The SIMPHOENIX DL100-2S0007, a 0.75kW AC Variable Frequency Drive (VFD), stands out in the industrial automation landscape for its robust performance and versatile application capabilities. Engineered for precision motor control, this drive offers significant advantages including energy efficiency, enhanced process control, and extended equipment lifespan. Its core features, such as advanced vector control algorithms and comprehensive protection functions, position it as a reliable solution for demanding industrial environments. Key technical parameters include a rated power of 0.75kW, input voltage compatibility, and a configurable output frequency range, making it a potent tool for optimizing machinery performance across various sectors.
Product Specifications
| Parameter | Specification |
| :----------------- | :---------------------------- |
| Model Number | SIMPHOENIX DL100-2S0007 |
| Rated Power | 0.75 kW (1 HP) |
| Input Voltage | 1-Phase 200-240V AC, 50/60Hz |
| Output Voltage | 3-Phase 0-240V AC |
| Output Frequency | 0-600 Hz |
| Overload Capacity | 150% for 60s |
| Control Method | V/f Control, Vector Control |
| Protection Features| Over-voltage, Under-voltage, Overcurrent, Overload, Overheating, Short circuit, etc. |
| Mounting Type | Wall/DIN rail mountable |
| Communication | RS485 (optional) |
Core Features & Market Positioning
The SIMPHOENIX DL100-2S0007 distinguishes itself through its sophisticated control technologies, particularly its advanced vector control capabilities, which enable superior torque precision and dynamic response even at low speeds. This level of performance is critical for applications requiring tight process control, such as in packaging machinery, textile manufacturing, and food processing. Its robust overload capacity of 150% for 60 seconds ensures reliable operation during transient load demands, a common challenge in many industrial settings. Furthermore, the drive's comprehensive suite of protection features, including over-voltage, under-voltage, overcurrent, and overheating protection, significantly enhances operational safety and minimizes downtime by preventing equipment damage. These attributes collectively position the DL100-2S0007 as a high-value, dependable solution that offers a competitive edge in terms of performance, reliability, and operational longevity compared to standard V/f-only drives.
Key Application Scenarios
This 0.75kW VFD is exceptionally well-suited for a wide array of industrial applications where precise speed and torque control are paramount. In the food and beverage industry, it excels in conveyor systems, mixers, and packaging lines, ensuring consistent product quality and efficient throughput. The textile industry benefits from its accurate speed regulation for spinning, weaving, and dyeing machinery, leading to improved fabric quality and reduced waste. For water treatment facilities, the DL100-2S0007 is ideal for pump and fan control, enabling significant energy savings through optimized flow rates and pressure management. Its ability to precisely control motor speed also makes it a valuable component in material handling systems, such as automated guided vehicles (AGVs) and conveyor belts, enhancing operational efficiency and safety.
Practical System Integration Guidance
Integrating the SIMPHOENIX DL100-2S0007 into existing industrial systems is streamlined due to its user-friendly design and flexible configuration options. For power connections, ensure the single-phase input supply conforms to the drive's specified voltage range (200-240V AC, 50/60Hz) and is properly fused or protected by a circuit breaker. Connect the motor to the drive's output terminals (U, V, W), adhering to the motor's nameplate specifications for current and voltage. Grounding is crucial; connect the drive's ground terminal to a reliable earth ground. Commissioning typically involves setting basic motor parameters, such as rated voltage, current, and frequency, through the drive's keypad or via optional communication interfaces like RS485. For advanced applications, configuring the control mode (V/f or vector control) and adjusting acceleration/deceleration ramps will optimize performance for specific loads.
Operation and Risk Mitigation
Safe and efficient operation of the SIMPHOENIX DL100-2S0007 VFD is achieved through adherence to operating procedures and understanding its protective functions. Before powering on, verify all wiring connections and ensure the motor is properly connected and insulated. Always operate the drive within its specified environmental conditions, avoiding extreme temperatures, humidity, or dust. Key risk mitigation strategies include regularly inspecting power cables for damage, ensuring adequate ventilation around the drive to prevent overheating, and establishing a lockout/tagout procedure for maintenance activities. In the event of a fault, consult the drive's manual to identify the specific error code displayed. Common fault codes, such as E01 (Over-voltage), E02 (Under-voltage), or E03 (Overcurrent), indicate specific issues that require investigation and corrective action, ranging from adjusting control parameters to addressing external system problems like mechanical binding.
Scalability & Long-Term Value
The SIMPHOENIX DL100-2S0007 provides excellent long-term value and scalability for evolving industrial needs. Its compatibility with a broad range of standard three-phase induction motors ensures seamless integration into existing machinery and allows for easy motor upgrades if required. The optional RS485 communication interface enables integration into Supervisory Control and Data Acquisition (SCADA) systems and Programmable Logic Controllers (PLCs), paving the way for advanced process monitoring, diagnostics, and remote control. This connectivity is fundamental for implementing Industry 4.0 initiatives, allowing for data collection for predictive maintenance and operational optimization. As production demands increase or processes become more sophisticated, multiple DL100-2S0007 drives can be networked, offering a scalable solution that grows with the business without necessitating a complete system overhaul.
Frequently Asked Questions
What is the primary function of the SIMPHOENIX DL100-2S0007?
It precisely controls motor speed and torque. It enables energy savings by adjusting power to load needs. This VFD protects motors from electrical faults.
How do I connect a motor to the SIMPHOENIX DL100-2S0007?
Connect motor leads to terminals U, V, and W. Ensure correct phase and voltage matching. Always verify wiring before powering up.
What are the benefits of using this VFD in pump applications?
It allows for variable speed control of pumps. This optimizes water flow and pressure management. Energy consumption is significantly reduced by matching speed to demand.
Can the SIMPHOENIX DL100-2S0007 be used with single-phase motors?
No, this drive is designed for three-phase motors. It converts single-phase input to three-phase output. Always use a three-phase motor with this drive.
What is the meaning of overload capacity in the specifications?
It indicates the drive's ability to handle temporary excess current. The DL100-2S0007 can manage 150% of its rated current for 60 seconds. This ensures smooth operation under peak loads.
How do I troubleshoot common fault codes on this drive?
Consult the product manual for code definitions. Common faults include overcurrent and over-voltage. Verify motor load and power supply stability.
Is RS485 communication standard on this model?
No, RS485 communication is typically an optional feature. It allows for integration with control systems. Check your specific model's configuration.
What is the typical lifespan of a SIMPHOENIX VFD?
Lifespan depends on usage and environment. Proper installation and maintenance are key. Expect many years of reliable service with good care.
How does vector control differ from V/f control on this drive?
Vector control offers superior torque accuracy and response. V/f control is simpler and suitable for basic speed regulation. Vector control is better for dynamic loads.
Where can I find the user manual for the DL100-2S0007?
The manual is usually available on the SIMPHOENIX website. It can also be provided by your distributor. It contains detailed setup and troubleshooting.