Siemens 3RT6015-1AB01 Standard Motor Starting Contactor 24VAC 7A 3NO

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3RT6015-1AB01
  • HS: 85364900
Availability:In Stock
$6.91
zhongpingtech

The Siemens 3RT6015-1AB01 is a robust, 3-pole standard motor starting contactor designed for reliable control of industrial electrical loads. Featuring a 24VAC coil voltage and a rated current of 7A, this contactor is engineered for straightforward integration and long-term performance. With three normally open (NO) main contacts, it excels in switching applications where positive contact closure is paramount. Its compact S00 size and screw terminal connections facilitate efficient panel space utilization and secure electrical connections. This Siemens contactor is an ideal choice for motor control circuits, offering dependable operation and compliance with international standards.


Product Specifications


| Feature                  | Specification                                     |

| :----------------------- | :------------------------------------------------ |

| Manufacturer             | Siemens                                           |

| Product Number           | 3RT6015-1AB01                                     |

| Product Class            | SIRIUS                                            |

| Type                     | Standard Motor Starting Contactor                 |

| Number of Main Contacts  | 3 NO (Normally Open)                              |

| Coil Voltage             | 24 VAC (50/60 Hz)                                 |

| Rated Current (AC-3)     | 7 A                                               |

| Rated Operational Power  | 3 kW (at 400V AC-3)                               |

| Size                     | S00                                               |

| Auxiliary Contacts       | 1 NO (Normally Open)                              |

| Terminal Type            | Screw Terminal                                    |

| Max. Insulation Voltage  | 690 V                                             |

| Degree of Pollution      | 3                                                 |

| Shock Resistance (AC)    | 6.7g / 5 ms, 4.2g / 10 ms (rectangular impulse)   |

| Mechanical Service Life  | 30,000,000 operating cycles (contactor typical)   |

| Ambient Operating Temp.  | -25 to +60 °C                                     |

| Installation Altitude    | Max. 2000 m above sea level                       |

| RoHS Compliance          | Yes (since 01.05.2012)                            |

| Net Weight               | 0.220 Kg                                          |

| Packaging Dimensions     | 75.00 x 60.00 x 45.00 mm                          |


Core Features & Market Positioning


The Siemens 3RT6015-1AB01 distinguishes itself within the industrial contactor market through its reliable performance and adherence to global standards, making it a trusted component in motor control systems. As part of the broader SIRIUS product line, it benefits from Siemens' extensive engineering expertise and commitment to quality, ensuring high operational availability and a long mechanical lifespan of up to 30 million cycles. Its compact S00 size is a significant advantage in modern control panels where space is at a premium, allowing for higher density installations. The inclusion of one auxiliary NO contact provides essential signaling capabilities for system monitoring or interlocking, enhancing the overall functionality of the controlled system. Its AC3 rating ensures it is well-suited for direct motor starting applications, offering a balance of performance and cost-effectiveness for many industrial scenarios.


Key Application Scenarios


The Siemens 3RT6015-1AB01 is primarily deployed in applications requiring robust and reliable motor control. Common use cases include starting and stopping three-phase induction motors in manufacturing plants, pumps, fans, compressors, and conveyor systems. Its 24VAC coil voltage makes it compatible with a wide range of control circuits, often found in North American and international automation setups. The contactor's suitability for AC-3 duty cycles signifies its capability to handle the high inrush currents associated with motor starts. Industries benefiting from this component include general manufacturing, material handling, water treatment, and HVAC systems, where dependable switching of motor loads is critical for continuous operation.


Practical System Integration Guidance


Integrating the Siemens 3RT6015-1AB01 into existing or new control systems is straightforward due to its standard S00 size and screw terminal connections. For installation, it can be mounted directly onto a standard 35mm DIN rail or screw-mounted onto a panel. The wiring process involves connecting the control circuit to the 24VAC coil terminals (typically marked A1 and A2) and the power circuit to the main terminals. The three normally open main contacts are wired in series with the motor's power supply to facilitate starting and stopping. The single auxiliary NO contact can be wired into the control logic for feedback or interlock purposes. For comprehensive wiring diagrams and electrical schematics, consulting the official Siemens technical documentation or datasheets is highly recommended.


Operation and Risk Mitigation


Operating the Siemens 3RT6015-1AB01 involves energizing its 24VAC coil to close the main power contacts, thereby connecting the motor to the power supply. De-energizing the coil opens the contacts, stopping the motor. Safe operation necessitates adherence to proper installation procedures and electrical codes. It is crucial to ensure the power source is de-energized before performing any maintenance or wiring. The contactor's maximum insulation voltage is 690V, and it is designed for a pollution degree of 3, indicating its suitability for industrial environments with some dust and moisture. While the 3RT6015-1AB01 is designed for reliability, overload protection should always be implemented alongside the contactor to prevent damage to the motor and the contactor itself in case of an overcurrent situation.


Scalability & Long-Term Value


The Siemens 3RT6015-1AB01, as part of the extensive SIRIUS modular system, offers inherent scalability and long-term value. Additional auxiliary contact blocks (both NO and NC) can be easily added to the front or side of the contactor to expand its control and signaling capabilities, up to four poles. For motor protection, compatible thermal or electronic overload relays can be directly mounted to the contactor, forming a complete motor starter unit. While this specific model doesn't explicitly detail IIoT integration features, Siemens' broader SIRIUS 3RT series and related digital offerings often support connectivity through intelligent motor management devices or gateways, facilitating integration into smart factory environments and IIoT platforms for enhanced diagnostics and predictive maintenance.


Frequently Asked Questions (FAQs)


Q1: What is the primary function of the Siemens 3RT6015-1AB01 contactor?

