Siemens 3RT7017-1AN22 SIRIUS Motor Starting Contactor 200VAC 12A 3NO

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3RT7017-1AN22
  • HS: 85364900
Availability:In Stock
$6.75
zhongpingtech

The Siemens 3RT7017-1AN22 SIRIUS motor starting contactor is engineered for robust and reliable motor control in demanding industrial environments. This 200VAC, 12A, 3NO contactor offers superior operational longevity, enhanced safety features, and seamless integration within the broader SIRIUS innovation ecosystem. Its compact design and high switching capacity make it an ideal solution for a wide array of motor starting applications, from pump and fan control to conveyor systems and machine tools. The 3RT7017-1AN22 distinguishes itself through its advanced arc-quenching technology and robust construction, ensuring consistent performance and minimizing downtime.


Product Specifications


| Feature             | Specification                               |

| :------------------ | :------------------------------------------ |

| Product Type        | Motor Starting Contactor                    |

| Series              | SIRIUS                                      |

| Model Number        | 3RT7017-1AN22                               |

| Coil Voltage        | 200VAC                                      |

| Rated Operational Current (AC-3) | 12A                                         |

| Number of Normally Open (NO) Contacts | 3                                           |

| Auxiliary Contacts  | Not specified (standard configuration)      |

| Enclosure Type      | Typically requires separate enclosure       |

| Mounting Type       | DIN Rail, Screw mounting                    |

| Operating Temperature | -25 to +60 °C                               |

| Protection Class    | IP20 (terminal area)                        |

| Compliance Standards | IEC, UL, CSA                                |


Core Features & Market Positioning


The Siemens 3RT7017-1AN22 SIRIUS contactor stands out in the competitive industrial automation landscape due to its inherent reliability and advanced features. Its primary advantage lies in the SIRIUS innovation system, which emphasizes modularity, connectivity, and enhanced diagnostics. This specific model leverages Siemens' proven contactor technology, ensuring a long mechanical and electrical lifespan even under frequent switching cycles. The robust design minimizes contact wear and tear, translating to reduced maintenance costs and increased operational uptime for critical machinery. Furthermore, its compatibility with other SIRIUS components, such as overload relays and circuit breakers, simplifies system design and enhances overall protection coordination, positioning it as a preferred choice for engineers seeking dependable and integrated motor control solutions.


Key Application Scenarios


The Siemens 3RT7017-1AN22 is exceptionally well-suited for controlling squirrel-cage motors in various industrial sectors. Common applications include starting and stopping pumps in water treatment facilities and HVAC systems, where reliable operation is paramount. It's also extensively used in manufacturing for actuating conveyor belts, fans, and processing machinery on production lines. The 12A rating and 3NO configuration are ideal for general-purpose motor control up to 7.5 kW at 400V. Its versatility makes it a staple in panel building and machine tool manufacturing, where consistent and safe motor operation is a fundamental requirement for productivity and equipment longevity.


Practical System Integration Guidance


Integrating the Siemens 3RT7017-1AN22 into existing control systems is straightforward, thanks to its standardized design and the broader SIRIUS ecosystem. For secure installation, it is typically mounted on a 35mm DIN rail or directly onto a backplate using screw terminals. Wiring involves connecting the power terminals (L1, L2, L3 and T1, T2, T3) to the motor and power supply, and the control circuit terminals (A1, A2) to the command source, such as a push-button or PLC output. It's crucial to ensure the control circuit voltage precisely matches the specified 200VAC coil rating to prevent malfunction or damage. For systems requiring overload protection, the 3RT7017-1AN22 is designed to be paired with compatible SIRIUS thermal overload relays or electronic motor protection devices, which can be mounted directly below or attached alongside the contactor, forming a compact and highly effective motor feeder unit.


Operation and Risk Mitigation


Proper operation of the Siemens 3RT7017-1AN22 ensures safety and longevity. Users must always adhere to the specified coil voltage (200VAC) to prevent premature coil failure or contact welding. The internal arc-quenching system is designed to safely extinguish electrical arcs generated during switching, but it's vital to ensure adequate ventilation and avoid overloading the contactor beyond its AC-3 rating. In the event of a fault, such as a short circuit or overload, the associated protective devices (e.g., overload relays, circuit breakers) should initiate a shutdown. Common troubleshooting steps involve verifying control voltage, checking for mechanical obstructions, and inspecting contactor terminals for signs of wear or corrosion. Always disconnect power before performing any maintenance or inspection to mitigate electrical hazards.


Scalability & Long-Term Value


The Siemens 3RT7017-1AN22 offers significant scalability and long-term value within the intelligent SIRIUS innovation system. Its modular design allows for easy addition of auxiliary contact blocks (front or side-mounted) to expand control and signaling capabilities, enabling more complex logic and monitoring. This adaptability ensures that as system requirements evolve, the contactor can remain a viable component without necessitating a complete overhaul. Furthermore, its seamless integration with modern industrial control platforms, including PLCs and SCADA systems, supports the transition towards digitalized operations and the Industrial Internet of Things (IIoT). This compatibility facilitates data acquisition for predictive maintenance and performance optimization, securing its value well into the future of smart manufacturing.


