The DANFOSS iC2-30FA3N04-31A0E20F2+ACBC 15kW 31A 3AC 480V iC2-30 F2 Inverter is a robust and versatile variable frequency drive engineered for demanding industrial applications. This unit excels in providing precise motor control, energy savings, and enhanced system reliability. Its core advantages lie in its advanced control algorithms, compact design, and comprehensive protection features, making it a superior choice for various automation tasks. The iC2-30 F2 inverter boasts a power rating of 15kW, a maximum output current of 31A, operates on a 3-phase AC 480V supply, and features an F2 enclosure.


Product Specifications


| Parameter             | Value                                   |

| :-------------------- | :-------------------------------------- |

| Model                 | iC2-30FA3N04-31A0E20F2+ACBC             |

| Power Rating          | 15 kW                                   |

| Output Current        | 31 A                                    |

| Input Voltage         | 3 AC 480 V                              |

| Enclosure Type        | F2                                      |

| Control Type          | iC2-30 F2                               |

| Harmonic Limiter      | Included (ACBC)                         |


Core Features & Market Positioning


The DANFOSS iC2-30FA3N04-31A0E20F2+ACBC distinguishes itself through its superior motor control capabilities, offering both V/f and advanced vector control modes for optimal performance across a wide range of motor types and applications. Its integrated harmonic limiter (ACBC) is a significant differentiator, ensuring compliance with stringent power quality standards and reducing the need for external filters, thereby simplifying installation and reducing costs. This inverter is positioned as a highly reliable and efficient solution for medium-power industrial drives, competing effectively with other premium brands by offering a compelling balance of advanced features, robust build quality, and user-friendly operation. The F2 enclosure provides enhanced protection against environmental factors, crucial for longevity in harsh industrial settings.


Key Application Scenarios


This DANFOSS iC2-30 inverter is exceptionally well-suited for applications requiring precise speed and torque control, such as conveyor systems, pumps, fans, and material handling equipment within manufacturing and processing industries. Its ability to handle 480V three-phase power makes it ideal for North American and other regions with similar power grids. The integrated harmonic mitigation is particularly valuable in applications where power quality is critical, such as food and beverage processing, pharmaceutical manufacturing, and water treatment facilities, preventing disturbances to other sensitive equipment. Users frequently search for drives capable of managing variable loads and delivering energy efficiency, making this inverter a prime candidate for HVAC systems and general industrial machinery.


Practical System Integration Guidance


Integrating the DANFOSS iC2-30FA3N04-31A0E20F2+ACBC requires careful attention to power and control wiring. The unit accepts 3-phase 480V AC input. Ensure the power supply is properly grounded and that appropriate circuit protection (fuses or breakers) is installed upstream. For control wiring, utilize shielded cables to minimize electromagnetic interference, particularly for analog inputs/outputs and digital signals. Parameter programming is accessed via the integrated keypad or through optional communication modules. A common setup involves configuring motor data (rated power, voltage, current, frequency, pole count) and desired control mode (V/f or vector). For basic V/f control, setting the acceleration and deceleration ramps to suit the driven load is crucial.


Operation and Risk Mitigation


Operating the DANFOSS iC2-30FA3N04-31A0E20F2+ACBC involves understanding its primary functions and safety protocols. Always ensure the drive is de-energized before performing any wiring or maintenance. Overcurrent and overvoltage faults are common issues that can arise from incorrect parameter settings or unstable power supplies; consult the manual for specific trip codes and resolution steps. The integrated protection features, including thermal overload and short-circuit protection, are designed to safeguard the motor and the drive itself. Regular inspection of connections and environmental conditions within the F2 enclosure will help mitigate potential operational risks and ensure continuous, reliable performance.


Scalability & Long-Term Value


The DANFOSS iC2-30 F2 inverter offers significant long-term value through its inherent scalability and integration capabilities. While not explicitly detailed in readily available specifications, Danfoss drives typically support various communication protocols (e.g., Modbus, Profibus) via optional communication cards, allowing seamless integration into existing SCADA or PLC systems for advanced monitoring and control. This connectivity is essential for implementing IIoT strategies and predictive maintenance programs. The robust design and comprehensive protection features also contribute to a longer operational lifespan, reducing the total cost of ownership and providing a reliable foundation for future automation upgrades.


Frequently Asked Questions (FAQs)


1. What are the primary benefits of the DANFOSS iC2-30FA3N04-31A0E20F2+ACBC?

This inverter offers precise motor control for efficiency. It provides integrated harmonic limitation for better power quality. The robust F2 enclosure ensures durability in industrial environments.


2. How do I perform basic parameter setup for this iC2-30 F2 inverter?

Start by entering the motor's rated voltage and current. Configure the desired control mode, either V/f or vector control. Set acceleration and deceleration times to match the application's load profile.


3. What are common troubleshooting steps for fault codes on the iC2-30 F2?

First, identify the specific fault code displayed on the keypad. Consult the product manual for the meaning of the code and recommended actions. Often, clearing the fault after addressing the underlying cause resolves the issue.


4. Can the DANFOSS iC2-30 inverter be controlled remotely?

Yes, this drive supports remote control through various communication protocols. Optional communication modules can be added for integration with fieldbus networks. This enables PLC or SCADA system supervision.


5. What is the purpose of the ACBC in the product name?

ACBC denotes the integrated harmonic limiter. This feature actively reduces harmonic distortion on the mains supply. It ensures compliance with power quality regulations and protects sensitive equipment.


6. What is the maximum motor size this 31A inverter can drive?

This 31A inverter is rated for a 15kW motor at 480V. It is crucial to match the motor's nameplate data with the drive's output capabilities. Always refer to the motor and drive manuals for precise compatibility.


7. How does the F2 enclosure protect the inverter?

The F2 enclosure offers a higher degree of protection against dust and moisture. It is designed for industrial environments where environmental conditions can be harsh. This enhances the drive's reliability and lifespan.


8. What types of motors can be controlled by the iC2-30 F2?

The iC2-30 F2 inverter can control standard AC induction motors. It supports both V/f control for simpler applications and vector control for enhanced dynamic performance. This versatility suits many industrial needs.


9. Is this DANFOSS inverter suitable for pump and fan applications?

Absolutely, the iC2-30 F2 is highly suitable for variable torque loads like pumps and fans. Its precise speed control leads to significant energy savings. The integrated features optimize performance for these systems.


10. Where can I find the full technical manual for the iC2-30FA3N04-31A0E20F2+ACBC?

The complete technical manual is typically available on the Danfoss official website. Searching for the exact model number will lead to the relevant product documentation. This manual contains detailed specifications and operational procedures.