DANFOSS FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX 37kW 73A VLT HVAC Drive 3AC 480V IP55

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$3853.80
zhongpingtech

The Danfoss VLT HVAC Drive FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX is a high-performance variable speed drive engineered for demanding HVAC applications, offering precise control, significant energy savings, and robust reliability. This 37kW, 73A unit operates on a 3-phase 480V supply and boasts an IP55 enclosure for superior protection against dust and water ingress, making it ideal for challenging environmental conditions. Its advanced features and compact design simplify integration, while its intelligent motor control algorithms ensure optimal performance and extended equipment lifespan.


| Parameter             | Value                                    |

| :-------------------- | :--------------------------------------- |

| Model Number          | FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX  |

| Power Rating          | 37 kW                                    |

| Rated Current         | 73 A                                     |

| Input Voltage         | 3 Phase, 480V AC                         |

| Enclosure Rating      | IP55                                     |

| Series                | VLT HVAC Drive FC-101                    |


Core Features & Market Positioning


The Danfoss FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX stands out in the HVAC drive market due to its specialized design for building automation systems. It incorporates advanced algorithms for precise control of fans, pumps, and chillers, leading to substantial energy efficiency improvements – often exceeding 50% compared to traditional fixed-speed systems. The drive's intelligent thermal management and built-in harmonic mitigation capabilities reduce stress on connected equipment and minimize electrical disturbances, enhancing overall system reliability and reducing maintenance costs. Its positioning as a premium, yet cost-effective, solution for modern HVAC infrastructure is reinforced by its integration-ready features and comprehensive communication options.


Key Application Scenarios


This VLT HVAC Drive is exceptionally well-suited for a wide array of commercial and industrial HVAC applications. It excels in controlling variable air volume (VAV) systems, circulating pumps, cooling towers, and chillers, where precise flow and pressure regulation are paramount. Its IP55 rating ensures reliable operation in environments such as mechanical rooms, rooftops, or areas prone to dust and moisture, common in hospitals, data centers, and large commercial buildings. The drive's ability to adapt to changing building loads efficiently translates into significant operational cost savings and enhanced occupant comfort.


Practical System Integration Guidance


Integrating the Danfoss FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX is streamlined through its user-friendly interface and comprehensive connectivity options. Wiring should adhere to local electrical codes, with proper grounding and conductor sizing being critical. The drive supports various fieldbus protocols, allowing seamless integration into Building Management Systems (BMS) for centralized monitoring and control. Commissioning typically involves parameterization of motor data, application-specific settings for fan or pump control, and establishing communication links. For instance, setting the maximum frequency and ramp times allows for smooth acceleration and deceleration, protecting mechanical components.


Operation and Risk Mitigation


Safe and efficient operation of the Danfoss FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX hinges on adhering to operational guidelines and understanding potential fault conditions. Always ensure the drive is properly grounded and that power connections are secure before energization. Regular visual inspections for dust accumulation or damage to the enclosure are recommended. Common troubleshooting often involves checking for overcurrent, overvoltage, or undervoltage faults, which can usually be resolved by verifying motor parameters, supply voltage stability, and ensuring the load is within the drive's capabilities. Understanding specific error codes, detailed in the drive's manual, is crucial for rapid diagnosis and resolution.


Scalability & Long-Term Value


The Danfoss FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX offers excellent scalability and long-term value for evolving HVAC infrastructures. Its modular design and compatibility with Danfoss's broader VLT® drive family facilitate system expansion and upgrades. The drive's advanced communication protocols enable integration with Industrial Internet of Things (IIoT) platforms, allowing for predictive maintenance, remote diagnostics, and data analytics, further optimizing operational efficiency and asset management. This forward-looking design ensures that the drive remains a relevant and valuable component of smart building technology for years to come.


Frequently Asked Questions


What are the primary benefits of using the Danfoss FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX?

This drive offers significant energy savings by precisely matching motor speed to system demand. It enhances system reliability with advanced motor protection features and reduces wear on connected equipment.

The robust IP55 enclosure ensures durability in challenging industrial and commercial HVAC environments. Its intelligent control algorithms optimize performance and reduce operational costs.


