Siemens 3RW5245-6AC14 SIRIUS High Performance Motor Soft Starter 315A 160kW

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3RW5245-6AC14
  • HS: 85369010
Availability:In Stock
$3877.11
zhongpingtech

The Siemens 3RW5245-6AC14 SIRIUS High Performance Motor Soft Starter is engineered for demanding industrial applications, offering smooth acceleration and deceleration to protect motor infrastructure and optimize energy consumption. This advanced soft starter boasts integrated bypass functionality, reducing energy loss during full-speed operation and extending component lifespan. With a robust 315A current rating and a powerful 160kW motor capacity, it delivers exceptional performance in critical processes. Key advantages include its compact design, simplified setup, and comprehensive protection features, positioning it as a superior choice for variable torque loads in sectors like material handling, pumps, and fans.


Product Specifications


| Parameter                     | Value                                    |

| :---------------------------- | :--------------------------------------- |

| Product Type                  | Motor Soft Starter                       |

| Series                        | SIRIUS 3RW5                            |

| Model Number                  | 3RW5245-6AC14                            |

| Rated Operational Voltage     | 200-480 V AC                             |

| Rated Operational Current     | 315 A                                    |

| Motor Power (Standard)        | 160 kW at 400 V                          |

| Control Voltage               | 110-250 V AC/DC                          |

| Number of Phases              | 3                                        |

| Switching Device              | Thyristor                                |

| Integrated Bypass             | Yes                                      |

| Communication Interface       | Optional (e.g., PROFINET)                |

| Protection Functions          | Overload, Short circuit, Ground fault, Phase imbalance |

| Enclosure Rating              | IP20                                     |

| Dimensions (H x W x D)        | 360 x 220 x 257 mm                       |

| Ambient Temperature (Operation) | -25 to +60 °C                            |


Core Features & Market Positioning


The Siemens 3RW5245-6AC14 stands out in the industrial motor control market due to its high-performance thyristor-based technology, providing precise control over motor starting and stopping. The integrated bypass contactor is a significant differentiator, minimizing energy loss during continuous operation and thereby reducing operational costs and heat generation. This feature, combined with its advanced protection algorithms, ensures a longer lifespan for the motor and connected equipment, making it a cost-effective and reliable solution for critical industrial processes. Its robust build and comprehensive safety features solidify its position as a premium offering for users prioritizing performance and durability.


Key Application Scenarios


This Siemens soft starter is ideally suited for applications requiring smooth, controlled motor starts, significantly reducing mechanical stress on equipment. Common scenarios include centrifugal pumps and fans where variable torque loads are prevalent, preventing water hammer effects and ensuring stable system operation. It's also highly effective in conveyor systems and material handling equipment, providing gentle acceleration to prevent product damage and maintain process integrity. The 160kW capacity makes it suitable for large industrial machinery, including compressors and crushers, where high starting currents need to be managed to prevent grid disturbances.


Practical System Integration Guidance


Integrating the Siemens 3RW5245-6AC14 into existing control systems is streamlined due to its standard dimensions and flexible wiring options. For installation, ensure a stable, vibration-free environment with adequate ventilation, adhering to the specified ambient temperature range of -25 to +60 °C. Wiring involves connecting the main power terminals to the motor and power supply, with control voltage inputs for parameterization and operation. The device supports various communication protocols, allowing seamless integration with SCADA systems and PLCs for remote monitoring and control, enhancing operational efficiency.


Operation and Risk Mitigation


Safe operation of the 3RW5245-6AC14 is paramount, with built-in protection against overload, short circuits, ground faults, and phase imbalances, minimizing the risk of motor damage. During commissioning, proper parameterization of starting torque, ramp time, and trip classes is crucial to match the motor's characteristics and load requirements. Common troubleshooting involves checking for tripped protection relays, ensuring correct voltage supply, and verifying parameter settings. For instance, persistent overload faults may indicate an undersized motor or an excessively long start ramp for the load.


Scalability & Long-Term Value


The Siemens 3RW5245-6AC14 offers significant long-term value through its compatibility with the broader Siemens SIRIUS ecosystem and its inherent adaptability. It can be easily integrated with other SIRIUS devices, such as contactors and overload relays, to build comprehensive motor control solutions. Furthermore, its support for advanced communication interfaces like PROFINET enables seamless integration into Industrial IoT (IIoT) platforms, allowing for predictive maintenance, remote diagnostics, and data-driven optimization of motor performance. This future-proofs the investment, ensuring the soft starter remains a valuable component in evolving digital factory environments.


FAQs


1. What are the main benefits of using the Siemens 3RW5245-6AC14?


It provides smooth motor acceleration, reducing mechanical stress. The integrated bypass minimizes energy loss at full speed. Comprehensive protection features enhance equipment longevity.


2. How does the integrated bypass feature work and why is it important?


The bypass contactor activates once the motor reaches full speed. This bypasses the thyristors, reducing heat and energy consumption. It significantly lowers operational costs and extends the life of the soft starter components.


3. What motor power can the Siemens 3RW5245-6AC14 handle?


This soft starter is rated for a motor power of up to 160 kW at 400V. It can handle a rated operational current of 315A. Ensure the motor's nominal current does not exceed the starter's rating.


4. Can this soft starter be used for direct-on-line (DOL) applications?


No, it is designed for soft starting, not as a direct-on-line replacement. Its purpose is to control the starting current and torque gradually. Using it as a DOL starter would bypass its primary protective and control functions.


5. What types of loads is this soft starter best suited for?


It is ideal for variable torque loads like pumps and fans. Conveyor systems and material handling equipment benefit greatly. Applications requiring gentle acceleration and deceleration are prime uses.


6. How is the Siemens 3RW5245-6AC14 installed and commissioned?


Installation requires adequate ventilation and stable mounting. Wiring involves connecting power and control circuits as per the manual. Commissioning requires careful parameter setting for ramp time and torque.


7. What communication capabilities does this soft starter offer?


Optional communication modules allow integration with systems like PROFINET. This enables remote monitoring and control via PLC or SCADA. It facilitates data exchange for diagnostics and IIoT integration.


8. What are the key protection functions included in the 3RW5245-6AC14?


It protects against motor overload and short circuits. Ground fault and phase imbalance detection are also included. These functions prevent damage and ensure operational safety.


9. How does this soft starter compare to a variable frequency drive (VFD)?


Soft starters control voltage for ramp-up, while VFDs control frequency and voltage for speed control. Soft starters are simpler and typically less expensive for basic start/stop control. VFDs offer broader speed regulation capabilities and energy savings at partial loads.


10. What is the typical lifespan and maintenance for this device?


With proper installation and operation, the lifespan is extensive due to reduced component stress. Maintenance primarily involves periodic checks of connections and parameter verification. The bypass feature also contributes to longevity by reducing thyristor wear.