The DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX is a robust 3kW (4HP) variable frequency drive (VFD) designed for demanding industrial applications. This 3-phase AC drive operates efficiently at 480V, boasting a 7.2A continuous current rating. Its ALBX designation signifies specific configuration options tailored for enhanced performance and reliability. The FC-360 series is engineered for precision motor control, energy savings, and simplified integration into complex automation systems, positioning it as a highly competitive solution in the VLT Automation Drive market.
Product Specifications
| Parameter | Value |
| :-------------------- | :------------------------------------ |
| Model Number | FC-360H3K0T4E20H2BXCDXXSXXXXALBX |
| Power Rating | 3 kW (4 HP) |
| Input Voltage | 3-Phase AC 480V |
| Output Current (Cont.)| 7.2 A |
| Enclosure Type | ALBX (Specific configuration) |
| Control Type | VLT Automation Drive |
| Frequency | 50/60 Hz |
| Dimensions (approx.) | Varies by specific enclosure |
| Weight (approx.) | Varies by specific enclosure |
Core Features & Market Positioning
The DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX stands out with its advanced control algorithms that optimize motor performance and reduce energy consumption, a critical advantage in today's cost-conscious industrial landscape. Its robust design ensures reliability in harsh environments, a key differentiator for continuous operation. The VLT Automation Drive platform offers superior flexibility and ease of integration with various automation systems, making it a preferred choice for engineers seeking efficient and dependable motor control solutions. Danfoss's reputation for quality and innovation further solidifies its market position as a leading provider of VFD technology.
Key Application Scenarios
This DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX drive is ideally suited for a wide range of industrial applications requiring precise motor speed and torque control. Common use cases include pump and fan control in HVAC systems, conveyor systems in material handling, and processing equipment in manufacturing and food & beverage industries. Its 480V, 3-phase configuration makes it a perfect fit for North American industrial power grids, enabling significant energy savings and improved process efficiency in applications where variable speed is beneficial. The drive's robust construction, indicated by the ALBX suffix, suggests suitability for environments with moderate dust or moisture.
Practical System Integration Guidance
Integrating the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX into existing systems is streamlined through its configurable parameters and communication options. For wiring, ensure the input power supply (3x 480V AC) is correctly connected to the L1, L2, and L3 terminals, and the motor is connected to U, V, and W. Grounding is essential for safety and noise reduction. Initial setup involves configuring motor data, application parameters, and control mode (e.g., V/f or vector control). Utilizing the integrated keypad and display, or advanced software tools like Danfoss's MCT 10, facilitates parameterization and commissioning, ensuring optimal drive performance and system compatibility.
Operation and Risk Mitigation
Safe operation of the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX requires adherence to electrical safety standards and proper installation procedures. Always ensure the drive is de-energized before performing any wiring or maintenance. Key operational parameters to monitor include motor temperature, load current, and voltage. Common troubleshooting involves checking for fault codes displayed on the drive, such as "Overcurrent" or "Overvoltage," which typically indicate issues with motor load, power supply, or internal drive components. Consulting the official Danfoss VLT Automation Drive manual is crucial for detailed diagnostics and corrective actions to mitigate risks and ensure longevity.
Scalability & Long-Term Value
The DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX offers excellent long-term value through its scalability and integration capabilities. It can be seamlessly incorporated into larger automation architectures, supporting various fieldbus protocols for communication with PLCs and SCADA systems. This facilitates centralized control and data acquisition, crucial for IIoT initiatives and smart factory implementations. While the FC-360 is a specific model, the broader VLT Automation Drive platform allows for system-wide standardization, simplifying maintenance and future upgrades, ensuring a cost-effective and future-proof automation solution.
FAQs
What is the primary function of the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX?
This VLT Automation Drive controls motor speed. It optimizes energy use and process efficiency. It's for 3-phase AC motors.
Its core function is variable speed control for industrial machinery. It adjusts motor output based on demand. This reduces wasted energy and mechanical stress.
The drive provides precise torque and speed regulation. This ensures consistent product quality and smoother operation. It's a key component in modern automation.
How does the "ALBX" designation affect the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX?
"ALBX" indicates a specific enclosure and configuration. This usually relates to environmental protection. It details build options for ruggedness.
This designation impacts its suitability for certain environments. It suggests protection against dust or moisture. Check specs for precise IP rating.
The ALBX suffix confirms a standard build. It ensures compatibility with common industrial needs. It is not a custom or special order variant.
What are the main advantages of using the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX drive?
Energy savings are a major benefit. It precisely matches motor speed to load. This reduces power consumption significantly.
It offers enhanced motor protection features. This extends equipment lifespan. It prevents damage from overloads or faults.
The drive provides superior process control. This leads to improved product quality. It ensures consistent performance in demanding tasks.
Can the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX be used with single-phase motors?
No, this drive is designed for 3-phase motors. It requires a 3-phase power supply. Single-phase motor use is not supported.
Using it with a single-phase motor will cause damage. The drive's internal electronics are for 3-phase operation. Always match the drive to the motor type.
If single-phase motor control is needed, a different VFD model is required. Look for VFDs specifically designed for single-phase output. Consult Danfoss documentation for alternatives.
What is the typical input voltage for this drive?
The input voltage is 480V AC. It is a 3-phase supply. This is standard for industrial settings.
This drive is engineered for robust industrial power. The 480V rating is common in North America. Ensure your power source matches this specification.
Connecting it to incorrect voltage can cause failure. Always verify power supply compatibility before installation. Refer to the product label for confirmation.
How do I reset a fault on the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX?
Faults can often be reset via the keypad. Press the "Reset" button or menu option. Ensure the underlying issue is resolved first.
Some critical faults require power cycling. Turn off the main power supply. Wait for a minute, then restore power.
Persistent faults may need professional diagnosis. Consult the VLT Automation Drive manual. Contact Danfoss support for complex issues.
What kind of motor is compatible with this drive?
This drive is compatible with 3-phase AC induction motors. It supports standard squirrel cage motors. It's designed for 480V rated motors.
The drive's control algorithms optimize performance. It works well with standard industrial motors. Ensure the motor's power and current ratings match.
It is not suitable for DC motors or servo motors. Specific motor types require specialized drives. Always verify motor compatibility with the drive.
What are the key parameters to set during commissioning?
Motor data is crucial. Enter rated voltage, current, and frequency. Also, set motor poles and speed.
Application parameters are next. Configure acceleration/deceleration times. Set speed limits and control modes.
Basic safety parameters are important. Define overload protection levels. Set analog input/output scaling if used.
Does the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXALBX support communication protocols?
Yes, it supports various fieldbus protocols. Options often include Profibus, DeviceNet, and EtherNet/IP. These enable integration with PLCs.
Communication modules may be required. These are often optional add-ons. Check the specific drive configuration for included options.
These protocols allow for remote monitoring and control. They are essential for modern automation systems. They facilitate data exchange and diagnostics.
What is the current rating of this drive?
The continuous current rating is 7.2 Amps. This is for normal operating conditions. It is crucial for motor selection.
This rating determines the maximum motor size. Ensure your motor's full load amperage is below this. It prevents drive overload.