How do I connect the Danfoss FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX to a BMS?

Connect the drive to your Building Management System using its supported fieldbus communication options. Ensure the correct communication module is installed and configured.

Refer to the drive's manual for specific wiring diagrams and parameter settings for your chosen protocol (e.g., BACnet, Modbus). Establish network connectivity and test data exchange.


What are common troubleshooting steps for the FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX?

First, check for active alarm codes displayed on the drive's interface. Verify motor nameplate data and ensure it matches drive parameters.

Inspect power supply voltage and ensure it is within the drive's operating range. Check for any overload conditions or mechanical obstructions in the driven equipment.

Confirm all wiring connections are secure and correctly made, especially grounding. Consult the drive's troubleshooting guide for specific error code resolutions.


Can the Danfoss FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX control multiple motors?

Typically, a single drive is designed to control one motor directly for optimal performance and protection. Using a drive for multiple motors can lead to uneven load distribution and control issues.

If multiple motors are required, consider using separate drives for each, or consult with Danfoss for specialized multi-motor control solutions if available for this series.

Overloading the drive by connecting more motors than its rating can handle will result in faults and potential damage.


What is the importance of the IP55 rating for this VLT HVAC Drive?

The IP55 rating signifies protection against dust ingress and water projected from any direction. This makes the drive suitable for installation in less controlled environments.

It ensures the drive can withstand typical conditions found in mechanical rooms or outdoor enclosures without compromising performance or longevity. This rating reduces the need for additional protective measures in many applications.

This level of protection is critical for maintaining the drive's internal components and preventing premature failure due to environmental contaminants.


How does this drive contribute to energy efficiency in HVAC systems?

The VLT HVAC Drive adjusts motor speed to precisely match the actual demand, unlike fixed-speed systems. This variable speed operation significantly reduces energy consumption.

By slowing down fans and pumps when full output is not needed, the drive capitalizes on the significant power savings associated with reduced motor speed. This leads to lower electricity bills and a reduced carbon footprint.

Intelligent control algorithms further optimize motor performance, ensuring maximum efficiency across a wide range of operating conditions and load variations.


What are the typical communication protocols supported by the FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX?

This drive series typically supports common industrial fieldbus protocols for seamless integration into building automation systems. Examples include BACnet and Modbus.

Specific communication modules may be required to enable certain protocols, allowing for remote monitoring, control, and parameter adjustment. Check the product options for exact compatibility.

These protocols are essential for centralizing HVAC system management, enabling data logging, and facilitating advanced control strategies within a larger facility management system.


How can I program the Danfoss FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX for a specific fan application?

Access the drive's programming menu and navigate to the application-specific parameters for fan control. Select the appropriate fan mode.

Configure essential settings such as minimum and maximum motor speeds, ramp times for acceleration and deceleration, and any specific control logic required, like PID control for pressure or temperature.

Ensure motor data (e.g., power, voltage, frequency, current) is accurately entered to optimize performance and protection. Save the parameters and perform a test run under load.


What are the power and current ratings of the DANFOSS FC-101P37KT4E5AH2XAXXXXSXXXXAXBXCXXXXDX?

The drive has a substantial power rating of 37 kilowatts (kW), suitable for demanding motor loads. It can handle a rated current of 73 amperes (A).

These specifications indicate its capability to drive larger HVAC components such as significant pumps or fans in commercial or industrial settings. Ensure your connected motor's nameplate data falls within these limits.

The 480V, 3-phase input voltage is standard for many industrial power systems, making this drive compatible with common power supplies in its intended market.


What maintenance is recommended for this VLT HVAC Drive?

Regularly inspect the drive's enclosure for dust and debris, cleaning as necessary to ensure proper ventilation and prevent overheating. Check all electrical connections for tightness.

Periodically review the drive's event log for any recorded faults or warnings that might indicate underlying issues. Perform software updates as recommended by Danfoss to ensure optimal performance and security.

While these drives are robust, a proactive maintenance approach, including visual inspections and log reviews, can prevent unexpected downtime and extend the operational life of the unit.