ABB S201M-C16 High Performance Single Pole MCB 16A

stars
  • Availability:In Stock
  • Brand:ABB
  • Model:S201M-C16
  • HS: 85362030
Availability:In Stock
$4.05
zhongpingtech

The ABB S201M-C16 is a high-performance single-pole Miniature Circuit Breaker (MCB) engineered for robust circuit protection in demanding industrial and commercial environments. This 16A device offers superior tripping characteristics and enhanced safety features, making it a critical component for safeguarding electrical installations against overloads and short circuits. Its advanced thermal-magnetic tripping mechanism ensures reliable operation across a wide temperature range, while its compact design facilitates space-efficient panel building. The S201M-C16 is designed for quick and secure installation, offering a dependable solution for various power distribution needs.


Product Specifications


| Specification              | Value                               |

| :------------------------- | :---------------------------------- |

| Product Type               | Miniature Circuit Breaker (MCB)     |

| Pole Configuration         | 1P (Single Pole)                    |

| Rated Current (In)         | 16 A                                |

| Tripping Curve             | C                                   |

| Rated Breaking Capacity    | 6 kA                                |

| Voltage Rating (Ue)        | 230/400 V AC                        |

| Frequency                  | 50/60 Hz                            |

| Ambient Temperature Range  | -25 to +55 °C                       |

| Terminal Type              | Screw Terminal                      |

| Mounting Type              | DIN Rail (35mm)                     |

| IP Protection Rating       | IP20                                |

| Housing Material           | Thermoplastic                       |

| Certifications             | CE, IEC, UL, CSA                    |


Core Features & Market Positioning


The ABB S201M-C16 distinguishes itself through its robust C-curve tripping characteristic, specifically designed to handle moderate inrush currents common in inductive loads, such as motors and transformers, without nuisance tripping. This feature is crucial for industrial applications where equipment startups can generate transient surges. Its high breaking capacity of 6 kA provides ample protection against severe fault conditions, ensuring operational safety and equipment longevity. As part of ABB's S200 series, the S201M-C16 benefits from decades of electrical protection innovation, positioning it as a reliable and trusted choice for professionals seeking dependable performance and adherence to stringent international standards.


Key Application Scenarios


The versatility of the ABB S201M-C16 makes it suitable for a broad spectrum of applications within industrial, commercial, and residential settings. It is extensively deployed in power distribution boards, control panels, and machinery enclosures to protect individual circuits from overloads and short circuits. Common scenarios include safeguarding lighting circuits, socket outlets, small motor loads, and sensitive electronic equipment. Its C-curve characteristic is particularly beneficial in manufacturing plants for protecting machinery and automation systems, where inductive loads are prevalent. Furthermore, its compliance with global standards facilitates its integration into projects requiring international certifications.


Practical System Integration Guidance


Integrating the ABB S201M-C16 into an electrical system is straightforward due to its standard DIN rail mounting capability and clearly marked terminals. Ensure the supply conductors are connected to the upper terminals (line) and the load conductors to the lower terminals (load) to guarantee correct operation of the internal mechanism. The breaker should be installed in an environment within its specified ambient temperature range of -25 to +55 °C. When wiring, use appropriate gauge conductors that match the 16A rating and ensure all connections are securely tightened to prevent overheating. Proper coordination with upstream protective devices is essential for selective protection schemes.


Operation and Risk Mitigation


Operating the ABB S201M-C16 involves simple manual actuation via the toggle lever for connection and disconnection. The lever indicates the ON/OFF status, with a clear visual separation between the two positions. In the event of an overload or short circuit, the MCB will automatically trip, interrupting the circuit to prevent damage and fire hazards. To reset the breaker after a trip, first, identify and rectify the cause of the fault, then simply push the toggle lever upwards to restore power. Never force the lever if it does not reset, as this may indicate a persistent fault condition requiring professional diagnosis. Regular inspection of terminals for signs of wear or damage is recommended for preventative maintenance.


Scalability & Long-Term Value


The ABB S200 series, to which the S201M-C16 belongs, offers excellent compatibility with a wide range of ABB's modular DIN rail devices, enabling straightforward expansion and modification of electrical installations. This inherent scalability ensures that systems can be adapted to changing power demands or the integration of new equipment without requiring a complete overhaul of the existing protective infrastructure. While the S201M-C16 is a foundational component, its reliable performance and durability contribute to the long-term value of any electrical system, reducing the likelihood of costly downtime and equipment failures. Its adherence to evolving industrial standards also supports its relevance in future system upgrades, including potential integration with smart grid technologies.


Frequently Asked Questions (FAQs)


1. What is the tripping curve of the ABB S201M-C16 MCB?


The ABB S201M-C16 features a C-curve tripping characteristic. This curve is designed for applications with moderate inrush currents. It allows for a higher inrush current compared to B or K curves.


2. What is the breaking capacity of the ABB S201M-C16?


This MCB has a rated breaking capacity of 6 kA. This means it can safely interrupt fault currents up to 6,000 amperes. It provides robust protection against severe short circuits.


3. Can the ABB S201M-C16 be used for motor protection?


Yes, the C-curve is suitable for protecting small to medium-sized motor loads. It can handle the temporary inrush current when a motor starts up. For larger motors, specific motor protection circuit breakers may be required.


4. What is the voltage rating for the ABB S201M-C16?


The S201M-C16 is rated for a voltage of 230/400 V AC. It is suitable for use in single-phase and three-phase distribution systems. Always ensure compatibility with your system voltage.


5. How do I reset the ABB S201M-C16 after it trips?


After a trip, first identify and resolve the fault. Then, simply push the toggle lever upwards to reset the breaker. Do not force the lever if it does not move freely.


6. What is the ambient temperature range for operating the S201M-C16?


The operational ambient temperature range is -25 to +55 °C. Ensure the installation environment stays within these limits for reliable performance. Extreme temperatures can affect tripping characteristics.


7. Is the ABB S201M-C16 suitable for residential use?


While primarily designed for industrial and commercial use, its features make it suitable for certain residential applications. It offers advanced protection for circuits with higher load requirements. Local electrical codes should always be consulted.


8. What type of terminal connection does the S201M-C16 use?


This MCB utilizes screw terminals for connection. Ensure the correct size of conductor is used and connections are properly tightened. This ensures a safe and reliable electrical connection.


9. Can I wire the ABB S201M-C16 in reverse?


No, wiring should be done with the line supply connected to the top terminals. The load should be connected to the bottom terminals for correct operation. Reverse wiring can compromise safety and functionality.


10. What does "16A" signify on the ABB S201M-C16?


The "16A" indicates the rated current of the circuit breaker. This is the maximum continuous current the device can carry without tripping. It protects circuits from overcurrents exceeding this value.

Menu