Delta VFD38AMH43ANSAA MS300 High Performance Frequency Converter 38A 18.5kW

stars
  • Availability:In Stock
  • Brand:DELTA
  • Model:VFD38AMH43ANSAA
  • HS: 8504409999
Availability:In Stock
$793.00
zhongpingtech

The Delta VFD38AMH43ANSAA MS300 High Performance Frequency Converter, a robust 18.5kW, 38A drive, offers advanced motor control solutions for demanding industrial applications. This unit excels with its high performance, precise speed regulation, and comprehensive protection features, making it a reliable choice for various automation tasks. Key technical specifications include an input voltage range of 380-480V AC, an output frequency of up to 600Hz, and integrated braking capabilities. Its advanced control algorithms ensure smooth operation and energy efficiency, positioning it as a superior option in its class for enhancing productivity and reducing operational costs.


Product Specifications


| Feature              | Specification                                 |

| :------------------- | :-------------------------------------------- |

| Model Number         | VFD38AMH43ANSAA                               |

| Series               | MS300                                         |

| Power Rating         | 18.5 kW                                       |

| Output Current       | 38 A                                          |

| Input Voltage        | 380-480V AC                                   |

| Output Frequency     | 0.00 to 600.00 Hz                             |

| Control Method       | V/f Control, Vector Control                   |

| Protection Class     | IP20                                          |

| Braking Unit         | Integrated (Optional external resistor)       |

| Communication        | RS-485 (Modbus)                               |

| Operating Temperature| -20°C to +50°C                                |


Core Features & Market Positioning


The Delta MS300 series, including the VFD38AMH43ANSAA, distinguishes itself through its adoption of Delta's proprietary high-speed control technology, enabling precise speed and torque regulation even under fluctuating loads. This advanced control differentiates it from many competitors offering basic V/f control, providing superior dynamic response. The integrated braking unit enhances safety and control during deceleration, a critical feature not always standard in comparable drives. Its compact design and robust build quality, coupled with an IP20 rating, facilitate installation in various industrial environments, solidifying its position as a high-performance, reliable, and versatile frequency converter for modern automation needs.


Key Application Scenarios


This Delta VFD38AMH43ANSAA frequency converter is ideally suited for applications demanding precise motor control and high torque, such as in conveyor systems, pumps, fans, and machine tools. Its ability to handle variable loads efficiently makes it a prime candidate for HVAC systems seeking energy savings and precise climate control. The drive's robust performance is also beneficial in plastic machinery, textile production, and packaging equipment where consistent speed and torque are paramount for product quality and throughput. Users often seek these drives for retrofitting older machinery to improve efficiency and control.


Practical System Integration Guidance


Integrating the VFD38AMH43ANSAA involves careful consideration of wiring and parameter setup. Ensure the input power supply conforms to the 380-480V AC range and is adequately protected with appropriate circuit breakers or fuses. Motor wiring should follow standard three-phase connections to the drive's output terminals (T1, T2, T3). For optimal performance, particularly in applications requiring precise torque control, utilizing the vector control mode is recommended, which may necessitate motor data autotuning during commissioning. The integrated RS-485 port supports Modbus communication, allowing for seamless integration into SCADA or PLC-based control systems for remote monitoring and control.


Operation and Risk Mitigation


Safe operation of the Delta VFD38AMH43ANSAA requires adherence to electrical safety standards and the drive's manual. Always ensure power is disconnected before performing any wiring or maintenance. Proper grounding of the drive and motor is essential to prevent electrical hazards and ensure reliable operation. Common fault codes, such as overload (F01) or external fault (F14), indicate specific issues that require diagnosis according to the drive's troubleshooting guide. Understanding and addressing these codes promptly helps mitigate potential equipment damage and operational downtime.


Scalability & Long-Term Value


The MS300 series offers inherent scalability through its Modbus communication capabilities, allowing for integration into larger industrial automation networks and IIoT platforms. This connectivity enables centralized control, data logging, and predictive maintenance strategies, enhancing the long-term value of the investment. Compatibility with a wide range of Delta's automation products, including PLCs and HMIs, further simplifies system expansion and upgrades. The drive's robust design and energy-saving features contribute to reduced operational expenses, ensuring a favorable return on investment over its lifecycle.


FAQs


What are the primary benefits of using the Delta VFD38AMH43ANSAA?

This drive provides high-performance motor control with precise speed and torque regulation. It offers enhanced energy efficiency through advanced control algorithms. The integrated protection features safeguard both the drive and the connected motor.


The VFD38AMH43ANSAA excels in dynamic response, crucial for variable load applications. Its robust design ensures reliability in harsh industrial environments. The drive facilitates smoother acceleration and deceleration for machinery.


Users benefit from reduced operational costs due to optimized energy consumption. Improved process control leads to higher product quality and consistency. The drive's advanced features simplify automation integration.


How do I properly wire the Delta VFD38AMH43ANSAA for a three-phase motor?

Connect the incoming three-phase power supply (L1, L2, L3) to the drive's power input terminals. Ensure proper grounding of the drive's chassis and the motor frame. Connect the motor's three output leads (T1, T2, T3) to the corresponding output terminals on the drive.


Refer to the VFD38AMH43ANSAA installation manual for specific terminal designations and torque requirements. Always verify wiring before applying power to prevent damage. Use appropriately sized conductors for both power input and motor output connections.


For braking applications, connect an external braking resistor to the designated terminals (if applicable and required for the load profile). Ensure the braking resistor's wattage and resistance match the drive's specifications.


What is the typical input voltage range for the Delta MS300 series, specifically the VFD38AMH43ANSAA?

