Delta DVP-F2DA 2-channel Analog Signal Output Module

stars
  • Availability:In Stock
  • Brand:DELTA
  • Model:DVP-F2DA
  • HS: 8538900000
Availability:In Stock
$36.23
zhongpingtech

The Delta DVP-F2DA 2-channel Analog Signal Output Module stands as a critical component for industrial automation, offering precise control over analog devices. This module is engineered to provide reliable and high-fidelity analog outputs, ensuring seamless integration into sophisticated control systems. Its core advantages lie in its dual-channel capability, high resolution, and robust design, making it an ideal choice for applications demanding granular analog signal generation. Key technical parameters include its voltage and current output capabilities, signal accuracy, and operating environmental specifications, all contributing to its performance in demanding industrial settings.


Product Specifications


| Feature                | Specification                                   |

| :--------------------- | :---------------------------------------------- |

| Output Channels        | 2-channel                                       |

| Output Type            | Voltage/Current (Selectable per channel)        |

| Output Range (Voltage) | ±10V                                            |

| Output Range (Current) | 0-20mA / 4-20mA                                 |

| Resolution             | 16-bit (per channel)                            |

| Accuracy               | ±0.5% of full scale                            |

| Response Time          | < 2ms                                           |

| Isolation              | Channel-to-system isolation                     |

| Power Consumption      | 5VDC, < 50mA (excluding load)                  |

| Operating Temperature  | 0°C to 55°C                                     |

| Dimensions (H x W x D) | 90mm x 60mm x 35mm                              |

| Mounting               | DIN rail                                        |


Core Features & Market Positioning


The Delta DVP-F2DA distinguishes itself in the market through its exceptional 16-bit resolution per channel, offering superior precision in analog signal generation compared to standard 12-bit modules. This high resolution translates directly into more accurate control of actuators, variable speed drives, and other analog-controlled equipment, reducing process variability and enhancing product quality. Its dual-channel configuration provides cost-effectiveness and space-saving advantages by consolidating two independent analog outputs within a single module, a significant benefit for panel builders and system integrators working with limited space and budgets. The module's selectable voltage and current output ranges offer remarkable flexibility, allowing it to interface with a wide array of field devices without requiring specialized wiring or additional signal conditioners.


Key Application Scenarios


In process control industries, the Delta DVP-F2DA is pivotal for modulating control valves, managing pump speeds, and regulating flow rates with exceptional accuracy. Its ability to output precise voltage or current signals makes it suitable for applications such as precise temperature control in HVAC systems or maintaining consistent pressure in manufacturing lines. Furthermore, in machine automation, this module enables fine-tuned control of servo motors and robotic end-effectors, ensuring smooth movements and accurate positioning critical for assembly and packaging operations. The module's reliability also lends itself to demanding environments found in food and beverage processing or chemical manufacturing where consistent analog output is paramount for product consistency and safety.


Practical System Integration Guidance


Integrating the Delta DVP-F2DA into a Delta DVP PLC system is streamlined due to its direct compatibility with the DVP series. Installation typically involves snapping the module onto a standard 35mm DIN rail within the PLC rack and connecting it to the PLC's backplane via the designated connector. Wiring of the analog outputs requires careful attention to terminal assignments for voltage (e.g., V+, V-, COM) or current (e.g., I+, COM) depending on the selected output mode. In programming, users will access the module's data registers via specific DVP instructions, such as the `DMOV` or `MOV` instructions, to write desired analog output values. For example, to set the first channel to 50% of its range (e.g., 5V for ±10V or 12mA for 0-20mA), a corresponding 16-bit integer value representing this percentage would be written to the designated output register. Configuration of the output type (voltage/current) and range is typically done through the PLC's programming software or via specific hardware jumpers on the module itself, depending on the revision.


