Siemens 3VA1150-4EE32-0AA0 Molded Case Circuit Breaker (MCCB) 50A 3P 36kA

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3VA1150-4EE32-0AA0
  • HS: 85362020
Availability:In Stock
$121.87
zhongpingtech

The Siemens 3VA1150-4EE32-0AA0 is a 50A, 3-pole, 36kA molded case circuit breaker (MCCB) engineered for robust electrical protection in demanding industrial environments. This MCCB offers exceptional reliability, compact design, and advanced tripping characteristics, making it a superior choice for safeguarding power distribution systems. Its inherent thermal-magnetic tripping mechanism ensures precise overload and short-circuit protection, while its high breaking capacity of 36kA provides a significant safety margin against fault currents. Designed for ease of installation and integration, the Siemens 3VA1150-4EE32-0AA0 is a cornerstone for secure and efficient electrical infrastructure.


Product Specifications


| Parameter               | Value                     |

| :---------------------- | :------------------------ |

| Product Type            | Molded Case Circuit Breaker (MCCB) |

| Manufacturer            | Siemens                   |

| Model Number            | 3VA1150-4EE32-0AA0        |

| Rated Current (In)      | 50A                       |

| Number of Poles         | 3                         |

| Breaking Capacity (Icu) | 36kA                      |

| Trip Unit Type          | Thermal-Magnetic          |

| Voltage Rating          | 400/415V AC               |

| Mounting Type           | Fixed, front/rear connection |

| Dimensions (H x W x D)  | 157.5mm x 76.2mm x 70mm   |


Core Features & Market Positioning


The Siemens 3VA1150-4EE32-0AA0 MCCB distinguishes itself through its robust construction and adherence to stringent international standards, including IEC 60947-2. Its compact form factor optimizes panel space, a critical consideration in modern electrical installations. The thermal-magnetic trip unit offers reliable protection against overloads and short circuits, featuring adjustable thermal overload settings for enhanced application flexibility. This combination of reliable performance, space efficiency, and adaptability positions the 3VA1150 series as a leading solution for general power distribution and industrial applications where dependable circuit protection is paramount.


Key Application Scenarios


This Siemens MCCB is ideally suited for a broad spectrum of industrial and commercial applications. It serves as essential protection in motor control centers (MCCs), main distribution boards, and sub-distribution panels within manufacturing plants, data centers, and building management systems. The 36kA breaking capacity ensures safety in areas with potentially high fault currents. Its suitability for use in various climates and challenging environments underscores its versatility in protecting critical equipment and ensuring operational continuity.


Practical System Integration Guidance


Integrating the Siemens 3VA1150-4EE32-0AA0 into existing electrical systems is straightforward due to its standardized dimensions and flexible connection options, including front and rear wiring terminals. Ensure compliance with local electrical codes and standards during installation. For fixed installations, secure mounting on a DIN rail or a panel with appropriate hardware is recommended. Proper torque must be applied to the terminal connections to prevent overheating and ensure a reliable electrical interface.


Operation and Risk Mitigation


The primary function of the 3VA1150-4EE32-0AA0 is to protect electrical circuits and equipment from damage caused by overcurrents and short circuits. In the event of a fault, the thermal element responds to sustained overloads by tripping the breaker, while the magnetic element reacts instantaneously to high short-circuit currents. Regular visual inspections for signs of damage or wear, along with periodic functional testing, are crucial for maintaining optimal performance and mitigating risks.


Scalability & Long-Term Value


While the 3VA1150-4EE32-0AA0 is a fixed-configuration MCCB, Siemens offers a comprehensive range of accessories and related products that enhance system scalability. This includes auxiliary and signaling contacts for remote monitoring, shunt trip coils for remote disconnection, and undervoltage releases for protection against voltage fluctuations. Its robust design and Siemens' commitment to quality ensure long-term operational reliability and a reduced total cost of ownership, supporting stable power distribution infrastructure.


