SIEMENS VAF41.150-360 Flanged Ball Valve DN150 kvs 360 Two-Way

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:VAF41.150-360
  • HS: 8481804090
Availability:In Stock
$856.24
zhongpingtech

The SIEMENS VAF41.150-360 is a high-performance, flanged two-way ball valve engineered for precise flow control in demanding industrial environments. This DN150 valve boasts a kvs of 360, offering substantial flow capacity and reliability for a wide range of HVAC and industrial process applications. Its robust construction ensures long-term operational integrity, while its advanced design delivers superior shut-off capabilities and minimizes leakage. The VAF41.150-360 is a testament to SIEMENS' commitment to delivering efficient, robust, and technologically advanced flow control solutions for critical systems.


Product Specifications


| Specification       | Value                |

| :------------------ | :------------------- |

| Product Type        | Flanged Ball Valve   |

| Model Number        | VAF41.150-360        |

| Nominal Diameter    | DN150 (6 inches)     |

| Flow Coefficient (kvs) | 360 m³/h             |

| Valve Type          | Two-Way              |

| Connection Type     | Flanged              |

| Actuator Compatibility | Designed for SIEMENS actuators |

| Body Material       | Cast Iron            |

| Seal Material       | EPDM                 |

| Max. Differential Pressure | Varies by actuator, typically 160 kPa for 400 N actuators |

| Temperature Range   | -10…120 °C           |

| Shut-off Leakage    | Class AB to EN 1349  |


Core Features & Market Positioning


The SIEMENS VAF41.150-360 stands out due to its precision engineering and robust construction, positioning it as a superior choice for critical flow regulation tasks. Its high kvs value of 360 for a DN150 size indicates exceptional flow handling capacity, making it ideal for applications where significant water volume needs to be controlled accurately. The valve's two-way configuration simplifies system design for isolation or control functions. SIEMENS' reputation for quality and reliability underpins the market positioning of this valve as a durable, long-term solution for professionals seeking dependable performance in HVAC, district heating, and industrial water systems. The flanged connection ensures secure and leak-free installation in high-pressure or high-vibration environments.


Key Application Scenarios


This SIEMENS VAF41.150-360 flanged ball valve is extensively utilized in building automation and industrial process control. Its DN150 size and kvs of 360 make it particularly suitable for large-scale heating and cooling systems, including district heating networks and large commercial buildings, where precise temperature control of substantial water flow is essential. It is also employed in industrial water management, process cooling circuits, and any application requiring reliable shut-off or proportional control of fluid in a 6-inch pipe system. The valve's suitability for modulating control, when paired with appropriate SIEMENS actuators, allows for energy-efficient management of heating and cooling loads.


Practical System Integration Guidance


Integrating the SIEMENS VAF41.150-360 into existing or new systems is streamlined due to its standardized flanged connection and compatibility with SIEMENS' range of electric actuators. For optimal performance, ensure the valve is installed in a position that allows for easy actuator maintenance. The valve body should be properly supported to prevent undue stress on the flanges. When selecting an actuator, consider the required torque and control signal (e.g., 0-10 V DC, 4-20 mA) for your specific application and desired flow control characteristics. Proper alignment of the valve and mating flange is critical to prevent leaks, and appropriate gasket material, such as EPDM, should be used as specified.


Operation and Risk Mitigation


Safe and efficient operation of the SIEMENS VAF41.150-360 relies on correct installation and actuator pairing. The valve is designed for proportional or two-position control, and its shut-off leakage is classified to EN 1349 standards, ensuring minimal fluid bypass when closed. Potential risks, such as actuator failure or incorrect system pressure, should be mitigated through regular system checks and adherence to the specified operating temperature and pressure limits (e.g., -10 to 120 °C). Ensure actuators are correctly wired and commissioned according to SIEMENS guidelines to prevent unintended valve movements or control issues. Avoid operating the valve outside its specified parameters to maintain its integrity and performance.


Scalability & Long-Term Value


The SIEMENS VAF41.150-360 offers significant long-term value through its robust design and compatibility with SIEMENS' broader automation ecosystem. Its integration with SIEMENS actuators, which often feature advanced diagnostics and communication capabilities, allows for seamless incorporation into digital building management systems (BMS) and Industrial Internet of Things (IIoT) platforms. This enables predictive maintenance, remote monitoring, and data-driven optimization of HVAC and industrial processes. The valve's durable construction, using materials like cast iron and EPDM seals, ensures a long service life, reducing the need for frequent replacements and contributing to lower total cost of ownership.


FAQs


What is the maximum operating pressure for the SIEMENS VAF41.150-360?


The maximum differential pressure is dependent on the selected actuator and specific system conditions. For actuators like the SIEMENS GLB/GLR series with 400 N force, the maximum differential pressure is typically around 160 kPa. Always consult the specific actuator's datasheet for precise pressure ratings and compatibility.


How do I properly install the SIEMENS VAF41.150-360 ball valve?


Ensure the valve is installed in the correct flow direction, typically indicated by an arrow on the valve body. Use appropriate flange gaskets and torque specifications to ensure a leak-free seal between the valve and the piping. Properly support the piping to avoid stressing the valve flanges.


What type of actuator is recommended for the VAF41.150-360?


SIEMENS offers a range of actuators designed for this valve, such as the GLB and GLR series, which provide proportional or two-position control. The selection depends on the required torque, control signal (e.g., 0-10 V DC), and dynamic response needed for your application.


What is the significance of the kvs 360 rating?


The kvs (flow coefficient) of 360 m³/h indicates the volume of water in m³ that will flow through the valve per hour at a pressure drop of 1 bar. A higher kvs means greater flow capacity for a given valve size, making this DN150 valve suitable for high-demand applications.


Can the SIEMENS VAF41.150-360 be used in extreme temperature applications?


The standard operating temperature range for this valve is -10 to 120 °C, with EPDM seals. For applications outside this range, consult SIEMENS for alternative seal materials or specialized versions. Extreme conditions may affect valve performance.


What maintenance is required for the VAF41.150-360?


Regular visual inspection for leaks is recommended. Ensure actuators are functioning correctly and that no debris is obstructing the valve mechanism. Periodic calibration, especially if used for precise control, may be beneficial depending on operational demands.


How does the two-way design of the VAF41.150-360 benefit a system?


A two-way valve is primarily used for flow control or isolation. This design simplifies system configuration compared to a three-way valve, making it ideal for direct on/off control or proportional regulation of flow in a single circuit, such as a heating or cooling loop.


What is the shut-off leakage class of this valve?


The SIEMENS VAF41.150-360 is designed to meet shut-off leakage Class AB according to EN 1349. This signifies a very low level of leakage when the valve is fully closed, crucial for energy efficiency and preventing unwanted fluid circulation.


Is this valve compatible with non-SIEMENS actuators?


While primarily designed for SIEMENS actuators, compatibility with third-party actuators may be possible if they meet the necessary torque, mounting interface (ISO 5211 standard), and control signal requirements. However, using SIEMENS actuators ensures optimal performance and warranty.


Where can I find detailed installation and troubleshooting guides for the VAF41.150-360?


Comprehensive technical documentation, including installation, operation, and troubleshooting guides, is available directly from SIEMENS. These resources provide specific diagrams, wiring examples, and fault code explanations for professional users.

Menu