The DANFOSS FC-360HK55T4E20H2BXCDXXSXXXXALBX, a 0.55kW, 1.7A three-phase 480V Variable Frequency Drive (VFD), stands as a robust automation solution engineered for demanding industrial environments. Its advanced ALBX designation signifies enhanced features for superior control and integration. This VFD excels in precise motor speed regulation, energy efficiency optimization, and seamless integration into complex automation systems, making it a pivotal component for modern manufacturing and process control. Key technical parameters include a power rating of 0.55kW, a maximum current output of 1.7A, and an operating voltage of 480V three-phase.
Product Specifications
| Parameter | Value |
| :---------------- | :----------------------------------- |
| Model | FC-360HK55T4E20H2BXCDXXSXXXXALBX |
| Power Rating | 0.55 kW |
| Full Load Current | 1.7 A |
| Input Voltage | 480 V (Three Phase) |
| Control Method | Advanced Vector Control |
| Enclosure | IP20 (Standard) |
| Filter | Integrated EMC Filter (Class A) |
| Communication | Optional Fieldbus Modules |
| Braking | Integrated DC Bus and Optional Brakes |
| Ambient Temp. | -10°C to +50°C |
Core Features & Market Positioning
The DANFOSS FC-360HK55T4E20H2BXCDXXSXXXXALBX distinguishes itself through its advanced VLT® Flux Performance™ control, ensuring exceptional motor speed and torque accuracy even under fluctuating load conditions. This technology allows for significant energy savings by precisely matching motor speed to application demands, reducing wasted power. Its robust design, featuring an integrated EMC filter and options for enhanced braking capabilities, positions it as a reliable choice for applications requiring stringent electrical noise control and dynamic stopping performance. The ALBX variant suggests enhanced features, likely including advanced diagnostics and connectivity options, differentiating it in the competitive VFD market.
Key Application Scenarios
This VFD is ideally suited for a wide array of industrial applications where precise motor control and energy efficiency are paramount. It excels in pump and fan control, optimizing flow and pressure in HVAC systems and water management. Conveyor systems, mixers, extruders, and general industrial machinery benefit from its accurate speed regulation, leading to improved product quality and reduced wear. The 480V rating makes it a strong candidate for heavy industrial settings in North America and other regions with similar grid voltages. Its robust construction also lends itself to use in environments where dust or moderate moisture may be present, provided appropriate enclosure considerations are made.
Practical System Integration Guidance
Integrating the DANFOSS FC-360HK55T4E20H2BXCDXXSXXXXALBX into existing systems is streamlined by its user-friendly interface and comprehensive documentation. Proper wiring is crucial: ensure the incoming power supply is correctly connected to L1, L2, and L3 terminals, and the motor is wired to U, V, and W. Grounding should be securely established. For optimal performance, parameter configuration should align with the specific motor and application requirements. This often involves setting motor data (e.g., rated power, voltage, frequency, current, speed) and adjusting control parameters like acceleration/deceleration times and speed limits. Utilizing optional fieldbus communication modules allows for seamless integration into SCADA or DCS systems, enabling remote monitoring and control.
Operation and Risk Mitigation
Safe operation of the DANFOSS FC-360HK55T4E20H2BXCDXXSXXXXALBX necessitates adherence to electrical safety standards and proper installation procedures. Always ensure the VFD is de-energized before performing any wiring or maintenance. The drive should be installed in a clean, dry, and well-ventilated area, away from excessive heat, dust, or corrosive substances. Common troubleshooting involves checking for fault codes displayed on the VFD panel. For instance, overcurrent faults (often indicated by specific codes) might require derating, checking motor winding integrity, or adjusting acceleration ramps. Overvoltage faults can occur during regenerative braking or power surges, potentially necessitating the use of braking resistors or adjustments to deceleration settings.
Scalability & Long-Term Value
The DANFOSS FC-360HK55T4E20H2BXCDXXSXXXXALBX offers significant long-term value through its inherent scalability and compatibility. Its modular design, particularly with the ALBX designation, often allows for the addition of optional communication cards, expanding its integration capabilities with various industrial networks such as Profibus, DeviceNet, or EtherNet/IP. This facilitates integration into Industry 4.0 initiatives and IIoT platforms, enabling advanced data analytics, predictive maintenance, and remote diagnostics. Furthermore, the VLT® platform is known for its robust firmware and continuous development, ensuring that the drive remains a relevant and efficient component for years to come, supporting upgrade paths for enhanced functionality without requiring a complete system overhaul.
