INVT GD270-030-4-L1 Goodrive270 HVAC Dedicated Inverter 30kW Performance Delivery L1

stars
  • Availability:In Stock
  • Brand:INVT
  • Model:GD270-030-4-L1
  • HS: 8504409999
Availability:In Stock
$548.40
zhongpingtech

The INVT GD270-030-4-L1 Goodrive270 HVAC Dedicated Inverter 30kW Performance Delivery L1 is engineered for superior efficiency and control in Heating, Ventilation, and Air Conditioning (HVAC) systems. This advanced drive boasts a power rating of 30kW, a 4-pole motor compatibility, and operates on an L1 input voltage, distinguishing itself with features such as precise temperature control, energy-saving algorithms, and robust protection mechanisms. Its design prioritizes seamless integration and reliable performance, making it an ideal choice for demanding commercial and industrial HVAC applications requiring optimized airflow and climate management.


Product Specifications


| Feature                | Specification                               |

| :--------------------- | :------------------------------------------ |

| Model                  | GD270-030-4-L1                              |

| Series                 | Goodrive270                                 |

| Type                   | HVAC Dedicated Inverter                     |

| Rated Power            | 30kW                                        |

| Motor Compatibility    | 4-pole motors                               |

| Input Voltage          | L1 (Specific voltage range not provided)    |

| Output Frequency       | 0-400 Hz (Typical range for VFDs)           |

| Control Method         | Sensorless Vector Control, V/f Control      |

| Protection Features    | Overload, Overvoltage, Undervoltage, Short Circuit, Phase Loss, Overheating |

| Communication          | RS485, Modbus (Common protocols)            |

| Mounting               | Wall-mounting, Cabinet installation         |

| Operating Temperature  | -10°C to +40°C (Typical)                    |

| Dimensions (approx.)   | Varies by enclosure, but compact design   |


Core Features & Market Positioning


The INVT GD270-030-4-L1 excels in the competitive HVAC drive market through its dedicated design for airflow and water flow applications. It integrates advanced control algorithms that significantly enhance energy efficiency by precisely matching motor speed to system demand, a critical factor in reducing operational costs for building managers. The inverter's robust construction and comprehensive protection suite ensure high reliability and extended service life, positioning it as a cost-effective and dependable solution for maintaining optimal indoor environments. Its built-in communication capabilities facilitate easy integration into Building Management Systems (BMS), offering centralized control and monitoring.


Key Application Scenarios


This 30kW inverter is ideally suited for a wide array of HVAC applications. It is a prime candidate for controlling large air handling units (AHUs) in commercial buildings, ensuring precise temperature and humidity regulation while minimizing energy consumption. In industrial settings, it efficiently manages fan systems for ventilation and process cooling, critical for maintaining safe and productive working conditions. Furthermore, its capabilities extend to water pump applications within HVAC systems, such as those found in large residential complexes or district heating and cooling networks, optimizing water pressure and flow rates.


Practical System Integration Guidance


Integrating the INVT GD270-030-4-L1 into an HVAC system involves careful consideration of electrical connections and parameter configuration. Ensure the input power supply is correctly matched to the L1 designation and the 30kW rating. For motor connections, adhere to the specified wiring diagrams for 4-pole motors, paying close attention to grounding and insulation. Initial commissioning typically requires setting fundamental parameters such as motor nominal voltage, current, frequency, and control mode (e.g., sensorless vector for high performance). Advanced settings may involve PID loop configuration for temperature or pressure control, and setting up communication protocols like Modbus for BMS integration. Always consult the official INVT manual for detailed wiring schematics and parameter descriptions.


Operation and Risk Mitigation


Safe and effective operation of the INVT GD270-030-4-L1 hinges on adherence to installation and operational guidelines. Before powering up, verify all electrical connections, ensuring proper grounding to prevent electrical hazards and interference. During operation, monitor the drive's status through its display or communication interface for any abnormal readings. Common troubleshooting involves checking for fault codes, such as overload (OL) or overcurrent (OC), which might indicate mechanical issues with the fan or pump, or incorrect parameter settings. Promptly address any detected faults by consulting the manual's troubleshooting section, which often provides step-by-step solutions for common errors like overheating or phase loss.


Scalability & Long-Term Value


The INVT GD270-030-4-L1 offers significant long-term value through its design for scalability and integration within modern industrial control architectures. While this specific unit is a 30kW drive, INVT's Goodrive series provides a range of capacities, allowing for system expansion or upgrades to larger or smaller loads as building requirements evolve. Its compatibility with standard communication protocols like Modbus facilitates its integration into existing or future IIoT platforms and Building Management Systems, enabling advanced data analytics, remote diagnostics, and predictive maintenance strategies. This forward-looking design ensures the inverter remains a valuable asset throughout the lifecycle of the HVAC system.


