DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX 1.1kW 500V Three Phase Automation Inverter

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$956.00
zhongpingtech

The DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX 1.1kW 500V Three Phase Automation Inverter is a high-performance variable frequency drive engineered for demanding industrial automation applications. This inverter excels in providing precise motor control, energy efficiency, and robust operational reliability. Its core advantages lie in its advanced control algorithms, comprehensive protection features, and flexible configuration options, making it a superior choice for optimizing electromechanical processes across various sectors. Key technical parameters include a power rating of 1.1kW, an input voltage of 500V, and a three-phase power supply, all contributing to its suitability for substantial industrial loads.


DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX: Specifications at a Glance


| Parameter             | Value                                                                 |

| :-------------------- | :-------------------------------------------------------------------- |

| Model Number      | FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX                                |

| Power Rating      | 1.1 kW                                                                |

| Input Voltage     | 500 V                                                                 |

| Phase             | Three Phase                                                           |

| Enclosure Type    | Likely IP21/IP40 or higher, depending on exact suffix (XGCXXXSXXXXA) |

| Control Method    | Advanced Vector Control, V/f Control                                  |

| Communication     | Option for various fieldbus protocols (e.g., Profibus, Modbus)        |

| Braking Unit      | Integrated or optional depending on specific configuration            |

| Filter Options    | Integrated or optional EMC filters                                    |


Core Features & Market Positioning


The DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX distinguishes itself through its sophisticated control capabilities, particularly its advanced VVCplus (Variable Voltage and Vector Control) technology. This enables superior dynamic performance and precise speed regulation, even under fluctuating load conditions, setting it apart from standard V/f control drives. Its robust design and comprehensive protection mechanisms, including thermal overload, short circuit, and overvoltage protection, ensure exceptional operational safety and longevity, positioning it as a reliable workhorse in challenging industrial environments. The flexibility offered by its modular design and extensive communication options further enhance its market appeal, allowing for seamless integration into diverse automation architectures.


Key Application Scenarios


This DANFOSS automation inverter is ideally suited for a wide array of industrial applications where precise motor speed and torque control are paramount. It excels in pump and fan control, significantly improving energy efficiency by matching motor speed to system demand, thus reducing power consumption. Its advanced control algorithms make it perfect for conveyor systems, extrusion machines, and mixers, where consistent speed and torque are critical for product quality and throughput. Furthermore, its robust performance and high overload capacity lend themselves to applications in the material handling, packaging machinery, and general industrial automation sectors, where reliability and efficiency are non-negotiable.


Practical System Integration Guidance


Integrating the DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX involves careful consideration of power and control wiring. The inverter requires a stable 500V three-phase power supply, with appropriate circuit breakers and isolation switches installed for safety. For optimal performance and EMC compliance, shielded motor cables and proper grounding techniques must be employed. The commissioning process typically involves setting basic motor parameters, such as rated voltage, current, and frequency, as well as configuring speed references and I/O assignments. Utilizing the Danfoss MCT 10 software simplifies parameterization and diagnostics, allowing for efficient setup and optimization of the drive's performance within the broader automation system.


Operation and Risk Mitigation


Operating the DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX safely and efficiently requires adherence to established industrial practices. Always ensure the drive is properly installed in a well-ventilated environment, away from excessive dust, moisture, and extreme temperatures, to prevent overheating and component failure. Before performing any maintenance or wiring adjustments, disconnect all power sources and verify that the DC bus capacitors have fully discharged. Common fault codes, such as 'Overcurrent' (e.g., A1-xx) or 'Overload' (e.g., B1-xx), typically indicate issues with the motor, load, or drive parameters that require immediate investigation according to the product manual.


Scalability & Long-Term Value


The DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX offers significant long-term value through its inherent scalability and compatibility. Its modular design allows for the addition of option modules for advanced communication protocols, such as Profinet or EtherNet/IP, and expanded I/O capabilities, enabling seamless integration with evolving Industry 4.0 initiatives and IIoT platforms. This adaptability ensures that the inverter can remain a relevant component in sophisticated automation systems for years to come, supporting future upgrades and expansions without necessitating a complete system overhaul. The robust construction and Danfoss's reputation for reliability further underscore its long-term investment appeal.


Frequently Asked Questions


What are the primary benefits of using the DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX?


This inverter provides superior motor control accuracy. It offers significant energy savings by optimizing motor speed. The drive ensures operational reliability and longevity.


Its advanced features reduce mechanical stress on equipment. This leads to extended system lifespan. It offers robust protection against electrical faults.


The DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX boasts high efficiency ratings. This minimizes operational costs over time. It supports flexible integration into diverse automation systems.


