure.


Key Application Scenarios


This 10A, 10mA, 1P+N Type C RCCB is extensively utilized in scenarios demanding precise and sensitive fault current detection. Its primary applications include protecting individual circuits in residential electrical panels, especially those powering appliances with motors like washing machines or refrigerators, where Type C tripping is advantageous. In commercial settings, it is ideal for safeguarding lighting circuits and socket outlets in offices, retail spaces, and small workshops where the risk of electric shock is a concern. For light industrial use, it provides essential protection for control circuits, small motor loads, and sensitive electronic equipment that require rapid disconnection upon detecting even small residual currents, thereby preventing damage and ensuring operational continuity.


Practical System Integration Guidance


Integrating the Siemens 5SU9156-7KK10 into an electrical system is a straightforward process, leveraging standard DIN rail mounting for quick installation. Ensure the main power supply is de-energized before commencing any work. Connect the line (input) conductors to the designated L terminal and the neutral conductor to the N terminal. The load (output) conductors are then connected to the corresponding output terminals. Proper wiring is crucial; the neutral conductor must be connected to the designated neutral terminal to ensure correct operation of the residual current sensing mechanism. Earthing connections should follow local electrical codes and standards for comprehensive system safety. Always verify connections and perform insulation resistance tests before re-energizing the circuit.


Operation and Risk Mitigation


The Siemens 5SU9156-7KK10 operates by continuously monitoring the balance of current flowing through the live and neutral conductors. If an imbalance occurs, indicative of current leakage to earth (a fault condition), the RCCB rapidly trips, interrupting the circuit. To reset the device after a trip, first identify and rectify the cause of the fault. Then, push the toggle switch fully upwards. For critical industrial operations, regular testing using a dedicated RCCB tester is paramount to confirm its operational integrity. Avoiding overloading circuits and ensuring correct wiring configuration are key to mitigating potential issues and ensuring the longevity and effectiveness of the protection provided by the 5SU9156-7KK10.


Scalability & Long-Term Value


The modular design of Siemens' electrical distribution components, including the 5SU9156-7KK10, ensures excellent compatibility with a wide array of upstream and downstream protective devices and busbar systems within the Siemens portfolio. This facilitates easy scalability and future upgrades to electrical installations. For facilities integrating modern automation and IIoT solutions, this RCCB serves as a foundational safety element. While it does not possess direct digital communication capabilities, its reliable operation and integration into smart panelboards allow for remote monitoring of circuit status via associated intelligent devices, contributing to the overall digital transformation of building and industrial management systems and ensuring long-term operational value.


Frequently Asked Questions (FAQs)


What is the primary function of the Siemens 5SU9156-7KK10 RCCB?

This device detects residual currents, offering protection against electric shock. It quickly trips the circuit when fault currents to earth are detected. This prevents dangerous situations and potential equipment damage.


It safeguards personnel and property from hazards like electrocution. The 10mA sensitivity is ideal for high-risk environments. Its function is crucial for electrical safety compliance.


The 5SU9156-7KK10 is essential for preventing fires caused by electrical faults. It provides a critical layer of safety in any electrical installation.


Can the Siemens 5SU9156-7KK10 be used for overcurrent protection?

No, this RCCB is primarily for residual current protection. It detects imbalances in current flow. It does not provide standard overcurrent or short-circuit protection.


For overcurrent protection, it must be used in conjunction with a Miniature Circuit Breaker (MCB) or fuse. The RCCB handles earth fault detection. The MCB handles overload and short circuits.


Combining an RCCB with an MCB offers comprehensive circuit protection. This setup meets advanced safety standards.


What does the '10mA' rating signify for this Siemens RCCB?

The 10mA rating indicates the device's sensitivity to leakage current. It will trip when a fault current of 10 milliamperes or more flows to earth. This is a high level of sensitivity for personal protection.


This sensitivity is crucial for preventing severe electric shocks. It ensures rapid disconnection in hazardous situations. It is ideal for areas where users might come into contact with live parts.


A 10mA RCCB is specifically recommended for protecting individuals in potentially wet environments. It offers enhanced safety compared to higher mA rated devices.