Frequently Asked Questions


What is the rated current of the Siemens 3VA1150-4EE32-0AA0?

The rated current for this specific model is 50 Amperes. This defines the maximum continuous current the breaker can safely handle.


This current rating is critical for matching the breaker to the load it protects. Overcurrents above 50A will trigger protective actions.


Ensuring the rated current aligns with circuit demand prevents nuisance tripping and safeguards against thermal damage to conductors.


What is the breaking capacity of this MCCB?

This MCCB features a breaking capacity of 36 kA (kiloamperes). This is the maximum fault current it can safely interrupt.


A higher breaking capacity provides superior protection against severe short circuits. It ensures the breaker can safely de-energize the circuit without damage.


This 36kA rating is suitable for many industrial applications where fault levels can be significant.


How many poles does the Siemens 3VA1150-4EE32-0AA0 have?

The Siemens 3VA1150-4EE32-0AA0 is a 3-pole circuit breaker. This means it can simultaneously disconnect all three phases of a three-phase power system.


Utilizing a 3-pole breaker is essential for balanced three-phase loads to ensure complete isolation during faults. It prevents single-phasing issues.


Protection and isolation of all live conductors are achieved, enhancing safety and preventing damage to three-phase equipment.


What type of trip unit does this breaker use?

This MCCB utilizes a thermal-magnetic trip unit. It provides protection against both overload and short-circuit conditions.


The thermal element protects against sustained overcurrents, while the magnetic element provides rapid response to high fault currents. This dual protection is standard for MCCBs.


This reliable technology offers a balance of protection and cost-effectiveness for general-purpose circuit protection applications.


Is the Siemens 3VA1150-4EE32-0AA0 suitable for motor protection?

Yes, it can be used for basic motor protection with its overload and short-circuit capabilities. Adjustments may be needed for specific motor starting characteristics.


However, for specialized motor protection with features like phase unbalance or ground fault, more advanced electronic trip units might be preferred. It offers essential safety features.


The 50A rating and 36kA breaking capacity provide a solid foundation for protecting motors from common electrical faults.


What are the dimensions of this circuit breaker?

The typical dimensions for this MCCB are approximately 157.5mm in height, 76.2mm in width, and 70mm in depth. These are standard for its class.


Its compact size is advantageous for panel builders, allowing for more efficient use of space in electrical enclosures. This aids in dense installations.


Always verify exact dimensions against panel layout drawings for precise integration into your electrical distribution system.


What are the mounting options for this MCCB?

This breaker is typically designed for fixed mounting with options for front or rear connection. It is commonly mounted on a DIN rail or directly onto a panel.


Ensuring secure mounting is critical for maintaining electrical integrity and preventing vibration-induced issues in industrial settings. Proper hardware is key.


Installation should follow manufacturer guidelines and local electrical codes for safe and reliable operation in its intended environment.


What international standards does this breaker comply with?

This Siemens MCCB complies with international standards such as IEC 60947-2. This ensures a high level of safety and performance.


Adherence to these standards guarantees the breaker's suitability for global markets and provides confidence in its protective capabilities. It signifies quality.


Verification against specific project requirements or regional standards may still be necessary to ensure full compliance.


Can this breaker be remotely operated?

While the standard thermal-magnetic version does not offer direct remote operation, accessories are available. These can include shunt trip units or auxiliary contacts.


These accessories allow for integration into control systems for remote tripping or status monitoring, enhancing system automation. It expands functionality.


The addition of such accessories enables a degree of remote control and system integration for enhanced operational flexibility.


What is the typical voltage rating for this model?

The typical voltage rating for this MCCB is 400/415V AC. This is standard for industrial power distribution in many regions.


This voltage rating signifies its suitability for common industrial and commercial three-phase power systems. It ensures safe operation.


Always confirm the system voltage matches the breaker's rating to prevent damage or hazardous conditions during operation.

Menu