The VFD38AMH43ANSAA operates within a standard industrial input voltage range of 380 to 480 Volts AC. This range is common in many international industrial power grids. Always verify your local power supply specifications to ensure compatibility.


It is crucial to confirm that the available power supply matches the drive's rated input voltage. Using an incorrect voltage can lead to malfunction or permanent damage to the frequency converter. Check the nameplate on the drive for precise voltage ratings.


This drive is designed for three-phase power input within the specified voltage parameters. Ensure your power source is stable and meets the requirements for reliable operation of the 18.5kW motor it controls.


Can the Delta VFD38AMH43ANSAA be used for pump and fan applications?

Yes, the VFD38AMH43ANSAA is highly suitable for pump and fan applications due to its variable speed control capabilities. It allows for precise flow and pressure regulation, optimizing system performance. This leads to significant energy savings compared to fixed-speed operation.


The drive's ability to adjust motor speed based on demand minimizes energy waste in HVAC systems and water management. It also reduces mechanical stress on pumps and fans, extending equipment lifespan. The drive can be programmed for specific application profiles.


For these applications, consider utilizing the drive's built-in PID controller for automatic regulation. This eliminates the need for external controllers, simplifying system design. Ensure proper motor tuning for efficient operation.


What communication protocols does the VFD38AMH43ANSAA support for system integration?

The VFD38AMH43ANSAA primarily supports the Modbus RTU protocol via its RS-485 serial communication interface. This allows for seamless integration with Programmable Logic Controllers (PLCs), Human-Machine Interfaces (HMIs), and SCADA systems. This enables remote monitoring, parameter setting, and control.


Modbus RTU is a widely adopted industrial communication standard, ensuring broad compatibility with various automation devices. It allows for efficient data exchange regarding speed, status, fault codes, and operational parameters. Configure the communication parameters carefully for successful network integration.


This protocol facilitates centralized management of multiple drives within a factory automation network. It is essential for implementing advanced control strategies and data acquisition for process optimization and diagnostics. Ensure correct wiring of the RS-485 bus.


How does the Delta VFD38AMH43ANSAA handle motor overload conditions?

The VFD38AMH43ANSAA incorporates advanced electronic overload protection mechanisms to safeguard the motor. It monitors motor current and torque in real-time, triggering an alarm or shutdown if preset limits are exceeded. This prevents motor winding damage.


If an overload condition is detected, the drive will typically display an overload fault code (e.g., F01) and cease motor operation. The protection settings, including overload trip levels and time delays, can be adjusted via the drive's parameter menu to match specific motor and application requirements.


After an overload fault, it is crucial to investigate the cause before resetting the drive. This may involve checking for mechanical issues, incorrect motor sizing, or excessive load demands. Resetting without addressing the root cause can lead to repeated faults.


What is the power rating and output current of the VFD38AMH43ANSAA?

The Delta VFD38AMH43ANSAA is rated for a substantial 18.5 kilowatts (kW) of motor power. This makes it suitable for driving larger industrial motors and heavier loads. It provides ample power for demanding applications.


Complementing its power rating, this frequency converter delivers a maximum output current of 38 Amperes (A). This current capacity ensures it can adequately supply the necessary power to the motor under full load conditions. It aligns with the 18.5kW power output.


The combination of 18.5kW power and 38A current output positions this drive for robust industrial use. It is designed to handle continuous operation with motors requiring significant torque and power. Always ensure your motor's nameplate current rating is within this limit.


What is the significance of the IP20 protection class for this drive?

An IP20 rating signifies that the VFD38AMH43ANSAA offers protection against solid objects greater than 12.5 mm in diameter. It also provides no protection against water ingress, meaning it should be installed in a clean, dry environment. Avoid exposing it to dust or moisture.


This classification indicates that the drive is designed for installation within an enclosure, control panel, or electrical cabinet. This protects the internal components from accidental contact by personnel and prevents the entry of larger foreign objects. It is not suitable for direct outdoor or wet environments.


The IP20 rating implies the need for careful consideration of the installation location to ensure its longevity and operational safety. It mandates mounting within a suitable housing that provides additional environmental protection as required by the specific industrial setting.


Does the VFD38AMH43ANSAA have built-in braking capabilities?

Yes, the VFD38AMH43ANSAA features an integrated braking unit, allowing for dynamic braking to decelerate the motor quickly. This enhances stopping accuracy and safety for the connected machinery. It can effectively dissipate braking energy.


For applications requiring more intensive or frequent braking, an external braking resistor can be connected to the drive. This resistor absorbs the regenerative energy produced during deceleration, preventing over-voltage faults and ensuring controlled stopping. Consult the manual for resistor selection.


The presence of a braking capability is particularly valuable in applications where loads need to be stopped rapidly, such as hoists, elevators, or material handling equipment. It contributes to improved process control and operational safety.


What are the typical fault codes encountered with the Delta MS300 series and how can they be resolved?

Common fault codes include F01 (Overload), F02 (Overvoltage), F03 (Undervoltage), and F04 (Inverter Over-temperature). F01 typically indicates the motor is drawing too much current due to excessive load or improper tuning. Overvoltage and undervoltage (F02/F03) usually point to power supply issues or regenerative braking problems.


Resolving F01 involves checking for mechanical binding, ensuring the motor's nameplate data is correctly entered, and verifying that the load does not exceed the drive's capacity. For F02/F03, inspect the input power quality, check the braking resistor (if used) for proper function, and ensure the drive is adequately ventilated.


Other frequent codes like F14 (External Fault) signal an input from a connected safety device. Always refer to the VFD38AMH43ANSAA operation manual for a complete list of fault codes and their specific troubleshooting procedures. Proper diagnosis is key to quick resolution.

Menu