Siemens 3RT7026-1AN25 SIRIUS Industrial High Current Contactor 200VAC 25A 3NO

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3RT7026-1AN25
  • HS: 85364900
Availability:In Stock
$10.67
zhongpingtech

The Siemens 3RT7026-1AN25 SIRIUS industrial high current contactor stands as a robust solution for demanding power control applications, boasting a 200VAC coil voltage and a substantial 25A switching capacity with 3 normally open (NO) poles. This device exemplifies Siemens' commitment to reliability and performance in industrial automation. Its core advantages lie in its high switching capability, ensuring dependable operation even under heavy loads, and its inherent safety features, crucial for industrial environments. The technical parameters highlight its suitability for a wide range of motor control and power switching tasks.


Product Specifications


| Feature             | Specification                               |

| :------------------ | :------------------------------------------ |

| Product Type        | SIRIUS Industrial Contactor                 |

| Model Number        | 3RT7026-1AN25                               |

| Coil Voltage        | 200 VAC                                     |

| Rated Current (AC-3)| 25 A                                        |

| Number of NO Poles  | 3                                           |

| Auxiliary Contacts  | 1 NO (integrated)                           |

| Mounting            | DIN rail or screw mounting                  |

| Protection Rating   | IP20                                        |

| Standards           | IEC 60947-4-1, VDE 0660                       |

| Dimensions (H x W x D)| Approx. 98 x 45 x 116 mm (without accessory)|


Core Features & Market Positioning


The Siemens 3RT7026-1AN25 differentiates itself in the industrial contactor market through its superior durability and Siemens' established SIRIUS ecosystem. Its robust construction ensures a long operational lifespan, a critical factor for minimizing downtime in continuous industrial processes. The 25A rating makes it a versatile choice for medium-duty motor control and power distribution. Furthermore, its integration capabilities within the broader SIRIUS family offer seamless compatibility with other Siemens automation components, simplifying system design and expansion. This positions the 3RT7026-1AN25 as a reliable, high-performance component for electrical engineers and system integrators seeking proven quality.


Key Application Scenarios


This high current contactor is ideally suited for a variety of industrial applications where reliable switching of power circuits is paramount. Common use cases include the direct on/off control of medium-sized three-phase motors in manufacturing plants, pumps in water treatment facilities, and fans in HVAC systems. It also finds application in general power switching, load shedding, and as a main switching device in control panels. Industries such as manufacturing, building automation, and process control frequently rely on contactors like the Siemens 3RT7026-1AN25 for their core power management functions.


Practical System Integration Guidance


Integrating the Siemens 3RT7026-1AN25 into an industrial control system is a straightforward process, leveraging standard electrical practices. The unit is designed for both DIN rail and screw mounting, offering flexibility in panel layout. Wiring involves connecting the main power conductors to the load terminals and the coil terminals to the control circuit. The integrated 1 NO auxiliary contact can be utilized for control feedback, such as indicating the contactor's status to a PLC. Ensuring correct coil voltage (200VAC) is critical for proper operation. When incorporating it into PLC-based systems, the auxiliary contact can be wired as an input to monitor the contacor's state.


Operation and Risk Mitigation


Safe operation of the Siemens 3RT7026-1AN25 relies on adherence to electrical safety standards and proper installation. It is imperative to de-energize the system before performing any wiring or maintenance. The contactor's IP20 protection rating indicates it is protected against solid objects greater than 12.5mm but not against water, necessitating installation within an enclosure to prevent contact with live parts. Overloading beyond the 25A rating can lead to premature failure and potential safety hazards. Regular inspection of wiring and terminals for signs of wear or heat is recommended to mitigate risks.


Scalability & Long-Term Value


The Siemens 3RT7026-1AN25 offers significant long-term value through its compatibility within the extensive SIRIUS modular system. This allows for easy integration with other SIRIUS components, such as overload relays, soft starters, and communication modules, enabling scalable and sophisticated automation solutions. As industrial facilities adopt Industry 4.0 principles, this contactor can be part of a system that leverages digital twins and predictive maintenance, enhancing overall operational efficiency and longevity. Its robust design ensures it remains a dependable component even as control systems evolve.


Frequently Asked Questions (FAQs)


What is the primary function of the Siemens 3RT7026-1AN25?

This device serves as an industrial high current contactor, primarily used for switching power circuits. It is designed to control electric motors and other high-power loads reliably. Its robust design ensures durability in demanding industrial settings.


It facilitates the on/off control of circuits, acting as an electrically operated switch. The 25A rating signifies its capacity for handling significant current loads. This makes it suitable for applications requiring substantial power switching.


The contactor's 3 normally open poles are ideal for managing three-phase power supplies commonly used in motor applications. It ensures safe and efficient power distribution.


Can the Siemens 3RT7026-1AN25 be used for DC applications?

The Siemens 3RT7026-1AN25 is primarily designed and rated for AC (Alternating Current) applications. Its specifications, including the 200VAC coil voltage and AC-3 rating, confirm its suitability for AC circuits.