FAQs


1. What is the maximum motor size this contactor can control?

This contactor, the Siemens 3RT7017-1AN22, is rated for 12A under AC-3 duty. This typically translates to controlling standard squirrel-cage motors up to approximately 7.5 kW or 10 horsepower at 400V.


Always verify the specific motor's full load current and starting characteristics against the contactor's AC-3 rating to ensure proper application. Oversizing or undersizing can lead to premature failure or safety hazards.


Consulting the Siemens SIRIUS catalog or application guidelines provides detailed motor sizing charts for various voltages and motor types.


2. Can I use a different voltage for the coil of the 3RT7017-1AN22?

No, the Siemens 3RT7017-1AN22 is specifically designed for a 200VAC coil voltage. Using a different voltage will likely cause malfunction or permanent damage to the coil.


Ensure your control circuit provides a stable 200VAC supply to the A1 and A2 terminals of the contactor. Deviations can lead to unreliable switching or failure to energize/de-energize.


Always double-check the coil voltage designation on the contactor label against the available power supply in your control panel.


3. What type of overload protection is recommended for this contactor?

The Siemens 3RT7017-1AN22 is designed to be paired with compatible SIRIUS thermal overload relays or electronic motor protection devices. These provide essential overcurrent protection for the motor.


Direct mounting of a suitable overload relay beneath the contactor is a common and efficient method for creating a complete motor feeder. Ensure the overload relay's current setting range matches the motor's requirements.


Select an overload relay that offers features like manual/automatic reset, phase-loss sensitivity, and adjustable trip classes for comprehensive motor safeguarding.


4. How do I wire the Siemens 3RT7017-1AN22 for a simple motor start/stop circuit?

Connect the main power supply (L1, L2, L3) to the top terminals (T1, T2, T3) and the motor leads to the bottom terminals (T1, T2, T3). For the coil control, connect the 200VAC supply to terminal A1 and the return to A2.


Use momentary pushbuttons for start (normally open) and stop (normally closed) wired in parallel and in series with the contactor coil, often incorporating a holding contact from the contactor itself.


Ensure all connections are tight and follow local electrical codes and safety standards. Proper wiring is critical for both functionality and safety.


5. What does "3NO" mean in the product description?

"3NO" signifies that the Siemens 3RT7017-1AN22 contactor has three "Normally Open" auxiliary contacts. These contacts are closed when the coil is energized.


These normally open contacts are primarily used for signaling or interlocking purposes within the control circuit. They can indicate that the motor is running or enable other devices when the contactor is active.


While this model has 3NO main power poles, additional auxiliary contacts (normally open or normally closed) can often be added to the front or side of the unit for expanded control logic.


6. Is this contactor suitable for frequent switching applications?

Yes, the Siemens 3RT7017-1AN22 SIRIUS contactor is built for industrial use and offers a high electrical switching life, making it suitable for frequent operations. Its robust construction and arc-quenching technology contribute to its durability.


However, the actual lifespan depends on factors like load current, switching frequency, and environmental conditions. For very high-cycle applications, it's always advisable to consult the detailed technical data for mechanical and electrical endurance.


Regular maintenance and proper installation according to specifications will maximize its operational longevity in demanding scenarios.


7. What are the dimensions of the Siemens 3RT7017-1AN22?

While exact dimensions can vary slightly with accessories, the Siemens 3RT7017-1AN22 typically has a compact footprint suitable for standard control panels. Its width is designed to fit standard DIN rail widths.


For precise measurements, refer to the official Siemens SIRIUS 3RT catalog or technical datasheet for the specific model. This will include height, depth, and mounting hole details.


Knowing the precise dimensions is crucial for panel layout and ensuring adequate space for wiring and ventilation.


8. Can this contactor be used in hazardous environments?

The standard Siemens 3RT7017-1AN22 is designed for general industrial environments and is not inherently explosion-proof or intrinsically safe for hazardous locations (e.g., Zone 1, Zone 2).


For hazardous environments, specialized ATEX-certified or equivalent contactors are required. These feature enhanced sealing and construction to prevent ignition sources.


Always consult safety regulations and select components specifically rated for the hazardous area classification of your installation.


9. What is the role of the SIRIUS innovation system?

The SIRIUS innovation system represents Siemens' integrated approach to industrial control and protection devices. It emphasizes modularity, connectivity, and digital integration for enhanced efficiency and safety.


Components within the SIRIUS system, like the 3RT7017-1AN22, are designed to work seamlessly together, simplifying engineering, installation, and diagnostics. This includes features like easy add-on auxiliary contacts and communication interfaces.


This system facilitates the transition to Industry 4.0 by enabling data exchange and remote monitoring, enhancing the overall intelligence and efficiency of motor control applications.


10. How do I troubleshoot a Siemens 3RT7017-1AN22 that is not energizing?

First, verify that the control voltage supply (200VAC) is correctly applied to the A1 and A2 terminals and that the control circuit (pushbuttons, relays) is functioning. Ensure the stop command is released.


Check for any interlocks or safety circuits that might be preventing the contactor from energizing. Inspect wiring for loose connections or breaks.


If the coil itself is suspected faulty, a continuity test can be performed (with power off), or the coil resistance can be measured against specifications.

Menu