Frequently Asked Questions
What are the primary benefits of the DANFOSS FC-360HK55T4E20H2BXCDXXSXXXXALBX?
This VFD offers precise motor speed control and significant energy savings. It provides enhanced torque accuracy for demanding applications.
Its robust design ensures reliable operation in industrial settings. The ALBX designation indicates advanced features for superior integration.
It minimizes mechanical stress on machinery and extends equipment lifespan. This leads to reduced maintenance costs and increased operational uptime.
How do I wire the DANFOSS FC-360HK55T4E20H2BXCDXXSXXXXALBX?
Connect the three-phase 480V power supply to terminals L1, L2, and L3. Wire the motor to terminals U, V, and W.
Ensure proper grounding to the earth terminal for safety. Follow all local electrical codes and best practices during installation.
Consult the VFD manual for specific wiring diagrams and terminal functions. Incorrect wiring can lead to damage or malfunction.
What are common fault codes for the FC-360 VFD series?
Common faults include overcurrent (F001), overvoltage (F002), and undervoltage (F003). Motor overload (F004) and heatsink overtemperature (F005) are also frequent.
These codes indicate specific operational issues requiring investigation. Refer to the product manual for detailed explanations of each code.
Troubleshooting often involves checking parameter settings, motor conditions, and the supply voltage.
Can this VFD be used for pump and fan applications?
Yes, this VFD is highly suitable for pump and fan applications. It precisely controls speed to match demand, saving energy.
Its advanced control algorithms ensure stable flow or pressure output. This minimizes wear on motors and connected equipment.
Optimized performance reduces water hammer and system vibrations. It leads to quieter operation and increased system efficiency.
What is the power and current rating of the FC-360HK55T4E20H2BXCDXXSXXXXALBX?
The VFD has a power rating of 0.55 kW. Its full load current is 1.7 A.
This makes it suitable for smaller to medium-sized motors. Always ensure the motor's nameplate data is within the VFD's capabilities.
Exceeding the current or power rating can lead to drive failure. Proper motor selection is crucial for reliable operation.
What does the ALBX designation mean on this Danfoss VFD?
The ALBX designation typically signifies specific configuration options. It often includes enhanced features or customized builds.
This may involve integrated communication protocols or special I/O configurations. It points to a product tailored for advanced automation needs.
Consult the specific product datasheet or Danfoss documentation for precise ALBX feature details. These designations can vary.
What is the operating voltage range for this VFD?
This specific model operates on a three-phase, 480V input supply. It is designed for industrial power systems common in North America.
Always ensure the incoming power matches the VFD's rated voltage. Using an incorrect voltage can cause damage or erratic operation.
Check the VFD's nameplate and manual for precise voltage tolerances. It may have a narrow operating window.
How can I optimize energy savings with this VFD?
Precisely match motor speed to the application's actual load requirements. Avoid running motors at full speed unnecessarily.
Utilize the VFD's built-in energy-saving functions and features. Enable sleep modes or low-power states when idle.
Properly size the VFD for the motor and application. Oversized VFDs can be less efficient at lower loads.
Is this VFD suitable for harsh industrial environments?
The standard FC-360 VFD typically comes with an IP20 enclosure. This offers basic protection against solid objects.
For environments with dust, moisture, or washdown requirements, an appropriate enclosure or a VFD with a higher IP rating is necessary. Proper ventilation is also critical.
Consider auxiliary cooling or mounting in a control cabinet for harsh conditions. This ensures the VFD's longevity and reliable performance.
What are the communication options for the DANFOSS FC-360HK55T4E20H2BXCDXXSXXXXALBX?
This VFD supports various optional fieldbus communication modules. Common options include Profibus, DeviceNet, and EtherNet/IP.
These modules enable seamless integration into industrial automation networks. This allows for remote control, monitoring, and diagnostics.
Verify the specific communication module compatibility with your existing control system. The ALBX designation might imply certain pre-configured communication capabilities.