Using this contactor in DC (Direct Current) circuits is generally not recommended without specific modifications or specialized versions. DC switching presents different arc quenching challenges compared to AC.


For DC applications, it is essential to consult Siemens' product documentation or choose a contactor specifically engineered for DC switching requirements to ensure safety and proper function.


What type of overload protection is recommended for the 3RT7026-1AN25?

For optimal protection and longevity, it is highly recommended to pair the 3RT7026-1AN25 with a compatible Siemens SIRIUS 3RU overload relay. These relays are specifically designed to work with SIRIUS contactors and offer adjustable thermal or electronic overload protection.


The overload relay monitors the current drawn by the motor or load. If the current exceeds a safe limit for a sustained period, it trips and opens the control circuit, de-energizing the contactor and preventing motor damage.


Selecting the correct overload relay with an appropriate current setting range is crucial. This ensures the protection is precisely matched to the motor's or load's requirements, preventing nuisance tripping while safeguarding against serious faults.


How do I wire the auxiliary contact on the Siemens 3RT7026-1AN25?

The Siemens 3RT7026-1AN25 comes with an integrated auxiliary contact, typically a 1 NO (normally open) type. This contact can be wired into your control circuitry to provide status feedback.


For example, the NO auxiliary contact closes when the main contactor coil is energized and the main power contacts are closed. This signal can be sent to a PLC input to indicate that the load is active or that the contactor has picked up.


Wiring involves connecting your control voltage source to one terminal of the auxiliary contact and the other terminal to your desired control input (e.g., PLC input). Ensure the control voltage is within the auxiliary contact's rating.


What is the expected lifespan of the Siemens 3RT7026-1AN25 under normal operating conditions?

The lifespan of the Siemens 3RT7026-1AN25 is influenced by several factors, including the switching frequency, load conditions, and environmental factors. Siemens SIRIUS components are engineered for high endurance and reliability.


Under typical industrial operating conditions, with loads within its rated capacity and standard switching cycles, this contactor can provide millions of switching operations. This makes it a long-term investment for industrial automation.


Regular maintenance, proper installation, and operation within specified parameters are key to maximizing its operational life. Avoiding overload conditions and ensuring clean power supply are critical.


Can this contactor be used in environments with high ambient temperatures?

The Siemens 3RT7026-1AN25 has specific operating temperature ranges. It is typically designed for ambient temperatures up to 60°C (140°F), with derating for higher temperatures.


Operating the contactor outside its specified ambient temperature range can significantly impact its performance and lifespan. High temperatures can affect coil operation and contact resistance.


For applications with elevated ambient temperatures, it is crucial to consult the product's datasheet for derating guidelines or consider alternative contactors designed for extreme environments to ensure reliable operation.


What does the "200VAC" coil voltage signify for the Siemens 3RT7026-1AN25?

The "200VAC" designation refers to the voltage required to energize the coil of the Siemens 3RT7026-1AN25 contactor. This coil, when energized, generates a magnetic field that closes the main power contacts.


This specific coil voltage of 200VAC dictates that the control circuit supplying power to the contactor must provide a stable 200-volt alternating current. Using a different voltage can lead to malfunction or damage.


It is imperative to match the control voltage source precisely to the specified coil voltage for correct operation and to prevent premature wear or failure of the contactor.


How does the 3NO configuration affect its application?

The "3NO" in the product name signifies that the Siemens 3RT7026-1AN25 has three "Normally Open" main power poles. Each pole acts as an independent switch that is open when the contactor coil is de-energized.


When the 200VAC coil is energized, all three NO poles close simultaneously, establishing a connection for the power conductors. This configuration is ideal for controlling three-phase loads, such as motors, where all three phases must be switched together.


This setup ensures that the entire three-phase circuit is connected or disconnected in unison, providing safe and effective control for balanced three-phase power applications.


Is the Siemens 3RT7026-1AN25 suitable for frequent switching applications?

Yes, the Siemens 3RT7026-1AN25 is engineered for industrial environments and is designed to handle frequent switching operations. Its robust construction and quality materials contribute to its high endurance.


The AC-3 utilization category, often associated with motor control, indicates its suitability for switching motor circuits where starting currents are higher than running currents. This implies it can handle the stresses of repeated engagement and disengagement.


However, extremely high switching frequencies (e.g., hundreds of times per minute) might require specialized contactors or solid-state relays depending on the exact application demands and desired lifespan.


What are the typical troubleshooting steps if the Siemens 3RT7026-1AN25 fails to operate?

Begin by verifying that the control circuit is supplying the correct coil voltage (200VAC) to the contactor. Check for any loose wiring connections at the coil terminals.


Inspect the main power terminals for any signs of overheating or damage, which could indicate an overload condition. Ensure the surrounding environment is within the operational temperature limits and free from excessive dust or moisture.


If the coil is receiving the correct voltage and the contactor still does not engage, there might be an internal fault with the coil or the magnetic mechanism. In such cases, replacement of the contactor might be necessary after consulting further diagnostics.

Menu