Operation and Risk Mitigation


Safe operation of the Delta DVP-F2DA necessitates adherence to electrical safety standards and proper grounding procedures. Ensure all power and signal wiring is correctly terminated to prevent short circuits or overvoltage conditions that could damage the module or connected devices. The module's internal isolation between channels and the system helps mitigate noise interference and protects the PLC from potential ground loops, but proper system grounding is still crucial. Troubleshooting often involves checking the PLC program logic, verifying wiring connections, and confirming that the correct output type and range are configured. Fault indicators on the module or within the PLC's diagnostic registers can help identify issues; however, specific error codes for this analog output module are typically related to configuration errors or communication timeouts rather than internal hardware failures, assuming proper installation.


Scalability & Long-Term Value


The Delta DVP-F2DA is designed for seamless integration within the broader Delta DVP PLC ecosystem, offering excellent scalability. Its compatibility with various DVP series PLCs means that systems can be expanded by simply adding more analog output modules or other specialized I/O modules as application requirements grow. This modular approach ensures that existing investments in Delta control hardware are protected, allowing for phased upgrades and system enhancements without a complete platform overhaul. The module's robust design and Delta's reputation for industrial reliability contribute to its long-term value, ensuring consistent performance and minimizing downtime over the lifespan of the automation system. Furthermore, as industries move towards Industry 4.0, the analog signals generated by the DVP-F2DA can be readily digitized and integrated into SCADA or IIoT platforms for advanced data analytics and remote monitoring, future-proofing its utility.


---


Frequently Asked Questions (FAQs)


1. What is the maximum output current of the Delta DVP-F2DA?


The Delta DVP-F2DA supports an analog output range of 0-20mA or 4-20mA.

This current output is configurable per channel, offering flexibility for various industrial loads.

Ensure the load resistance is within the module's specified limits for optimal performance.


2. Can the Delta DVP-F2DA be used with non-Delta PLCs?


While designed for Delta DVP PLCs, its standard analog outputs can interface with other controllers.

Careful consideration of voltage/current signal compatibility and wiring is essential.

Refer to the PLC's I/O specifications for successful integration with third-party systems.


3. How do I configure the output type (voltage or current) on the DVP-F2DA?


Configuration is typically done via software in the PLC programming environment.

Some revisions may also have physical jumpers on the module for mode selection.

Always consult the official Delta DVP-F2DA user manual for precise instructions.


4. What is the significance of the 16-bit resolution for the DVP-F2DA?


16-bit resolution means the output signal is divided into 65,536 discrete levels.

This allows for much finer control over analog devices compared to lower resolutions.

It leads to improved accuracy and repeatability in automated processes.


5. What are the typical applications for a 2-channel analog output module?


Controlling variable speed drives for pumps and fans is common.

Modulating control valves for flow, temperature, or pressure regulation.

Driving analog indicators or meters in control panels.


6. Does the Delta DVP-F2DA offer channel-to-channel isolation?


Yes, the module provides isolation between its analog output channels.

It also offers isolation from the PLC system's internal circuitry.

This enhances signal integrity and protects against ground loop issues.


7. What voltage levels can the DVP-F2DA output?


The module supports an analog output range of ±10V.

This bipolar output is useful for applications requiring both positive and negative signal control.

Proper wiring of V+ and V- terminals is crucial for correct operation.


8. How is the Delta DVP-F2DA mounted in an industrial panel?


The module is designed for DIN rail mounting.

It snaps onto a standard 35mm wide DIN rail typically found in control cabinets.

Ensure adequate ventilation around the module and other components.


9. What happens if the analog output signal is incorrect?


Verify the PLC program logic and the data written to the output registers.

Check the wiring connections to the module and the connected device.

Confirm the output type (V/I) and range configuration matches the application.


10. Can this module integrate with IIoT platforms?


Yes, the analog signals can be read by the PLC and transmitted to IIoT platforms.

This requires additional networking hardware or software on the PLC side.

It enables remote monitoring, data logging, and advanced analytics.

Menu