YASKAWA CH70B4003ABBA CH700 Advanced Control VFD 3.4A 0.75kW

stars
  • Availability:In Stock
  • Brand:YASKAWA
  • Model:CH70B4003ABBA
  • HS: 8504409999
Availability:In Stock
$374.00
zhongpingtech

The YASKAWA CH70B4003ABBA CH700 Advanced Control VFD is a powerful and versatile variable frequency drive designed for precise motor control in demanding industrial applications. With a 3.4A current rating and a 0.75kW (1HP) power capacity, this unit delivers exceptional performance and efficiency. Its advanced control capabilities ensure smooth acceleration, deceleration, and speed regulation, leading to optimized process throughput and reduced energy consumption. The CH700 series is engineered for reliability and ease of integration, making it a preferred choice for system integrators and end-users seeking robust and intelligent motor drive solutions.


Product Specifications


| Feature              | Specification                |

| :------------------- | :--------------------------- |

| Model Number         | CH70B4003ABBA                |

| Series               | CH700                        |

| Rated Current        | 3.4 A                        |

| Rated Power          | 0.75 kW (1 HP)               |

| Input Voltage        | 3-Phase, 200-240V AC         |

| Output Frequency     | 0-400 Hz                     |

| Control Method       | V/f, Vector Control          |

| Protection Features  | Overcurrent, Overvoltage, Undervoltage, Overtemperature, etc. |

| Communication        | Built-in RS-485 (Modbus RTU) |

| Ambient Temperature  | -10°C to +50°C               |


Core Features & Market Positioning


The YASKAWA CH70B4003ABBA stands out in the competitive VFD market due to its advanced control algorithms, particularly its robust vector control capabilities, which provide superior torque performance and precise speed regulation even under fluctuating loads. This differentiation is crucial for applications requiring high dynamic response and stability, positioning the CH700 series as a premium solution for critical industrial processes. The drive's inherent reliability, a hallmark of Yaskawa products, further enhances its market appeal, minimizing downtime and associated operational costs for businesses. Its integrated communication features, such as the built-in RS-485 port supporting Modbus RTU, facilitate seamless integration into existing SCADA and PLC systems, offering a competitive edge in terms of network connectivity and data exchange.


Key Application Scenarios


This VFD finds extensive application across various industrial sectors where precise motor control is paramount. It is highly effective in powering fans and pumps in HVAC systems and water treatment plants, where variable speed operation leads to significant energy savings and operational efficiency. The CH700 series is also a strong candidate for conveyor systems in manufacturing and material handling, ensuring smooth product flow and accurate positioning. Its robust design and advanced control make it suitable for machine tools, textile machinery, and other processing equipment requiring consistent torque and speed performance under dynamic conditions.


Practical System Integration Guidance


Integrating the YASKAWA CH70B4003ABBA into an existing system is streamlined through its user-friendly interface and comprehensive documentation. Ensure proper electrical isolation and grounding practices are followed during installation to prevent damage and ensure safety. For programming, the drive supports parameter adjustments via the built-in keypad or through PC-based software like Yaskawa's DriveWizard. Key parameters to configure include motor data (rated voltage, current, frequency, poles), acceleration/deceleration times, and desired control mode (V/f or vector). Establishing communication via the RS-485 port involves configuring the Modbus address and baud rate on both the VFD and the master control device, enabling real-time monitoring and control.


Operation and Risk Mitigation


Safe and efficient operation of the YASKAWA CH70B4003ABBA VFD hinges on adherence to the manufacturer's guidelines and understanding its operational parameters. Proper ventilation is critical to prevent overheating; ensure sufficient clearance around the drive as specified in the installation manual. Familiarize yourself with common fault codes displayed on the drive's interface to quickly diagnose and resolve issues. For instance, an "OC" (Overcurrent) fault often indicates an excessive load or rapid acceleration setting, while an "OV" (Overvoltage) fault might suggest issues with the power supply or regenerative braking. Always disconnect power before performing any maintenance or wiring changes to mitigate electrical hazards.


Scalability & Long-Term Value


The YASKAWA CH700 series, including the CH70B4003ABBA, is designed with scalability and long-term value in mind. Its compatibility with Yaskawa's broader automation ecosystem allows for seamless integration with other Yaskawa products like PLCs and servo drives, enabling sophisticated machine automation solutions. The drive's modular design and support for various communication protocols facilitate future upgrades and integration into emerging Industrial IoT (IIoT) platforms, allowing for enhanced data analytics and predictive maintenance capabilities. This forward-looking approach ensures that investments in the CH700 series remain relevant and valuable as industrial automation technologies evolve.


Frequently Asked Questions


How do I perform a motor auto-tuning on the YASKAWA CH70B4003ABBA?

Motor auto-tuning calibrates the VFD to the specific motor's characteristics. Access the parameter group for auto-tuning (typically P1-XX) via the drive's keypad. Ensure the motor is connected and powered, then initiate the tuning process.


The drive will then perform a series of tests to determine motor parameters like resistance, inductance, and inertia. This ensures optimal performance and precise speed/torque control, especially crucial for vector control modes.


After successful tuning, save the parameters and restart the VFD. Refer to the CH700 manual for specific parameter numbers and detailed instructions pertinent to your application.


What are the main advantages of using the CH700 series over other VFDs?