How do I perform basic parameter setup for this inverter?


Connect the inverter to a stable 500V three-phase power supply. Ensure proper grounding and motor connections are secure. Use the control panel or Danfoss MCT 10 software for setup.


Navigate to the motor data menu. Input essential motor parameters like rated voltage, current, and speed. Adjust control mode settings (e.g., VVCplus) as per application needs.


Configure digital and analog I/O for speed commands and feedback. Set up any required protection limits and alarm thresholds. Save all parameters before enabling the drive.


What are common fault codes for the FC-302 and their meanings?


Fault code A1-xx typically indicates an overcurrent condition. This can be due to a rapid acceleration or a motor short circuit. Check motor windings and acceleration ramps.


Fault code B1-xx signifies an overload situation. This usually means the motor is drawing more current than its rated capacity for an extended period. Verify the mechanical load on the motor.


Other common faults include E1-xx for overvoltage and F1-xx for motor overtemperature. Refer to the specific DANFOSS FC-302 manual for detailed troubleshooting steps.


Can this inverter be used with standard asynchronous motors?


Yes, the DANFOSS FC-302P1K1T5E20H2XGCXXXSXXXXAXBXCXXXXDX is designed for use with standard three-phase asynchronous induction motors. Its advanced control modes optimize performance for these motor types. Ensure motor nameplate data is correctly entered.


The VVCplus control method provides excellent torque control. This is beneficial for applications with varying loads. It ensures smooth operation and precise speed maintenance.


Always verify motor compatibility and nameplate details. Proper motor selection and parameterization are crucial for optimal performance and drive longevity.


What is the recommended ambient operating temperature range?


The typical recommended ambient operating temperature range is -10°C to +40°C (14°F to 104°F). This range may vary slightly depending on the specific enclosure and cooling configuration. Ensure adequate ventilation.


For operation above +40°C, derating of the drive's current capacity is necessary. Consult the product manual for specific derating curves. Maintaining the correct temperature prevents thermal stress.


Operating outside the specified temperature range can lead to premature failure. Avoid installations in direct sunlight or near heat sources. Proper thermal management is key.


How do I connect a remote control panel to the FC-302?


Remote control panels are typically connected via serial communication interfaces. These can include RS-485 for Modbus RTU or specific fieldbus protocols. Refer to the option module specifications.


Ensure the correct cable type and pin assignment are used for the connection. Install terminators if required for the communication bus. Configure the drive's communication parameters to match the panel.


Once connected and configured, the remote panel allows for motor control, parameter adjustments, and status monitoring from a distance. This enhances operational flexibility and safety.


What are the key differences between VVCplus and V/f control?


VVCplus (Variable Voltage and Vector Control) offers superior dynamic response and precise torque control. It is ideal for applications requiring high performance and accurate speed regulation. This method senses motor flux and current.


V/f control maintains a constant ratio between voltage and frequency. It is simpler and suitable for basic applications like pumps and fans with stable loads. It offers less precise torque control.


VVCplus provides better motor performance under varying loads. It allows for rapid changes in speed and torque commands. V/f control is more sensitive to load fluctuations.


What is the role of EMC filtering with this inverter?


EMC filters reduce electromagnetic interference generated by the inverter. This prevents disruption to other electronic equipment in the vicinity. They are crucial for compliance with EMC regulations.


Proper EMC filtering ensures the inverter operates without causing noise on power lines. It also protects the inverter itself from external electrical noise. This contributes to system stability and reliability.


The type of EMC filter required depends on the installation environment and applicable standards. Consult the product manual for recommendations on filter selection and installation.


How can I achieve energy savings with the DANFOSS FC-302?


Employ the inverter's variable speed capabilities to match motor output to process demand. This significantly reduces energy consumption compared to fixed-speed operation. Optimize acceleration and deceleration ramps.


Utilize the built-in energy-saving functions if available. These functions can further reduce energy usage under light load conditions. Ensure motor and load are correctly parameterized.


Regularly monitor the drive's energy consumption metrics. Fine-tune parameters based on operational data for continuous improvement. Proper setup is key to maximizing savings.


What safety precautions are essential during installation and maintenance?


Always ensure the main power supply is disconnected before working on the inverter. Verify that the DC bus capacitors are discharged before touching any internal components. Use appropriate personal protective equipment.


Follow local electrical codes and regulations for wiring and grounding. Ensure the inverter is installed in an accessible location for future maintenance. Clearly label all circuit breakers.


Never bypass safety interlocks or protective functions. If unsure about any procedure, consult the official DANFOSS documentation or a qualified technician. Safety is paramount.

Menu