Delta VFD38AMS43ANSAA MS300 Frequency Converter for Industrial Pumps 38A 18.5kW

stars
  • Availability:In Stock
  • Brand:DELTA
  • Model:VFD38AMS43ANSAA
  • HS: 8504409999
Availability:In Stock
$720.40
zhongpingtech

The Delta VFD38AMS43ANSAA MS300 Frequency Converter is a robust solution engineered for demanding industrial pump applications, offering precise motor control, energy savings, and enhanced operational reliability. This 38A, 18.5kW drive stands out with its advanced features, including a high-performance control core for accurate speed regulation, integrated braking unit for rapid deceleration, and comprehensive protection functions to safeguard equipment. Its compact design facilitates easy installation in tight spaces, while its user-friendly interface simplifies configuration and monitoring. The MS300 series is designed to meet the stringent requirements of various industrial sectors, providing a reliable and efficient means to optimize pump performance and reduce energy consumption.


| Parameter                 | Specification                                  |

| :------------------------ | :--------------------------------------------- |

| Model                     | VFD38AMS43ANSAA                                |

| Series                    | MS300                                          |

| Output Current            | 38A                                            |

| Rated Power               | 18.5kW (25 HP)                                 |

| Input Voltage             | 3-Phase, 380-480V AC                           |

| Output Voltage            | 3-Phase, 380-480V AC                           |

| Frequency Range           | 0 to 600 Hz                                    |

| Control Method            | V/f, Sensorless Vector Control                 |

| Protection Class          | IP20                                           |

| Communication Interface   | Optional Modbus RS-485                         |

| Braking Unit              | Integrated (Standard)                          |

| Operating Temperature     | -20°C to +50°C                                 |

| Dimensions (H x W x D)    | 260 x 147 x 160 mm                             |


Core Features & Market Positioning


The Delta VFD38AMS43ANSAA MS300 positions itself as a leader in variable frequency drive technology for industrial pumps through its exceptional control precision and energy efficiency. Unlike many competitors, the MS300 series incorporates Delta's proprietary control algorithms, delivering superior sensorless vector performance that ensures stable torque and accurate speed across a wide range of load conditions. This translates directly into reduced energy expenditure for pump operations by matching motor speed to system demand, a critical factor in today's cost-conscious industrial environment. Furthermore, its robust design, featuring enhanced thermal management and comprehensive fault diagnostics, minimizes downtime and maintenance costs, making it a highly competitive and reliable choice for continuous industrial processes.


Key Application Scenarios


The Delta VFD38AMS43ANSAA MS300 frequency converter is ideally suited for a multitude of industrial pump applications where precise flow and pressure control are paramount. Common use cases include water supply and distribution systems, wastewater treatment plants, and HVAC circulation pumps, where energy savings can be substantial. Its ability to manage variable loads makes it effective in chemical processing, oil and gas pumping stations, and irrigation systems. The drive's robust construction and advanced protection features also lend themselves to demanding environments found in mining and metal processing industries, ensuring reliable operation of critical pumping machinery.


Practical System Integration Guidance


Integrating the Delta VFD38AMS43ANSAA MS300 into an industrial pump system is straightforward due to its user-friendly design and clear terminal layout. Proper wiring is essential; ensure the input power supply is correctly connected to the L1, L2, and L3 terminals, and the pump motor is connected to T1, T2, and T3. For safety and optimal performance, it is recommended to install an appropriate circuit breaker and external contactor. The integrated braking resistor connection terminals (if applicable and specified for the application) should be wired according to the manual to manage regenerative energy during deceleration. Basic parameter configuration, such as motor data entry, maximum/minimum frequency settings, and acceleration/deceleration times, can be performed via the built-in keypad or through optional communication interfaces.


Operation and Risk Mitigation


Operating the Delta VFD38AMS43ANSAA MS300 frequency converter involves careful attention to setup and monitoring to ensure safety and prevent potential issues. Always adhere to the electrical codes and installation guidelines provided in the product manual, ensuring proper grounding and ventilation to prevent overheating. Familiarize yourself with the common fault codes displayed on the drive's interface; for instance, an "OL" (Overload) fault typically indicates the motor is drawing too much current, which could stem from a mechanical issue with the pump or an undersized drive. An "OC" (Overcurrent) fault suggests a rapid surge in current, often during startup or rapid acceleration. Addressing these faults promptly through troubleshooting steps outlined in the manual, such as checking motor connections, load conditions, and parameter settings, is crucial for mitigating risks and ensuring continuous operation.


Scalability & Long-Term Value


The Delta VFD38AMS43ANSAA MS300 offers significant scalability and long-term value by seamlessly integrating with existing industrial control systems and supporting future advancements. Its optional communication modules, such as Modbus RS-485, allow for easy integration into SCADA systems or programmable logic controller (PLC) networks, enabling centralized monitoring and control of multiple pumping stations. This connectivity facilitates data acquisition for performance analysis and predictive maintenance, aligning with Industry 4.0 initiatives. Furthermore, the drive's robust hardware and Delta's commitment to firmware updates ensure that the unit remains technologically relevant, providing a reliable and cost-effective solution for pump control over its extended operational lifespan.


Frequently Asked Questions (FAQs)


What is the primary function of the Delta VFD38AMS43ANSAA MS300?

This drive precisely controls the speed of industrial pumps. It optimizes energy consumption by matching motor output to demand. It enhances system efficiency and reduces operational costs significantly.


How does this frequency converter save energy in pump applications?

It adjusts motor speed dynamically based on flow or pressure needs. This avoids running pumps at full speed unnecessarily. Reduced speed leads to lower power draw and substantial energy savings.


What are the main technical specifications of the VFD38AMS43ANSAA?

It handles 38A and is rated for 18.5kW (25 HP) motors. It supports 3-phase, 380-480V AC input and output. The frequency range is 0-600 Hz for versatile operation.


Can this Delta drive be used with different types of pumps?

Yes, it is suitable for various industrial pumps. Applications include water, wastewater, HVAC, and chemical processing pumps. Its flexible control modes ensure compatibility.


What communication protocols does the MS300 series support?

The MS300 series primarily supports Modbus RTU. An optional communication board enables RS-485 communication. This allows for remote monitoring and control integration.


How do I install the Delta VFD38AMS43ANSAA safely?

Ensure proper grounding and wiring as per the manual. Install an appropriate circuit breaker for protection. Provide adequate ventilation to prevent overheating and ensure reliable operation.


What does an "OL" fault code signify on this drive?

"OL" indicates an overload condition. The motor is drawing more current than it should. This often points to a mechanical pump issue or excessive load.


How can I troubleshoot an "OC" fault on the VFD38AMS43ANSAA?

"OC" means overcurrent, typically during startup. Check motor connections and parameters. Verify the load is not too heavy for the drive's capacity.


Is the Delta VFD38AMS43ANSAA compatible with existing control systems?

Yes, it offers excellent compatibility. Optional communication cards enable integration with PLCs and SCADA systems. This supports advanced automation and monitoring.


What is the expected lifespan of the Delta MS300 frequency converter?

With proper installation and maintenance, these drives offer a long service life. Robust design and Delta's quality ensure durability in industrial environments. Regular checks optimize longevity.