zhongpingtech

The DANFOSS VLT Automation Drive FC-360HK75T4E20H2BXCDXXSXXXXA0BX is a high-performance 0.75kW, 3-phase AC variable speed drive designed for demanding industrial applications. This drive boasts exceptional energy efficiency, robust motor control capabilities, and a compact footprint, making it an ideal solution for optimizing processes and reducing operational costs. Its advanced features, including precise speed regulation and integrated safety functions, position it as a leading choice for diverse automation tasks. Key technical parameters include a 0.75kW power rating, 3-phase AC input at 480V, and a standard enclosure type.


Product Specifications


| Parameter               | Value                                   |

| :---------------------- | :-------------------------------------- |

| Model                   | FC-360HK75T4E20H2BXCDXXSXXXXA0BX         |

| Power                   | 0.75 kW                                 |

| Input Voltage           | 3 x 480V AC                             |

| Series                  | VLT Automation Drive FC-360             |

| Enclosure Code          | A0BX                                    |

| Control Type            | Variable Speed Drive (VSD)              |

| Motor Control           | Advanced Sensorless Vector Control      |

| Integrated Functions    | Built-in brake chopper, RS-485          |

| Protection Class        | IP20 (Standard for A0BX)                |

| Ambient Temperature     | -20°C to +50°C (derating may apply)      |

| Installation            | Wall or panel mounting                  |


Core Features & Market Positioning


The DANFOSS FC-360 stands out due to its superior motor control algorithms, particularly its advanced sensorless vector control, which ensures precise speed and torque regulation even under varying load conditions. This capability significantly enhances process stability and product quality in applications where consistent performance is critical. Furthermore, its compact design, especially the FC-360HK75T4E20H2BXCDXXSXXXXA0BX model, allows for efficient space utilization in control cabinets, a crucial factor in many industrial settings. Danfoss's reputation for reliability and longevity in the automation sector further solidifies the FC-360's market position as a dependable, long-term investment for industrial operations seeking to optimize efficiency and minimize downtime.


Key Application Scenarios


This 0.75kW VLT Automation Drive is highly versatile, finding extensive use in various industrial sectors. Its precise control makes it ideal for fan and pump applications in HVAC systems, where energy savings through variable speed operation are paramount. Conveyor systems in material handling, automated production lines in manufacturing, and processing equipment in the food and beverage industry also benefit greatly from the FC-360's ability to deliver accurate speed and torque. The drive's robust design and integrated safety features make it suitable for demanding environments and critical processes that require high reliability.


Practical System Integration Guidance


Integrating the DANFOSS FC-360HK75T4E20H2BXCDXXSXXXXA0BX into an industrial system is straightforward. The drive supports standard wiring practices for 3-phase AC power input and motor output. For communication, it features an integrated RS-485 port, enabling easy integration into Modbus RTU networks or other serial communication systems for remote monitoring and control. Commissioning involves basic parameter setup, including motor data and desired operating limits, which can be efficiently managed via the drive's local keypad or through PC-based configuration software, ensuring rapid deployment and optimal performance.


Operation and Risk Mitigation


Operating the DANFOSS VLT Automation Drive FC-360 requires adherence to general electrical safety standards. Ensure proper grounding and ventilation to prevent overheating and electrical hazards. Critical fault codes are typically displayed on the drive's interface, providing immediate insight into operational issues. For instance, common faults might relate to overcurrent, overvoltage, or motor thermal overload, each with specific diagnostic codes that assist technicians in swift troubleshooting. Understanding these codes and having the relevant manual readily available is crucial for minimizing downtime and ensuring safe operation.


Scalability & Long-Term Value


The DANFOSS FC-360 series offers a degree of scalability through its compatibility with various communication protocols and expansion options, allowing it to be integrated into larger control systems. While this specific 0.75kW model is designed for individual machine control, it can be part of a distributed control architecture. Its robust construction and Danfoss's commitment to product development ensure long-term value, with regular firmware updates and available support services to maintain optimal performance and adapt to evolving industrial automation needs, including potential integration with IIoT platforms for enhanced data analytics.


Frequently Asked Questions


What are the primary benefits of using the DANFOSS FC-360HK75T4E20H2BXCDXXSXXXXA0BX?

This drive offers significant energy savings through precise speed control. It provides advanced motor control for improved process efficiency and product quality. Its compact design also facilitates easier integration into existing control panels.


How do I connect the motor to the DANFOSS VLT Automation Drive FC-360?

Connect the motor's three phase leads to the drive's U, V, and W terminals. Ensure proper grounding of both the drive and the motor. Always consult the specific installation manual for detailed wiring diagrams and safety precautions.


What is the typical power output of the DANFOSS FC-360HK75T4E20H2BXCDXXSXXXXA0BX?

The "75" in the model number signifies a power rating of 0.75 kilowatts. This drive is designed for motors up to this capacity, providing efficient and controlled power delivery. It's crucial to match the motor's nameplate data to the drive's capabilities for optimal performance.


Can the DANFOSS FC-360 be controlled remotely?

Yes, the FC-360 series supports remote control. It features an integrated RS-485 port for Modbus RTU communication. This allows for integration into SCADA systems or other network-based control architectures for monitoring and command.


What are the common fault codes for the DANFOSS FC-360?

Common faults include overcurrent (F001), overvoltage (F002), and motor thermal overload (F003). Each fault code indicates a specific issue requiring investigation. Always refer to the user manual for a comprehensive list and troubleshooting steps.


How do I program the DANFOSS VLT Automation Drive FC-360?

Programming can be done via the drive's local keypad or using Danfoss's MCT 10 software on a PC. Basic parameter setup involves motor data, speed references, and I/O configuration. Expert configuration may involve advanced motor control tuning.


What is the input voltage requirement for this drive?

The "480V" in the model designation indicates it requires a 3-phase AC input voltage of 480 volts. It is essential to verify the local power supply voltage matches this requirement before installation. Incorrect voltage can damage the drive.


Is the DANFOSS FC-360 suitable for harsh industrial environments?

The standard "A0BX" enclosure typically offers IP20 protection, suitable for clean to moderately dusty environments. For harsher conditions, higher IP-rated enclosures or dedicated protection measures may be necessary. Consult Danfoss for environmental suitability.


What kind of motor control does this drive offer?

This drive employs advanced sensorless vector control. This technology allows for precise speed and torque regulation without the need for a motor-mounted encoder. It optimizes performance across a wide speed range.


What are the dimensions of the DANFOSS FC-360HK75T4E20H2BXCDXXSXXXXA0BX?

The compact design is a key advantage, but specific dimensions can vary slightly by enclosure. Refer to the official product datasheet for precise measurements to ensure it fits your mounting space.