SIEMENS LGK16.333A27 Burner Control Unit 230V LGK16

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:LGK16.333A27
  • HS: 8416900000
Availability:In Stock
$1117.65
zhongpingtech

The Siemens LGK16.333A27 Burner Control Unit 230V LGK16 is a robust and reliable solution designed for the precise control of industrial burners. This unit offers enhanced safety features, efficient operation, and seamless integration into various combustion systems. Its core advantages lie in its advanced flame monitoring capabilities, comprehensive diagnostic functions, and high operational reliability, ensuring optimal performance and extended equipment lifespan. Key technical parameters include an operating voltage of 230V AC, suitability for single or two-stage operation, and an integrated safety shut-off time. The LGK16.333A27 is engineered for demanding industrial environments, providing critical control for boilers, furnaces, and other combustion equipment.


Product Specifications


| Feature              | Specification                       |

| :------------------- | :---------------------------------- |

| Product Type         | Burner Control Unit                 |

| Manufacturer         | Siemens                             |

| Model Number         | LGK16.333A27                        |

| Voltage              | 230V AC                             |

| Application          | Single/Two-stage burners            |

| Safety Shut-off Time | ≤ 1 s (at 100-110% of mains voltage) |

| Ambient Temperature  | -20 °C to +60 °C                    |

| Protection Class     | IP40                                |

| Max. Humidity        | 95%                                 |


Core Features & Market Positioning


The Siemens LGK16.333A27 distinguishes itself through its advanced flame detection circuitry, offering reliable performance with both oil and gas flames. Its robust design ensures longevity even in harsh industrial conditions. The unit's integrated diagnostic LEDs provide clear status indication, simplifying troubleshooting and maintenance. Positioned as a high-reliability component for critical combustion processes, the LGK16.333A27 is favored in applications where operational safety and continuous performance are paramount. Its compatibility with a wide range of burner types and its adherence to stringent safety standards cement its reputation as a leading choice in industrial burner control.


Key Application Scenarios


This Siemens burner control unit, the LGK16.333A27, is ideally suited for a variety of industrial heating applications. It finds extensive use in controlling single and two-stage burners for industrial boilers, process heaters, and thermal oxidizers. Furthermore, its robust design makes it a dependable choice for applications within the chemical processing industry and for specialized industrial drying systems. The unit's precise control capabilities also lend themselves to integration in commercial HVAC systems where reliable and safe burner operation is critical.


Practical System Integration Guidance


Integrating the Siemens LGK16.333A27 into an industrial combustion system requires careful attention to wiring and interconnections. The unit typically connects to flame detectors (UV, infrared, or flame rod), ignition transformers, fuel valves, and associated control circuits. Ensuring correct polarity and secure connections is vital for reliable operation. For optimal performance, it is recommended to follow the manufacturer's wiring diagrams precisely, paying close attention to the designated terminals for power supply, safety interlocks, and burner feedback signals. Proper grounding and shielding of control lines can prevent electromagnetic interference, enhancing system stability.


Operation and Risk Mitigation


The LGK16.333A27 operates by monitoring the flame signal and controlling the burner sequence—ignition, main flame establishment, and shutdown. In the event of flame failure or other critical system faults, the unit initiates a rapid safety shutdown sequence, de-energizing the fuel valves. This is crucial for preventing unburnt fuel accumulation and potential explosions. Users should be aware of common fault indications, such as a flashing LED indicating flame loss during operation or a steady fault light signifying an internal error or a persistent external safety circuit issue. Regular visual inspections and adherence to maintenance schedules are key risk mitigation strategies.


Scalability & Long-Term Value


While the LGK16.333A27 is a standalone control unit, its value extends through its robust and reliable design, contributing to the longevity of the overall combustion system. Its compatibility with standard industrial communication protocols (when integrated within a larger control architecture) allows for data logging and remote monitoring, supporting predictive maintenance initiatives. The unit's adherence to international safety standards ensures continued compliance and operational viability in evolving regulatory landscapes. For enhanced scalability, Siemens offers a range of integrated burner management systems that can incorporate multiple LGK units for complex applications, providing a clear upgrade path.


Frequently Asked Questions


Q1: How do I troubleshoot a flame failure on the Siemens LGK16.333A27?

A flame failure typically indicates a problem with the flame detection.

Check the flame sensor (UV probe, ionization rod) for damage or fouling.

Verify wiring integrity between the sensor, control unit, and associated components.


Q2: What is the maximum ambient temperature for the LGK16.333A27?

This burner control unit operates reliably within a specific temperature range.

The maximum specified ambient operating temperature for the LGK16.333A27 is +60 °C.

Operating outside this range can compromise performance and device longevity.


Q3: Can the Siemens LGK16.333A27 be used for gas and oil burners?

Yes, this control unit is versatile in its application.

It is designed to safely control both gas and oil burners.

Ensure the flame detection method (e.g., UV, ionization) is appropriate for the fuel type.


Q4: What does the safety shut-off time mean for the LGK16.333A27?

This is a critical safety parameter.

It defines the maximum time allowed for the burner to safely shut down after a fault is detected.

For the LGK16.333A27, this time is specified as ≤ 1 second.


Q5: How do I reset the Siemens LGK16.333A27 after a fault?

Resetting procedures are crucial for safe operation.

Typically, a reset involves cycling the power to the unit after the fault condition has been cleared.

Consult the product manual for specific reset sequences to avoid damage.


Q6: Is the LGK16.333A27 suitable for single-stage or two-stage burners?

The unit's design accommodates different burner control needs.

It is engineered to manage both single-stage and two-stage burner operations.

This flexibility makes it suitable for a wide array of combustion applications.


Q7: What is the IP rating of the Siemens LGK16.333A27?

The IP rating indicates the level of protection against environmental ingress.

The LGK16.333A27 has an IP40 protection class.

This means it is protected against solid objects larger than 1mm and has no protection against water.


Q8: How important is proper grounding for the LGK16.333A27?

Proper grounding is essential for system safety and performance.

Effective grounding helps prevent electrical shocks and protects the unit from transient voltage surges.

It also minimizes electromagnetic interference, ensuring stable burner control.


Q9: What voltage does the Siemens LGK16.333A27 require?

The control unit operates on a standard industrial power supply.

It requires an operating voltage of 230V AC.

Always ensure the power supply matches the specified voltage to prevent damage.


Q10: Where can I find the wiring diagram for the LGK16.333A27?

Accurate wiring is key to successful installation.

The official Siemens product manual for the LGK16.333A27 contains the detailed wiring diagram.

Always refer to the manufacturer's documentation for precise connection instructions.

Menu