The Siemens 3RT6015-1AB01 serves as a crucial component for controlling electric motors in industrial settings. It acts as an electrically operated switch, allowing a low-voltage control signal to safely manage high-power circuits for motor operation.


This contactor is designed to switch motor loads, enabling remote start, stop, and jog functions, thereby enhancing operational flexibility and safety in various automated systems. Its robust construction ensures reliable performance across demanding industrial environments.


By controlling the flow of power to a motor, it protects both the motor and the associated electrical infrastructure from damage due to overloads or short circuits when used in conjunction with protective devices.


Q2: Can the Siemens 3RT6015-1AB01 be used for DC motor control?

The Siemens 3RT6015-1AB01 is specifically designed for AC (Alternating Current) applications. Its coil voltage is rated for 24VAC, and its main contacts are rated for AC-3 duty, which is standard for AC motor control.


Using this contactor for DC (Direct Current) applications is generally not recommended and could lead to premature failure or unsafe operating conditions. DC circuits have different arc quenching requirements.


For DC motor control, specific DC contactors or specialized switching devices designed for direct current operation would be necessary to ensure safety and proper functionality.


Q3: What type of overload protection is recommended for the 3RT6015-1AB01?

For comprehensive motor protection, it is highly recommended to pair the Siemens 3RT6015-1AB01 with a compatible overload relay. Siemens offers thermal overload relays (e.g., 3RU1116 series) and electronic overload relays (e.g., 3RB2016 series) that can be directly mounted onto this contactor.


These overload relays are designed to monitor the motor's current draw and trip the control circuit, thereby de-energizing the contactor and stopping the motor if it detects excessive current that could indicate a stall or other fault condition.


Implementing an appropriate overload protection scheme is critical for preventing motor damage, reducing downtime, and ensuring the longevity of both the motor and the contactor.


Q4: How do I wire the Siemens 3RT6015-1AB01?

Wiring involves connecting the control circuit to the 24VAC coil terminals (typically A1 and A2) and the power circuit to the main terminals. The three normally open (NO) main contacts are wired in series with the motor's power supply.


The single auxiliary NO contact can be wired into a control logic circuit for feedback, interlocking, or status indication. Ensure that power is disconnected before making any connections to prevent electrical shock.


Always refer to the official Siemens wiring diagrams or the product datasheet for precise terminal designations and recommended wiring practices specific to your application.


Q5: What does "S00 size" refer to for this contactor?

The "S00 size" designation refers to the physical dimensions and current handling capacity of the Siemens 3RT6015-1AB01 contactor within the SIRIUS product family. It indicates a compact frame size suitable for lower power ratings.


Contactors are categorized into different sizes (e.g., S00, S0, S1, etc.) to help users select the appropriate device based on the required motor horsepower or current rating. The S00 size typically accommodates lower amperage and horsepower applications, like the 7A rating of this particular model.


Choosing the correct size is essential for ensuring reliable operation, preventing nuisance tripping, and optimizing space utilization within electrical control panels.


Q6: Can I add more auxiliary contacts to the 3RT6015-1AB01?

Yes, the Siemens 3RT6015-1AB01 supports the addition of auxiliary contact blocks to expand its functionality. These blocks can typically be mounted to the front or side of the contactor.


Siemens offers various auxiliary contact blocks, including normally open (NO) and normally closed (NC) configurations, allowing for up to four additional contacts to be added. This expansion is useful for more complex control logic and signaling requirements.


Consulting the product's technical documentation will provide specific details on compatible auxiliary contact blocks and the maximum number of contacts that can be fitted to this S00-sized contactor.


Q7: What is the lifespan of the Siemens 3RT6015-1AB01 contactor?

The Siemens 3RT6015-1AB01 is designed for a long operational lifespan. Its mechanical service life is rated at approximately 30 million operating cycles for the contactor itself.


This mechanical lifespan refers to the number of times the contactor can open and close its contacts without mechanical failure, independent of electrical load conditions. Electrical life will be shorter and depends heavily on the switching frequency and load current.


Proper application within its rated parameters, along with appropriate overload protection, will help ensure the contactor achieves its expected service life in industrial applications.


Q8: Is this contactor suitable for hazardous environments?

The Siemens 3RT6015-1AB01 is a standard industrial contactor and is not inherently designed for hazardous or explosive environments (e.g., Class I, Division 1 or Zone 0/1). Such applications require specialized, explosion-proof, or intrinsically safe equipment.


This contactor is rated for a pollution degree of 3, indicating it can handle typical industrial conditions with some dust and moisture, but not extreme or hazardous atmospheres.


For applications in potentially explosive areas, it is imperative to consult with safety experts and select contactors specifically certified for those hazardous location classifications.


Q9: What is the significance of the 24VAC coil voltage?

The 24VAC coil voltage is a common control voltage used in industrial automation. It is considered a relatively safe voltage level, reducing the risk of electrical shock during wiring and maintenance compared to higher voltages.


This voltage rating ensures compatibility with many control power supplies, transformers, and programmable logic controllers (PLCs) commonly found in automated systems, making integration straightforward.


Using a 24VAC coil allows for the operation of the contactor from a low-voltage control circuit, which is typically isolated from the higher power main circuit, enhancing overall system safety and control design flexibility.


Q10: Where can I find the datasheet for the Siemens 3RT6015-1AB01?

Datasheets for the Siemens 3RT6015-1AB01 can typically be found on the official Siemens industry website or through authorized Siemens distributors. Many distributors also provide direct download links for product datasheets.


Searching online using the exact product number "Siemens 3RT6015-1AB01 datasheet" will usually yield several relevant results from official sources and reputable distributors like Electrical.com, Bommro Automation, or MISUMI.


The datasheet provides comprehensive technical specifications, dimensions, application guidelines, and safety information essential for proper selection, installation, and operation of the contactor.

Menu