OULU EV510A-0037G/0055P-T4 Heavy Duty VFD Frequency Converter 8.5A 5.5kW

stars
  • Availability:In Stock
  • Brand: OULU
  • Model: EV510A-0037G/0055P-T4
  • HS: 8504409999
Availability:In Stock
$130.00
zhongpingtech

The OULU EV510A-0037G/0055P-T4 Heavy Duty VFD Frequency Converter stands as a robust solution for variable speed drive applications, delivering precise motor control and significant energy savings. This 5.5kW, 8.5A unit is engineered for demanding industrial environments, offering advanced features designed for reliability and performance. Its key advantages lie in its high overload capability, comprehensive protection functions, and flexible control modes, positioning it as a competitive choice for a wide range of machinery.


Product Specifications


| Parameter             | Value                                  |

| :-------------------- | :------------------------------------- |

| Model                 | EV510A-0037G/0055P-T4                  |

| Rated Power           | 5.5 kW                                 |

| Rated Current         | 8.5 A                                  |

| Input Voltage         | Three-phase 380-480V                   |

| Output Frequency      | 0-400 Hz                               |

| Control Method        | V/f control, Vector control (optional) |

| Overload Capacity     | 150% for 60 seconds, 120% for 120 seconds |

| Protection Features   | Over-voltage, Under-voltage, Overload, Over-temperature, Short-circuit |

| Dimensions (H x W x D) | (Specific dimensions would be provided here if available) |

| Mounting Type         | Wall-mounted                           |


Core Features & Market Positioning


The OULU EV510A-0037G/0055P-T4 distinguishes itself through its robust heavy-duty design, which ensures reliable operation under challenging conditions. Its advanced V/f control algorithm provides excellent speed regulation and torque performance, crucial for applications demanding consistent output. Furthermore, the unit's integrated comprehensive protection features significantly reduce the risk of equipment damage and downtime, contributing to a lower total cost of ownership. This combination of durability, performance, and protective capabilities positions the OULU EV510A-0037G/0055P-T4 as a superior option in industrial automation markets seeking dependable variable frequency drives.


Key Application Scenarios


This heavy-duty VFD is ideally suited for a multitude of industrial applications. It excels in controlling centrifugal fans and pumps, where its precise speed adjustment leads to substantial energy savings and optimized performance. Conveyor systems, extruders, and machine tools also benefit from the OULU EV510A-0037G/0055P-T4's stable torque output and overload capacity, ensuring smooth and continuous operation even under heavy loads. Industries such as manufacturing, material handling, water treatment, and packaging frequently deploy this type of converter to enhance efficiency and control precision.


Practical System Integration Guidance


Integrating the OULU EV510A-0037G/0055P-T4 into existing systems is streamlined by its user-friendly interface and standard mounting design. Proper wiring is essential for optimal performance and safety; ensure the input power supply conforms to the specified three-phase voltage (380-480V) and that all connections are secure. For motor connections, follow the unit's terminal designations meticulously, paying attention to grounding. Parameter programming, accessible via the front panel keypad or optional communication modules, allows for customization of speed references, acceleration/deceleration times, and protective settings to match specific application requirements.


Operation and Risk Mitigation


Safe operation of the OULU EV510A-0037G/0055P-T4 mandates adherence to electrical safety standards and the product's operational manual. Prior to commissioning, verify that the motor's nameplate data is correctly entered into the VFD parameters. During operation, monitor for any abnormal sounds or temperatures. Common fault codes, such as E01 (Over-voltage) or E03 (Over-current), typically indicate issues with the power supply, motor, or load conditions, requiring prompt investigation. Implementing regular maintenance checks, including cleaning of ventilation openings, will further mitigate operational risks and extend the lifespan of the unit.


Scalability & Long-Term Value


The OULU EV510A-0037G/0055P-T4 offers significant long-term value through its robust construction and potential for integration into advanced control architectures. While this specific model focuses on core VFD functionality, its underlying platform may support optional communication cards, allowing for seamless integration with industrial networks like Modbus, Profibus, or Ethernet/IP. This facilitates centralized control and monitoring within an Industrial Internet of Things (IIoT) ecosystem, enabling predictive maintenance and operational optimization. The inherent reliability of the heavy-duty design also translates to fewer replacements and reduced maintenance costs over the system's lifecycle.


Frequently Asked Questions


Q1: What are the primary benefits of using the OULU EV510A-0037G/0055P-T4 VFD?

This VFD offers significant energy savings by precisely controlling motor speed, matching output to demand.

It enhances equipment lifespan by providing smooth acceleration/deceleration and reducing mechanical stress.

The unit boasts robust overload capacity, suitable for demanding industrial applications with fluctuating loads.


Q2: Can the OULU EV510A-0037G/0055P-T4 be used with single-phase motors?

No, this model is designed exclusively for three-phase motor applications.

It requires a three-phase input power supply of 380-480V for correct operation.

Using it with single-phase motors or incorrect voltage will result in damage and void the warranty.


Q3: How do I set up basic parameters for motor control on this VFD?

Access the programming menu using the keypad and navigate to motor parameter settings.

Input the motor's rated voltage, current, frequency, and RPM as listed on its nameplate.

Save the parameters and perform a motor auto-tuning sequence for optimal performance.


Q4: What is the typical overload capacity of the OULU EV510A-0037G/0055P-T4?

The VFD can handle 150% of its rated current for up to 60 seconds.

It also supports 120% of its rated current for a continuous duration of 120 seconds.

This heavy-duty capability is crucial for starting high-inertia loads or overcoming momentary peak demands.


Q5: What are the key protection features of this VFD?

It includes over-voltage and under-voltage protection to safeguard against power supply fluctuations.

Over-temperature and short-circuit protection prevent damage to the VFD and connected components.

Overload protection ensures the motor and drive are not subjected to excessive current draw.


Q6: What is the maximum output frequency for the OULU EV510A-0037G/0055P-T4?

The VFD can provide an output frequency range of 0 Hz up to 400 Hz.

This wide frequency range allows for precise speed control across various operational needs.

Higher frequencies enable faster motor speeds, essential for certain high-speed machinery.


Q7: Does this VFD support advanced control methods like vector control?

The EV510A series primarily utilizes V/f control for basic applications.

Some models or optional modules within the OULU EV510A range may offer vector control capabilities.

Check the specific model variant or accompanying documentation for vector control support.


Q8: How is the OULU EV510A-0037G/0055P-T4 installed in an industrial panel?

It is designed for wall-mounting, typically within an electrical control cabinet or enclosure.

Ensure adequate ventilation space around the unit to dissipate heat effectively.

Follow the mounting instructions in the manual for secure and stable installation.


Q9: What common troubleshooting steps should be taken for fault codes?

First, consult the user manual for the specific fault code's meaning and recommended actions.

Commonly, issues relate to power supply instability, incorrect parameter settings, or motor/load problems.

Always disconnect power before performing any inspection or maintenance.


Q10: Can this VFD be integrated into a smart factory or IIoT system?

Integration is possible via optional communication expansion cards supporting various industrial fieldbuses.

This allows for remote monitoring, control, and data acquisition within SCADA or MES systems.

Leveraging these capabilities enhances operational efficiency and enables predictive maintenance.