The DANFOSS FC-301P75KT4E20H2XGCXXXSXXXXAXBXCXXXXDX 75kW VLT AutomationDrive FC-301 stands as a robust, high-performance variable frequency drive engineered for demanding industrial applications. This drive excels in providing precise motor control, significant energy savings, and enhanced operational efficiency across a wide spectrum of industries. Its advanced features and reliability position it as a leading solution for variable speed applications requiring superior performance and longevity. The FC-301 series, specifically the 75kW model, is designed for seamless integration into complex automation systems, offering flexibility and ease of use for system integrators and end-users alike.


Product Specifications


| Parameter            | Value                                      |

| :------------------- | :----------------------------------------- |

| Model Number         | FC-301P75KT4E20H2XGCXXXSXXXXAXBXCXXXXDX     |

| Power Rating         | 75 kW                                      |

| Input Voltage        | 3 Phase, 480V AC                           |

| Output Voltage       | Matches Input Voltage                      |

| Enclosure Type       | IP20 (Standard)                            |

| Control Type         | VLT AutomationDrive FC-301 Series          |

| Ambient Temperature  | -10°C to +50°C (derated above +40°C)       |

| Cooling              | Forced Ventilation                         |

| Overload Capacity    | 150% for 60 seconds, 110% for continuous   |

| Harmonic Distortion  | Integrated harmonic mitigation options     |

| Communication Options| Multiple fieldbus protocols supported      |


Core Features & Market Positioning


The DANFOSS FC-301P75KT4E20H2XGCXXXSXXXXAXBXCXXXXDX 75kW VLT AutomationDrive distinguishes itself through its advanced control algorithms, delivering exceptional motor performance and responsiveness. Its market positioning is defined by its reliability in harsh industrial environments and its energy-saving capabilities, often outperforming competitors in efficiency metrics. The drive's integrated safety functions and robust construction ensure a long service life and reduced maintenance requirements. Furthermore, its modular design facilitates customization and upgrades, providing a future-proof solution for evolving industrial needs. The FC-301 series is recognized for its user-friendly interface and straightforward commissioning process, making it a preferred choice for both new installations and retrofits.


Key Application Scenarios


This 75kW VLT AutomationDrive finds extensive use in applications demanding precise speed and torque control, such as pumps, fans, and conveyors in HVAC, water treatment, and material handling systems. Its ability to handle variable loads efficiently makes it ideal for optimising energy consumption in these sectors. The robust design of the DANFOSS FC-301P75KT4E20H2XGCXXXSXXXXAXBXCXXXXDX is well-suited for process industries like food and beverage, pharmaceuticals, and general manufacturing, where consistent performance and hygiene standards are paramount. Its 480V rating makes it a direct fit for North American and other global installations operating at this voltage level.


Practical System Integration Guidance


Integrating the DANFOSS FC-301P75KT4E20H2XGCXXXSXXXXAXBXCXXXXDX requires careful attention to power supply connections, motor wiring, and control signal routing. Ensure the input power supply is stable and within the specified 480V, 3-phase tolerance. Proper grounding is critical for safety and to prevent electrical noise. Motor connections should be made with shielded cable to minimize electromagnetic interference, especially in environments with other sensitive electronic equipment. For communication, select the appropriate fieldbus module (e.g., Profibus, Modbus TCP/IP) and configure the network settings according to the system's architecture. Initial commissioning involves setting motor parameters, defining speed references, and configuring protective functions. The drive's local control panel and PC-based software tools (like Danfoss's MCT 10) simplify this process, allowing for parameter backup and remote monitoring.


Operation and Risk Mitigation


Operating the DANFOSS FC-301P75KT4E20H2XGCXXXSXXXXAXBXCXXXXDX involves understanding its control modes and safety features. The drive offers various control modes, including V/f control and advanced vector control, allowing optimization for different motor types and load profiles. It is imperative to adhere to the specified operating temperature range of -10°C to +50°C, with derating required above +40°C, to prevent overheating and ensure longevity. Safety functions such as Safe Torque Off (STO) are crucial for preventing unexpected equipment startup, thus mitigating risks during maintenance or emergency stops. Familiarize yourself with common fault codes displayed on the drive's interface; for instance, fault code 05 (Overcurrent) might indicate a motor issue or rapid acceleration, while fault code 11 (Heatsink Temperature) suggests inadequate cooling. Always consult the product manual for detailed troubleshooting steps for specific fault codes.


Scalability & Long-Term Value


The DANFOSS FC-301P75KT4E20H2XGCXXXSXXXXAXBXCXXXXDX 75kW VLT AutomationDrive offers significant long-term value through its inherent scalability and compatibility. Its modular design allows for the addition of various option modules, including communication cards for seamless integration into IIoT platforms and advanced automation systems. This adaptability ensures that the drive can evolve with your plant's automation strategy. For businesses looking to upgrade existing motor control systems, the FC-301 series provides a path to enhanced energy efficiency and improved process control, often leading to substantial operational cost savings over its extended lifespan. Its robust construction and Danfoss's reputation for product reliability contribute to a low total cost of ownership.


FAQs


What is the maximum ambient operating temperature for the DANFOSS FC-301P75KT4E20H2XGCXXXSXXXXAXBXCXXXXDX?

The standard maximum ambient operating temperature for this drive is 50°C. However, derating is necessary when operating above 40°C. This ensures the drive's internal components remain within safe thermal limits.


Exceeding the maximum temperature without derating can lead to premature component failure and reduced drive lifespan. Always monitor drive temperatures in demanding environments.


Consult the technical manual for specific derating curves and guidelines to maintain optimal performance and reliability in high-temperature conditions.


How do I connect a remote potentiometer to the DANFOSS FC-301P75KT4E20H2XGCXXXSXXXXAXBXCXXXXDX?

Connect the potentiometer to the analog input terminals on the drive. Typically, you'll use terminals for 0-10V, 4-20mA, or a voltage supply for the potentiometer.


Configure the drive's parameters to recognize the analog input as the speed reference source. Ensure correct wiring to avoid signal noise or incorrect readings.


Verify the potentiometer's resistance range and output voltage are within the drive's accepted input specifications for accurate speed control.


What are the common causes for a fault code 05 (Overcurrent) on this drive?

An overcurrent fault can stem from a motor that is too large for the drive's rating or a motor with a short circuit. It can also indicate excessive load on the driven equipment.


Rapid acceleration settings can also trigger an overcurrent fault. Adjusting the ramp-up times to be more gradual will often resolve this issue.


Check motor windings for insulation breakdown and ensure the driven machinery is operating within its design limits. Verify that the motor nameplate data matches the drive's configured parameters.

Menu