The CH700 series offers superior control performance with advanced vector control capabilities for precise speed and torque management. Its robust construction ensures high reliability in demanding industrial environments, minimizing downtime.


It features flexible programming options and supports multiple communication protocols, facilitating easy integration into various automation systems. This makes it adaptable to diverse application needs and future system expansions.


Additionally, Yaskawa's strong reputation for quality and support provides users with confidence in the longevity and performance of the CH70B4003ABBA, offering excellent long-term value.


Can the YASKAWA CH70B4003ABBA be used with a single-phase input power supply?

No, the YASKAWA CH70B4003ABBA is designed exclusively for three-phase input power supply, typically ranging from 200-240V AC. Using it with a single-phase supply will result in damage to the drive and will not function correctly.


It is essential to verify your facility's power supply configuration before installation. Connecting a three-phase VFD to a single-phase source is a common mistake that can lead to immediate equipment failure and safety hazards.


Always consult the product specifications and local electrical codes to ensure correct power supply compatibility. For single-phase applications, Yaskawa offers specific VFD models designed for such requirements.


What is the maximum operating temperature for the CH70B4003ABBA VFD?

The YASKAWA CH70B4003ABBA VFD has a maximum operating ambient temperature rating of +50°C (122°F). Operating the drive within this limit is crucial for maintaining its performance and ensuring its longevity.


Exceeding this temperature can lead to derating or premature failure of internal components due to excessive heat. Proper ventilation and ensuring adequate airflow around the drive are critical to dissipate heat effectively.


If the ambient temperature in the installation location consistently approaches or exceeds this limit, consider using external cooling solutions or derating the VFD's output capacity to operate within safe thermal parameters.


How do I set up Modbus communication on the CH70B4003ABBA?

To set up Modbus communication, you must configure specific communication parameters within the VFD. This typically includes setting the device address (Slave ID), baud rate, data bits, parity, and stop bits to match the master controller.


You will find these parameters within the drive's communication parameter group (often starting with 'H' or 'C' in the parameter list). Ensure consistency between the VFD's settings and those of your PLC or SCADA system for successful communication.


Once configured, you can exchange data such as speed commands, status monitoring, and fault information. Refer to the CH700 series programming manual for the exact parameter numbers and detailed configuration steps.


What are common causes for an "OC" (Overcurrent) fault on this drive?

An "OC" fault on the YASKAWA CH70B4003ABBA VFD typically indicates that the motor current has exceeded the drive's programmed limit. Common causes include sudden acceleration demands, mechanical overload on the motor shaft, or short circuits.


Rapid changes in load or attempts to accelerate the motor too quickly can also trigger this fault. Inspect the driven machinery for any binding or increased friction. Ensure that the acceleration time parameters are set appropriately for the application.


Verify that the motor is correctly sized for the load and that the VFD's current limit parameter is set correctly. Loose wiring or motor phase issues can also manifest as overcurrent conditions.


What is the power rating of the YASKAWA CH70B4003ABBA?

The YASKAWA CH70B4003ABBA VFD has a rated power output of 0.75 kW, which is equivalent to approximately 1 horsepower (HP). This specification indicates the maximum continuous motor power the drive can safely supply.


This power rating makes it suitable for a wide range of industrial applications involving motors within this power range. Always ensure the motor's nameplate power rating does not exceed the VFD's capacity to prevent damage.


While it can handle 1 HP motors, it's also versatile enough for slightly smaller motors if the application requires precise control and advanced features offered by the CH700 series.


Does this VFD support regenerative braking?

The YASKAWA CH700 series, including the CH70B4003ABBA, does not inherently include a built-in regenerative braking resistor. However, it is designed to support external regenerative braking components if the application requires rapid deceleration or frequent stopping where energy recovery is beneficial.


If your application involves loads with high inertia or requires quick stops, you might need to add an external braking resistor or a regenerative braking unit to dissipate the energy generated during deceleration. Without this, the drive may fault due to overvoltage.


Consult the CH700 series manual for details on configuring the drive to work with external braking resistors and for information on selecting the appropriate braking unit for your specific load requirements.


What is the input voltage range for the CH70B4003ABBA?

The YASKAWA CH70B4003ABBA VFD is designed to operate with a three-phase AC input voltage in the range of 200 to 240 Volts. It is crucial to supply the correct voltage to ensure proper operation and prevent damage to the drive.


Supplying a voltage outside this specified range can lead to malfunction or permanent damage to the VFD. Always verify the available power supply voltage at the installation site before connecting the drive.


This input voltage range is standard for many industrial power systems, making the CH70B4003ABBA compatible with a wide array of equipment found in manufacturing facilities and other industrial settings.


How can I reset the drive to factory default settings on the CH70B4003ABBA?

To reset the YASKAWA CH70B4003ABBA VFD to its factory default settings, you need to access the parameter list and locate the parameter responsible for reset functions. Typically, this involves setting a specific parameter to a designated value to initiate the reset.


You will need to navigate through the drive's menu using the keypad. Parameter Group 'b' (or similar) often contains reset functions, such as 'b1-01' for parameter initialization. Setting this parameter to '1' or a specific code usually triggers the reset.


After performing the reset, it is essential to re-enter critical motor data and application-specific parameters, as all custom settings will be erased. Always refer to the official CH700 series manual for the precise parameter number and procedure for your VFD model.

Menu