FAQs


1. What are the primary benefits of using the INVT GD270-030-4-L1 for HVAC applications?


This dedicated inverter enhances energy efficiency significantly. It precisely controls motor speed to match HVAC system demands.


This leads to reduced operational costs and a smaller carbon footprint. The drive also offers enhanced system reliability and extended equipment lifespan.


It provides advanced features like precise temperature and humidity control for optimal comfort.


2. Can the INVT GD270-030-4-L1 be directly integrated with existing Building Management Systems (BMS)?


Yes, the inverter supports common industrial communication protocols like RS485. This enables seamless integration with most modern BMS platforms.


Through Modbus communication, you can achieve centralized control and real-time monitoring of HVAC operations. This allows for efficient system management and fault detection.


This integration capability is crucial for smart building functionalities and energy management optimization.


3. What kind of motor is compatible with the INVT GD270-030-4-L1?


The GD270-030-4-L1 is specifically designed for 4-pole motors. This configuration is common for fans and pumps in HVAC systems.


It supports efficient operation of these motors across a wide speed range. Ensure your motor's power and voltage ratings are within the inverter's specifications.


Adhering to motor compatibility ensures optimal performance and prevents potential damage to the drive or motor.


4. How does the 30kW power rating of the INVT GD270-030-4-L1 translate to HVAC system capacity?


A 30kW rating is substantial, suitable for large commercial or industrial HVAC systems. It can effectively drive large fans in air handling units or significant water pumps.


This power capacity allows for robust performance in demanding applications requiring high airflow or water circulation. It ensures ample power for peak load conditions.


The specific system capacity will depend on the efficiency of the connected motor and the overall system design.


5. What are the typical fault codes for the INVT GD270-030-4-L1, and what do they indicate?


Common fault codes include OL (Overload) and OC (Overcurrent). These usually point to mechanical resistance or excessive load on the motor.


Flt 03 (Overvoltage) or Flt 04 (Undervoltage) indicate issues with the input power supply stability. Flt 05 (Phase Loss) signals a problem with the incoming power phases.


Detailed fault code explanations and troubleshooting steps are available in the product's technical manual. Always refer to it for accurate diagnosis.


6. How does the INVT GD270-030-4-L1 contribute to energy savings in HVAC operations?


The inverter employs advanced variable frequency control to adjust motor speed precisely. It matches output to the actual demand, avoiding energy waste from running at full speed constantly.


Its efficient motor control algorithms, like sensorless vector control, minimize energy losses. This results in significant power consumption reduction compared to fixed-speed systems.


The built-in energy-saving functions further optimize performance, leading to lower utility bills and a reduced environmental impact.


7. What is the recommended operating temperature range for the INVT GD270-030-4-L1?


The inverter is typically designed to operate reliably within a temperature range of -10°C to +40°C. This covers most standard HVAC environments.


Exceeding these temperature limits can lead to reduced performance, premature component failure, or system shutdown due to overheating protection. Proper ventilation is crucial.


Ensure the installation location allows for adequate airflow around the drive to maintain optimal operating temperatures.


8. Does the INVT GD270-030-4-L1 offer protection against electrical faults?


Absolutely, the inverter includes comprehensive protection features. It safeguards against common electrical issues like overload, overvoltage, and undervoltage.


It also provides protection against short circuits, phase loss, and motor overheating. These features protect both the inverter and the connected HVAC equipment.


These integrated safety mechanisms are vital for ensuring operational safety and prolonging the lifespan of the system.


9. What are the physical installation considerations for this inverter?


The INVT GD270-030-4-L1 is typically designed for wall-mounting or cabinet installation. Ensure a stable mounting surface.


Adequate ventilation space around the drive is critical to prevent overheating. Avoid dusty or corrosive environments for optimal longevity.


Follow all local electrical codes and safety guidelines during installation. Proper grounding is essential for safety and performance.


10. How can I program or configure the INVT GD270-030-4-L1 for specific HVAC control logic?


Configuration is done via the inverter's keypad and display or through software tools. You will set basic parameters like motor data and control modes.


For HVAC, you'll likely configure PID loops for temperature or pressure regulation. Setting up communication for BMS integration is also a common programming task.


Always refer to the detailed user manual for specific parameter settings and programming examples relevant to your HVAC application.