Is the Siemens 5SU9156-7KK10 suitable for motor starting currents?

Yes, the Type C tripping characteristic makes it suitable for circuits with moderate inrush currents. Motor starting currents can be significantly higher than running currents. This characteristic allows for these temporary surges without tripping.


However, the 10A rating of the device must be considered. The continuous load current should not exceed 10A. Motor size and starting characteristics are key factors.


For larger motors or frequent starts, a higher rated RCCB or specific motor protection devices might be necessary. Always consult the motor's specifications.


What is the purpose of the '1P+N' configuration in the Siemens 5SU9156-7KK10?

The 1P+N designation means the RCCB has one protected pole and one neutral pole. It switches both the live and neutral conductors simultaneously. This ensures complete isolation of the circuit.


This configuration is important for safety, especially in single-phase installations. It guarantees that the neutral conductor is also disconnected during a fault. This prevents a shock hazard if the neutral is inadvertently touched.


The 1P+N design is common for single-phase circuits where residual current protection is required. It provides comprehensive protection for the entire circuit.


How does the Type C tripping characteristic benefit applications?

Type C offers higher immunity to nuisance tripping from inductive loads. These loads, like motors or transformers, produce temporary current surges upon activation. The Type C characteristic tolerates these inrush currents.


This ensures that the circuit remains operational during normal start-up sequences. It prevents unnecessary disconnections of equipment. This is vital for maintaining productivity and preventing disruptions.


While providing this surge tolerance, Type C still offers rapid tripping for actual fault currents. It strikes a balance between operational continuity and safety protection.


What are the typical installation environments for the Siemens 5SU9156-7KL10?

This RCCB is ideal for residential installations, protecting circuits for appliances with motors. It is also used in commercial buildings for socket outlets and lighting circuits. Its versatility suits many general-purpose applications.


In light industrial settings, it can protect control panels and sensitive electronic equipment. The 10mA rating provides enhanced personal safety in all these environments. Its robust design ensures reliability.


The operating temperature range of -25°C to +45°C allows for use in a wide variety of ambient conditions. It is suitable for both indoor and protected outdoor applications.


What is the breaking capacity (Icn) of this Siemens RCCB?

The Siemens 5SU9156-7KK10 has a rated breaking capacity (Icn) of 6kA. This indicates the maximum fault current it can safely interrupt without sustaining damage. This capacity is generally sufficient for most residential and commercial final circuits.


A higher breaking capacity is typically required for main distribution boards or areas with higher potential fault levels. It is crucial to ensure the RCCB's breaking capacity matches or exceeds the prospective fault current at its installation point. This prevents catastrophic failure during a severe short circuit.


Always consult system design specifications or perform a fault current calculation if there is any doubt about the prospective fault current. Matching the Icn ensures the device performs its protective function reliably.


Where can I find the user manual or installation guide for the Siemens 5SU9156-7KK10?

The official Siemens Industry Online Support (SIOS) platform is the primary source for all technical documentation. You can typically find user manuals, installation guides, datasheets, and certificates by searching for the product model number (5SU9156-7KK10) on the SIOS website. These documents provide comprehensive details on installation, operation, and maintenance.


Alternatively, contact your authorized Siemens distributor or sales representative. They can often provide direct links or printed copies of the required documentation. Ensure you request the manual specific to your region, as standards and regulations can vary.


For immediate quick-start information, the product's packaging or label may contain essential connection diagrams and safety warnings. However, for in-depth understanding, the full manual is indispensable.


What maintenance is required for the Siemens 5SU9156-7KK10 RCCB?

Regular functional testing is the most critical maintenance. Use a dedicated RCCB test device to simulate a fault current and verify tripping. This should be performed at least annually, or more frequently in critical applications, as per local regulations.


Visually inspect the device for any signs of damage, discoloration, or loose connections. Ensure the terminals are clean and free from corrosion. Periodically check that the toggle operates freely and latches securely.


While the device itself is largely maintenance-free, the overall electrical installation it is part of requires adherence to good electrical practice. This includes ensuring correct wiring, avoiding overloading, and maintaining proper ventilation.

Menu